Beruflich Dokumente
Kultur Dokumente
Founded in 1993;
www.sandegroup.com
About Sundy
www.sandegroup.com
About Sundy
About Sundy
Sundy
www.sandegroup.com 12
Sundy all over the world
Sundy Activities
Sundy Activities
Sundy Customers
www.sandegroup.com
Sundy Customers
Sundy Customers
Sundy Customers
Sampling
Coal transportation way
Manual sampling way for coal
第
三
代
Quick drying
before pulverizing
<10 min
SDVD3mm Drying Device
SDUC3150 crushing-dividing
combined apparatus
SDPP Pulverizer
Sample Preparation Equipment
www.sandegroup.com
【 All pass sample preparation system 】
Automatic sample preparation for coal sample
Analysis
Calorimeters
SDAC6000 Automatic Bomb Calorimeter
• Conformance to Standards
• ASTM D 5865-2007 Standard Test Method for Gross Calorific Value of Coal and
Coke
• ISO 1928 Solid Mineral Fuels Determination of gross calorific value by the bomb
calorimetric method and calculation of net calorific value
Features
•Improved bomb design makes the operation easier while lifetime of Crucible support
consumables longer (O rings).
• Newly designed stirring method makes the stirring
efficiency much higher while less heat generation.
• Jacket and jacket lid with helix tube, plus chiller in jacket ,
makes it environment adaptability greatly improved.
15Min
Smart
chiller
4
samples
/hour
Smart Water Tank with Cooler
Built-in constant temperature water tank can process heating and cooling.
Jacket with Helix Tube
Oxygen Bomb and Power Inverter
With stainless steel oxygen bomb and unique stirring method by solenoid pump, heat transfer of oxygen bomb
and stirring efficiency is greatly improved.
Built-in power inverter can purify and stabilize power supply so that test result will not be affected by the fluctuation
of voltage and frequency.
Ethernet Communication
USB Can
Communication
50
120
100
Better Perfomance
◆ 50 samples
High
50 auto sample loader Efficiency
◆ 120 seconds
Total testing time Fast
◆ 100 times
Life of crucible
Economic
Better Perfomance
Hall Photoelectric
Position Position
Optimized Lower
Gas Circuit Chemical
Consumption
Specification
Launch at July
The performance of infrared cell is much improved. Time for constant temperature is
about 90min, which is much improved.
The crucible can be replaced from the top of instrument, which is easy to disassemble it.
SDCHN435
34 Auto
Loader
Automatic
Crucible
Replacing
www.sandegroup.com
SDCHN435
www.sandegroup.com
Specification
• Autoloader: 34 Samples
• Crucible Replacing: Automatic
• Sample Weight: 75~105mg
• Principle: CH: Infrared Absorption
N: Thermal Conduction
• Measuring range: C: 0.02%-100%
H:0.02%-50%
N:0.01%-50%
• Analysis Time: ≤ 5min/per sample
• Gas Requirement:
Combustion Supporting: Oxygen 99.5%
Driving Gas: Nitrogen 99.5%
Carrier Gas: Helium 99.99%
Proximate Analyzers (TGA)
SDTGA6000 Proximate Analyzer
Micro PC Controlled
Ash Fusibility Analyzer
SDAF105b
2019/7/4 www.sandegroup.com
Thank you!