GEN 5 System Block Diagram
2 All Content Contained Herein Is Confidential And Proprietary Information of Fluidic Energy.
©2012 Fluidic Inc. | Proprietary and Confidential
GEN 6 System Block Diagram
3 All Content Contained Herein Is Confidential And Proprietary Information of Fluidic Energy.
©2012 Fluidic Inc. | Proprietary and Confidential
FLUIDIC APU BOARDS
A. GEN 5 UNIT
1. COMM CONTROL
2. IPM
3. PIT
B. GEN 6 UNIT
1. COMM CONTROL
2. EBMS
3. PBMS
4. NRG
4 All Content Contained Herein Is Confidential And Proprietary Information of Fluidic Energy.
©2012 Fluidic Inc. | Proprietary and Confidential
GEN 5 - COMM CONTROL Board
Primary Function:
To provide data processing and communication between FE Battery system and the
on-site and service tools peripherals.
Bus (-)
RECT PH
Cabinet FAN
GRID PH
SITE
INTERFACE
BATT (+)
CAN
RS 232 SYSTEM
HARNESS
RECT (+)
MEMORY CARD
5 All Content Contained Herein Is Confidential And Proprietary Information of Fluidic Energy.
©2012 Fluidic Inc. | Proprietary and Confidential
GEN 5 – IPM Board
Primary Function:
To control function of charge (BUCK) and discharge (BOOST) to all cells and communication through
LIN connection Module Address
FAN Cathode
LIN
Connection
Batt (-)
Batt (+)
Bus (-)
Bus (+)
6 All Content Contained Herein Is Confidential And Proprietary Information of Fluidic Energy.
©2012 Fluidic Inc. | Proprietary and Confidential
GEN 5 – PIT BOARD
Primary Function:
To control single function of charge and discharge at cells (as switching method per
termination)
Batt (+)
LIN
Connection
Anode, Cathode
and OEE Termination
Batt (-)
7 All Content Contained Herein Is Confidential And Proprietary Information of Fluidic Energy.
©2012 Fluidic Inc. | Proprietary and Confidential
GEN 6 - COMM CONTROL Board
Primary Function:
To provide data processing and communication between FE Battery system and the
on-site and service tools peripherals.
8 All Content Contained Herein Is Confidential And Proprietary Information of Fluidic Energy.
©2012 Fluidic Inc. | Proprietary and Confidential
GEN 6 – EBMS Board
Primary Function:
To control function of charge (BUCK) and discharge (BOOST) to all cells and communication through
LIN connection for Zink battery
FAN Cathode
LIN
Connection
Batt (-)
Batt (+)
Module
Address
Bus (-)
Bus (+)
9 All Content Contained Herein Is Confidential And Proprietary Information of Fluidic Energy.
©2012 Fluidic Inc. | Proprietary and Confidential
GEN 6 – PBMS Board
Primary Function:
To control function of charge (BUCK) and discharge (BOOST) to all cells and communication through
LIN connection for Lithium battery
Bus (+)
Bus (-)
Batt (-)
Peripheral
Harness
10 All Content Contained Herein Is Confidential And Proprietary Information of Fluidic Energy.
©2012 Fluidic Inc. | Proprietary and Confidential
GEN 6 – NRG Board
Primary Function:
As back power temporary during transition from charge to discharge
11 All Content Contained Herein Is Confidential And Proprietary Information of Fluidic Energy.
©2012 Fluidic Inc. | Proprietary and Confidential
12 All Content Contained Herein Is Confidential And Proprietary Information of Fluidic Energy.
©2012 Fluidic Inc. | Proprietary and Confidential