Sie sind auf Seite 1von 23

www.huawei.

com

• Guidance OSS Activity

HUAWEI TECHNOLOGIES CO., LTD.


2G 3G - Collect Dump

HUAWEI TECHNOLOGIES CO., LTD. Page 2


Collect 2G 3G Dump (CFGMML)
1.Objective
• Provide a guideline to collect 2G 3G CFGMML
2.Step to execute
• Login to M2000, choose Maintenance on Menu Bar then select MML
Command, and then select BSC/RNC (*if use M2000)
• Login to Web LMT BSC/RNC
• Run EXP CFGMML in MML Command at BSC/RNC which will collect

HUAWEI TECHNOLOGIES CO., LTD. Page 3


3.Step to collect in FTP
• Login to FTP BSC/RNC which will collect
• Path of each BSC :
/BSC6000/data/mbsc/bam/version_a/ftp/export_cfgmml or
/BSC6000/data/mbsc/bam/version_b/ftp/export_cfgmml
• Path of each RNC : /bam/version_a/ftp/export_cfgmml or
/bam/version_b/ftp/export_cfgmml

HUAWEI TECHNOLOGIES CO., LTD. Page 4


2G 3G - Collect Alarm

HUAWEI TECHNOLOGIES CO., LTD. Page 5


Collect 2G 3G Alarm
1.Objective
• Provide a guideline to collect 2G 3G Alarm
2.Step to collect
• Login to M2000, choose Monitor on Menu Bar then select Browse
Alarm Current or Browse Alarm History
• Select Basic Setting and then select Start Time & End Time
• Select Alarm Source and then choose Custom
• Select Add >NE and then choose Site/BTS >OK

HUAWEI TECHNOLOGIES CO., LTD. Page 6


2G 3G - Collect Original Counter

HUAWEI TECHNOLOGIES CO., LTD. Page 7


Collect 2G 3G Original Counter
1. Objective
• Provide a guideline to collect Original Counter
2. Step to execute
• Login to M2000, choose Performance and select Query Result on Menu Bar
• New Query and then choose object type of counter & object type RNC/site/cell/level

HUAWEI TECHNOLOGIES CO., LTD. Page 8


3. Choose the Other Tab >Select start time & end time and then Query(.xls format) or Export(.csv
format)

HUAWEI TECHNOLOGIES CO., LTD. Page 9


2G 3G - Rmv Add Neighbour Relation

HUAWEI TECHNOLOGIES CO., LTD. Page 10


2G – RMV ADD Neighbour Relation
1. Objective
• Provide a guideline to retune the Remove / Add Neighbour Relation Execution
2. Step to execute
• Login to M2000, choose Maintenance on Menu Bar then select MML Command, and then
select BSC(*if use M2000) 
• Login to Web LMT BSC
• Run EXP CFGMML in MML Command at BSC which will modified for backup data configuration
• Remove Neighbour Relation parameter by run this script :
RMV G2GNCELL:IDTYPE=BYNAME, SRC2GNCELLNAME=“xxx", NBR2GNCELLNAME=“xxx"; or
RMV G2GNCELL:IDTYPE=BYID, SRC2GNCELLID=xxx” NBR2GNCELLID=xxx;
• If Neighbour located at different BSC, should be add cell basic configuration at BSC Target
first by run this script : (If no different BSC, pass this step).
ADD GEXT2GCELL:EXT2GCELLID=xxx, EXT2GCELLNAME=“xxx", MCC="510", MNC="11",
LAC=xx, CI=xx, BCCH=xx, NCC=xx, BCC=xx;
• Add Neighbour Relation parameter by run this script :
ADD G2GNCELL:IDTYPE=BYNAME, SRC2GNCELLNAME=“xxx", NBR2GNCELLNAME=“xxx"; or
ADD G2GNCELL:IDTYPE=BYID, SRC2GNCELLID=xxx, NBR2GNCELLID=xxx;
3. REMARK
• Should correct for implementing new relation because the script impact to Hand Over
Performance.

