MAIN FUNCTION OF ESP

 Generation of electric field high voltage DC.


 Generation of electric charges.

 Transfer of electric charge to dust particle.

 Movement of charged dust particle from electric


field to collecting electrode.
 Adhesion of charged dust particle to the surface of
collecting electrode.
 Removal of dust layer from the collecting electrode.

 Collection of dust in hopper.

 Removal of dust from the hopper.

1
Flue gas path
ESP-A
ID-A
APH-A

B ESP-B
O
Stac
I k
L
ESP-C
E
R APH-B ID-
B
ESP-D

ASH
AHP POND &
Silo 2
Ash Production & Handling

Fly ash (80%)


Boiler
The ash producer ESP Stack

Bottom ash (20%) Fly Ash Collection


99.97% Ash
pond
Bottom hoppers of (Wet

Boiler & Ash Ash)

Air pre heater handling


Economizer plant Silo (Fly
Ash)

3
LTMSB ( LT MAIN SWITCH BOARD)
 Feed power to
 1- Auxiliary control panels (ACP) (04 nos.)
 2-Electronic control panels (BAPCON PANEL) to
Field HVR Transformer (80 nos.)
 3- Rapper control panels (RAPCON PANEL)( 08
nos.)
 4- Status Control panels (STATCON PANEL) (04
nos.)
 5- Excitation system of VFD (02 nos.)
 6- AC ventilation MCC (02 nos.)
 7- Lighting Distribution Boards (02 nos.)
4
ACP ( AUXILIARY CONTROL PANEL ) =04

 Feed power to
 1- ESP Field support heaters (320 nos.)
 2- ESP Field shaft heaters (80 nos.)
 3- ESP hoppers heaters (160 set.)
 4- Opacity monitor of ESP pass & stack (05
nos.).
 5- CERM rapping motors (80 nos.).
 6-EERM rapping motors (80 nos.) .
 7-GDRM rapping motors (08 nos.).

5
A plant without an ESP