Dynamic Tiltmeter
Vibrating Wire Tiltmeters Selection

ELB0013A:
VWTM-6350: (Recommended) GEOCLIN:
Measuring Range:10 Measuring Range:10 Measuring Range):11
Accuracy: 0.1% FS Accuracy: 0.1% FS Accuracy:0.05% F.S.
Operation Temperature Operation Temperature Operation Temperature
Range:-20 C to +50 C Range:-20 to +80 C Range:-10 C to +60 C
Vibrating Wire Gage System

32-channel Display
Multiplexer Interface

Micro-10
Datalogger
Humidity Sensors Selection
HMP-45:
Operation Temperature Range: -40 to +60 °C
RH-Measuring Range: 0 to 100 %RH
RH Accuracy:±2 %RH (0...90 %RH);
±3 %RH (90...100 %RH)
Temperature-Measuring Range:-40...+60 °C
Temperature Accuracy:±0.2 °C

225-500-A:
Operation Temperature Range: -40 to +60 °C
RH-Measuring Range: 0 to 100 %RH
RH Accuracy:±2 %RH (0...90 %RH);
±3 %RH (90...100 %RH)
Temperature-Measuring Range:-40...+60 °C
Temperature Accuracy:±0.4 °C

MP-101A: (Recommeded)
Specification:
Operation Temperature Range: -40 to +60 °C
RH-Measuring Range: 0 to 100 %RH
RH Accuracy:±1 %RH (1...100 %RH)
Temperature-Measuring Range:-40...+60 °C
Temperature Accuracy:±0.3 °C
Precipitation Sensors Selection

260-2500: Model 370: RG-13: (Recommended)


Measuring Range:Unlimited Measuring Range:Unlimited Measuring Range:Unlimited
Resolution:0.25 mm Resolution:0.25 mm Resolution:0.2 mm
Height x Diameter:432x203 Height x Diameter:460x203 Height x Diameter:390x300
mm mm mm
Weight: 3.2 kg Weight: 2.7 kg Weight: 2.5 kg
Ultrasonic Wind Sensors Selection
WS-425: (Recommended)
Wind-speed Measuring Range:0-129 m/s
Wind- direction Measuring Range:0-360 °
Accuracy:Wind-speed: ± 0.135 m/s; Wind- direction: ± 2 °
Operation Temperature Range:-55° to +55° C

200-81000:
Wind-speed Measuring Range:0-40 m/s
Wind- direction Measuring Range:0-360 °
Wind-speed Accuracy: ± 1% rms ± 0.05 m/s (0 to 30 m/s)
± 3% rms (30 to 40 m/s)
Wind-direction Accuracy:± 2 ° (1 to 30 m/s)
± 5 ° (30 to 40 m/s)
Operation Temperature Range:-50 to +50 °C

Model CATI:
Wind-speed Measuring Range:0 - 50 m/s
Wind- direction Measuring Range:0-359 °
Accuracy:Wind-speed: ± 0.2 m/s; Wind- direction: ± 3 °
Operation Temperature Range:-40° to +70° C
Accelerometers Selection
EGCS-3A (Tri-axial): (Recommended)
Measuring Range:2g
Response Frequency:0.0150 Hz
Accuracy:±1 %F.S
Operation Temperature Range:-40 to 120

8392B2 (Tri-axial):
Measuring Range:2g
Response Frequency:0.1150 Hz
Accuracy:±2 %F.S
Operation Temperature Range:-40 to 120

3187D (Tri-axial):
Measuring Range:50g
Response Frequency:0.0150 Hz
Accuracy:±2 %F.S
Operation Temperature Range:-60 to 120