HUAWEI TECHNOLOGIES CO., LTD. Page 11


3G – RMV ADD Neighbour Relation
1. Objective
• Provide a guideline to retune the Remove / Add Neighbour Relation Execution
2. Step to execute
• Login to M2000, choose Maintenance on Menu Bar then select MML Command, and then
select RNC (*if use M2000) 
• Login to Web LMT RNC
• Run EXP CFGMML in MML Command at RNC which will modified for backup data configuration
• Remove Neighbour Relation parameter by run this script :
RMV UINTRAFREQNCELL: RNCID=xxx, CELLID=xxx, NCELLRNCID=xxx, NCELLID=xxx;
RMV UINTRAFREQNCELL: RNCID=xxx, CELLID=xxx, NCELLRNCID=xxx, NCELLID=xxx;
• If Neighbour located at different RNC, should be add cell basic configuration at RNC Target
first by run this script : (If no different RNC, pass this step)
ADD UEXT3GCELL: NRncId=“xxx", CellId=“xxx", CellHostType=SINGLE_HOST, CellName=“xxx", CnOpGrpIndex=0, PScrambCode=“xxx",
BandInd=Band1, UARFCNUplinkInd=TRUE, UARFCNUplink="xxx", UARFCNDownlink="xxx", TxDiversityInd=FALSE, LAC="xxx",
CfgRacInd=REQUIRE, RAC="xxx", QqualminInd=FALSE, QrxlevminInd=FALSE, MaxAllowedUlTxPowerInd=FALSE, UseOfHcs=NOT_USED,
CELLCAPCONTAINERFDD=DELAY_ACTIVATION_SUPPORT-1&HSDSCH_SUPPORT-1&FDPCH_SUPPORT-1&EDCH_SUPPORT-
0&EDCH_2MS_TTI_SUPPORT-0&EDCH_2SF2_AND_2SF4_SUPPORT-0&EDCH_2SF2_SUPPORT-0&EDCH_2SF4_SUPPORT-0&EDCH_SF4_SUPPORT-
0&EDCH_SF8_SUPPORT-0&EDCH_HARQ_IR_COMBIN_SUPPORT-0&EDCH_HARQ_CHASE_COMBIN_SUPPORT-0&CPC_DTX_DRX_SUPPORT-
0&CPC_HS_SCCH_LESS_OPER_SUPPORT-0&HSPAPLUS_MIMO_SUPPORT-0&FLEX_MACD_PDU_SIZE_SUPPORT-
0&FDPCH_SLOT_FORMAT_SUPPORT-0&HSPAPLUS_DL_64QAM_SUPPORT-0, OVERLAYMOBILITYFLAG=NOT_FORBIDDEN, HARQPREACAP=Mode0,
CIO=0, EFACHSUPIND=FALSE, APFLAG=FALSE, VPLIMITIND=FALSE;

HUAWEI TECHNOLOGIES CO., LTD. Page 12


• Add Neighbour Relation parameter by run this script :
ADD UINTRAFREQNCELL: RNCID=xxx, CELLID=xxx, NCELLRNCID=xxx, NCELLID=xxx,
SIB11IND=TRUE, SIB12IND=FALSE, TPENALTYHCSRESELECT=D0, NPRIOFLAG=FALSE;
ADD UINTERFREQNCELL: RNCID=xxx, CELLID=xxx, NCELLRNCID=xxx, NCELLID=xxx,
SIB11IND=TRUE, SIB12IND=FALSE, TPENALTY HCSRESELECT=D0, BLINDHOFLAG=FALSE,
NPRIOFLAG=FALSE;
3. REMARK
• Should correct for implementing new relation because the script impact to Hand Over
Performance.

HUAWEI TECHNOLOGIES CO., LTD. Page 13


2G 3G - Reset Site/Cell & Block Site/Cell

HUAWEI TECHNOLOGIES CO., LTD. Page 14


2G - Reset Site/Cell & Block Site/Cell
1. Objective
• Provide a guideline to reset Site/Cell & Block Site/Cell
2. Step to execute (BTS Level)
• Login to M2000, choose Maintenance on Menu Bar then select MML Command, and then
select RNC (*if use M2000) 
• Login to Web LMT BSC
• Reset BTS parameter by run this script :
Reset BTS Sofware :
Reset BTSSoftware Level 3 : RST
BTS:TYPE=BTSSOFT,IDTYPE=BYNAME,BTSNAME=“xx",LEVEL=3-LEVEL;
Reset BTSSoftware Level 4 : RST
BTS:TYPE=BTSSOFT,IDTYPE=BYNAME,BTSNAME=“xx",LEVEL=4-LEVEL;
Reset BTS Hardware :
Reset BTS Hardware Site: RST
BTS:TYPE=BTSHW,SUBTYPE=SITE,IDTYPE=BYNAME,BTSNAME=“xx";
Reset BTS Hardware Cabinet: RST
BTS:TYPE=BTSHW,SUBTYPE=CABINET,IDTYPE=BYNAME,BTSNAME=“xx";
Reset BTS Hardware RFTRX: RST
BTS:TYPE=BTSHW,SUBTYPE=RFTRX,IDTYPE=BYNAME,BTSNAME=“xx";

