• DESIGN FACTORS
• CONSTRUCTION OF
• WATER WALL TUBE, SUPER HEATER, REAHEATER
0.5
0.4
Critical
0.3 Point
0.2
0
80 100 120 140 160 180 200 220 240
Pressure (Kg/cm2)
Density difference is the driving force for the steam and water
mixture.
Circulation takes place at such a rate that the driving force
and the frictional resistance are balance.
But as the pressure increases, the difference in density
between the water and steam reduces.
Hydrostatic head available may not be able to overcome
the frictional resistance for the flow corresponding to the
minimum requirement of cooling of water wall tubes.
Therefore, natural circulation is limited to Boiler with the drum
operating pressure around 175 kg/cm2
Above 175 kg/cm2 of pressure, circulation is to be assisted
with mechanical pumps, to overcome the frictional losses.
To regulate the flow through various tubes orifice plates are
used.
For the construction of boiler parts subjected to
pressure and their integral attachment, the designer
takes into account several factors
TUBE DETAILS
All economizer tube are of Ø 51mm X 5mm.
Located in the boiler back pass.
It is composed of three banks of 130 parallel
tube elements arranged in horizontal rows.
Each row is in line with the row above and
below.
All tube circuit originate from the inlet
header and terminate at the outlet header.
ECO OUTLET HDR
Ø406.4
ECO MIDDLE
BANK
ECO LOWER
BANK
REAR WALL
HGR TUBES SCREN TUBES
Ø63.5 Ø63.5
FURN FRONT
SUCTION WALL TUBES
MANIFOLD , Ø508 Ø51
FURN REAR
FURN SIDE WALL TUBES
WALL TUBES Ø51
Ø51
BCW PUMP
Divisional A Low
Panel Temperature
Section Section
The finishing section is located on the
horizontal gas path above the furnace rear
arch tubes.
The divisional panel section are located in
the furnace between the front wall and the
pendent platen section.
It consist of 6 front and 6 rear assemblies.
The low temperature section are located in
the furnace rear back pass above the
economizer section.
They are composed of 116 assemblies
spaced on across the furnace width.
The back pass wall and roof section forms
the side, front, rear wall and roof of the
vertical gas pass.
DIV PANEL O/L LINK MAIN
Ø 508, 2 NOS. STEAM
SH DESH Ø 508, 2
NOS.
HDR, Ø 406.4
SH ROOF O/L
BP UPPER REAR
HDR, Ø 273
SH CONN TUBES,
Ø 59
SH VERT PLATEN
Ø 47.63
Finishing
section
RH VERT PLATE
I/L HDR, Ø 457.
RH VERT PLATEN
O/L HDR, Ø 558.8