ESP Selection Design

Select New Single Branch Model


Build a Simple complation using t
he completion icon, tubing icon a
nd with an outlet node. Select the
Vertical Completion button and pl
ace it the single branch window.
Double click VertWell_1
 Enter 3625 psia in the Static P
ressure text box
 Enter 288 F in the Temperatur
e text box
 Select Well PI for Model Type
in the Completion Model field
 Select Liquid PI and enter 12.
4 stb/d/psi in the text box
 Click Use nonlinear correctio
n below bubble point
 Click OK
Define the Black Oil Fluid
Model by Setup > Black
Oil and click
 Select the Black Oil Properties t
ab
 In the Fluid Name field, enter ES
P
 In the Stock Tank Properties fiel
d, enter the following parameter
s:
 WC : 90%
 GOR : 449 scf/STB
 Gas SG : 0.984
 Water SG : 1.026
 API : 30
 In the Calibrating Data at Bubbl
e Point field, enter the following
parameters :
 Pressure : 2216 psia
 Temperature : 288 F
 Sat. Gas : 0.54 cP
 In the Solution Gas Correlation f
ield, select Lasater from the dro
p down menu
 Click OK
Double click Tubing_1
 In the Tubing_Tubing_1 window
, in the Preferred Tubing Model f
ield, select Simple Model from t
he drop down menu
 In the Ambient Temperature text
box, enter 68 F.
 In the Tubing section (#1 requir
ed, others optional) field, in the
Tubing #1 row and the MD colu
mn text, enter 2863
 In the Tubing #1 row and the ID
column text box, enter 3.958
 In the Tubing #2 row and the MD
column text box, enter 2863
 In the Tubing #2 row and the ID
column text box, enter 8.681
 In the Perforations field, MD text
box, enter 9393 ft from the drop
down menu and enter 288 F in t
he Reservoir Temperature text b
ox.
 Click OK
Select Setup > Flow Corr
elation and Click
In the Flow Correlation wi
ndow, in the Vertical Flow
(Multhiphase) field, select
Hagedorn & Brown for Co
rreclation and Click OK
Select Operation > Nodal
Analysis and Click
 In the Nodal Analysis window, i
n the Outlet Pressure text box, e
nter 250 psia
 Click Run Model
Result Nodal Analysis

Nodal After ESP


From Result Analysis We Can Select Pump Desig
n
Select Artificial Lift > ESP Design
 Enter the Pump Design Data par
ameters :
 Design Production Rate : 160
0 sm3/d
 Design Outlet Pressure : 8 ba
rg
 Pump setting depth : 2500 m
 ID : 8.681
 Design Frequency : 60 Hz
 Click Select Pump button
 Select Manufacturer to Reda
 Highlight and select the Reda H
N 13000 pump
 Click OK
Click the Calculate

Calculation Result
of ESP Design
It show by Pump P
erformance Plot an
d Pump Curv
Pump Performance Plot

Pump Curve
Install Pump
MD Pump Setting Depth, E
SP Data Automatically fill

Select Properties
To show result of ESP Design we must ru
n Nodal Analysis again
Nodal Before

Das könnte Ihnen auch gefallen