HUAWEI TECHNOLOGIES CO., LTD. Page 15


3. Step to execute (Cell Level)
• Login to M2000, choose Maintenance on Menu Bar then select MML Command, and then
select RNC (*if use M2000) 
• Login to Web LMT BSC
• Reset Cell parameter by run this script :
Reset Cell Level 3 : RST GCELL:IDTYPE=BYNAME,CELLNAME=“xxx",LEVEL=3-LEVEL;
Reset Cell Level 4 : RST GCELL:IDTYPE=BYNAME,CELLNAME=“xxx",LEVEL=4-LEVEL;

HUAWEI TECHNOLOGIES CO., LTD. Page 16


3G - Reset Site/Cell & Block Site/Cell
1. Objective
• Provide a guideline to reset Site/Cell & Block Site/Cell
2. Step to execute (Site Level)
• Login to M2000, choose Topology and select Menu Topology on Menu Bar and then search
name of site (CTRL+F), Klik right on Topology NodeB > Maintenance Client (*if use M2000)
• Login to LMT NodeB
• Reset Site parameter by run this script :
RST NODEB:;

HUAWEI TECHNOLOGIES CO., LTD. Page 17


3. Step to execute (Cell Level)
• Login to M2000, choose Maintenance on Menu Bar then select MML Command, and then
select RNC (*if use M2000) 
• Login to Web LMT RNC
• Reset cell (Deactivate/Activate) parameter by run this script :
Deactivate Cell : DEA UCELL:CELLID=xxx;
Activate Cell :ACT UCELL:CELLID=xxx;
• Block/Unblock cell parameter by run this script :
Block Cell :BLK UCELL:CELLID=xxx;
Unblock Cell :UBL UCELL:UCELL:CELLID=xxx;

HUAWEI TECHNOLOGIES CO., LTD. Page 18


3G - FFT TEST (Fast Fourier Transformation)

HUAWEI TECHNOLOGIES CO., LTD. Page 19


FFT TEST (Fast Fourier
1. Objective Transformation)
• Provide a guideline to FFT Test
• From RAN13, we can do FFT test to check uplink interference with NodeB LMT
2. Step to FFT Test
•Run the MMLcommand LST RRU at selected NodeB and get the RRU cabinet No, subtrack No
and slot No.

•You can find FFT Frequecy Scan at Maintain Tab of NodeB LMT

HUAWEI TECHNOLOGIES CO., LTD. Page 20


3. Here are 3 models of FFT frequecy scan (High-resolution on-line frequency scan, Broadband on-
line frequency scan and Broadband off-line frequency scan. Mostly use High-resolution on-line
frequency scan and Broadband on-line frequency scan)
•High-resolution on-line frequency scan (Don’t break down service.Intraval should be set to
100KHz)

• Broadband on-line frequency scan (Don’t break down service.Intraval should be set to
200KHz)

HUAWEI TECHNOLOGIES CO., LTD. Page 21


• Broadband off-line frequency scan (Break down service. This will scan all uplink frequency
which RRU support. First block RRU board.

HUAWEI TECHNOLOGIES CO., LTD. Page 22


Thank you
www.huawei.com
Copyright©2013 Huawei Technologies Co., Ltd. All Rights Reserved.
The information in this document may contain predictive statements including, without limitation, statements
regarding the future financial and operating results, future product portfolio, new technology, etc. There are a
number of factors that could cause actual results and developments to differ materially from those expressed or
implied in the predictive statements. Therefore, such information is provided for reference purpose only and
constitutes neither an offer nor an acceptance. Huawei may change the information at any time without notice.

Das könnte Ihnen auch gefallen