Montabert Breaker

Charging Accumulators
& miscellaneous
Medium pressure accumulator
B700
PRESSURE REGULATOR
Ring
Plug High pressure accumulator
O ring
Spring Back head
Stop block Outlet
Shim
Assembling bolt
Spool Seals
Lining Inlet Distribution cover
Distributor
O ring
Distribution box
Piston
Centring pin
Cylinder
Cylinder Seals
Frequency adjustment

Elastic pin Nut


Spring Retaining pin
Lock
Front guide

Upper chuck bushing

Lower chuck bushing


B700

Medium Pressure
Accumulator

High Pressure
Accumulator
B700 High Pressure Accumulator

Remove the plug


Charge Pressure Gauge MEL 1523A
(with adapter)
B700
Slowly turn the gauge
valve body clockwise
until the gauge shows a
reading. If the pressure
is low, recharge the
breaker.

Correct Pressure B700,


B850, B950 is 500 PSI
To Charge

Install the
charging tool
with correct
adapter onto the
breaker.

Use the “Above


100 psi” side of
the tool.
Connect the
nitrogen hose to
the charging
tool.

Slowly open the


valve on the
nitrogen tank
and fill the
nitrogen
chamber to 500
PSI. Close the
valve on the
nitrogen tank.
Procedure is the same for the medium pressure accumulator.

Correct pressure is
B700 180 PSI
B850 190PSI
B950 220 PSI
Energy/Frequency Piston B700

STROKE DIFFERENCE

PILOTING PILOTING
LINE CLOSED LINE OPEN

P
I P
S I
T S
O T
N O
N

DISTRIBUTOR REVERSE MOVEM ENT IS GIVEN LATER DISTRIBUTOR REVERSE MOVEM ENT IS GIVEN EARLIER

LO NG ST ROKE En ergy Position SH ORT S TROK E H IG H FREQ UE NCY

Place in frequency position for model 453 loaders


B700

Remove the plug

Remove the piston

Shown in ENERGY position.


B700

Remove piston and install in cap to put in the


frequency position.

Shown in FREQUENCY position.


B700

To remove bit,
Use punch to push in the lock pin.
B700

Use punch to push the tool retainer down.


Remove the bit.
B700

Apply grease.

Last 8 inches.
B700

Align notch with the bit retaining pin hole.


Hydraulic Breaker Troubleshooting

WILL NOT FIRE


Machine Fluid Reservoir Low

No Hydraulic Flow To Breaker


Damaged Quick Couplers
Machine Main Relief Valve Set Too Low

Machine Hydraulic Pump Not Working

Breaker Nitrogen Chamber(s) Not At Correct Pressure


Breaker Nitrogen Chamber Diaphragm Damaged
Hydraulic Breaker Troubleshooting

RUNS SLOWLY OR SPEED REDUCING


Excessive Heat Build Up

Not Enough Hydraulic Flow


Damaged Quick Couplers
Machine Main Relief Valve Set Too Low

Excessive Back Pressure

Breaker Nitrogen Chamber(s) Over-Pressurized


Internal Breaker Leakage
Hydraulic Breaker Troubleshooting

Fires Erratically
Machine Fluid Reservoir Low

Damaged Quick Couplers

Machine Main Relief Valve Set Too Low

Excessive Back Pressure

Breaker Tool Binding


Hydraulic Breaker Troubleshooting

EXCESSIVE HEAT BUILD UP


Machine Fluid Reservoir Low

Blank Firing
Hydraulic Breaker Troubleshooting

POOR PERFORMANCE ON 453 LOADER


Energy/Frequency Piston Set In Energy Position