Sie sind auf Seite 1von 24

2 Subrack and board declaration

2.1
© Alcatel University - 8AS 90001 1860 VT ZZA Ed.03
2 Subrack and board declaration
Session presentation

 Objective: to be able to align and modify the MIB


according to the hardware configuration
 Program:
2.1 Local access request
2.2 Remote inventory display
2.3 Object administrative state modification
2.4 Object declaration
2.5 MIB management

2.2
2 Subrack and board declaration

2.1 Local access request

2.3
© Alcatel University - 8AS 90001 1860 VT ZZA Ed.03
2.1 Local access request

Craft access granted

Craft access denied

 To allow or to inhibit the craft access:


Supervision  Access State  OS
 Requested

2.4
2 Subrack and board declaration

2.2 Remote inventory display

2.5
© Alcatel University - 8AS 90001 1860 VT ZZA Ed.03
2.2 Remote inventory display
Board level

 To display the remote inventory data of


the selected board:
Equipment  Remote inventory
 Board Level

2.6
2.2 Remote inventory display
Global inventory storage

 To store the remote inventory data in the CT:


Supervision
 Upload Remote Inventory

2.7
2.2 Remote inventory display
Global inventory display

 To display the remote inventory data of


the NE previously stored in the CT:
Diagnosis
 View  Remote Inventory

2.8
2 Subrack and board declaration

2.3 Object administrative state modification

2.9
© Alcatel University - 8AS 90001 1860 VT ZZA Ed.03
2.3 Object administrative state modification
Administrative states

Out of Service

In Service

2.10
2.3 Object administrative state modification
State modification

1) Select an in Service or out


of Service object
2) Equipment
 Set out of Service
or
 Set in Service

2.11
2 Subrack and board declaration

2.4 Object declaration

2.12
© Alcatel University - 8AS 90001 1860 VT ZZA Ed.03
2.4 Object declaration
Declaration procedure

1) Select an empty (or out of


Service) slot (or subrack)
2) Equipment  Set
3) Choose the desired object

2.13
2.4 Object declaration
Modification procedure

1) Select an object (in


Service or out of Service)
2) Equipment  Modify
3) Choose the desired object

2.14
2.4 Object declaration
Deletion procedure

1) Select an out of Service


object
2) Equipment  Remove

2.15
2.4 Object declaration
Exercise

 Allow the CT access if necessary


 Display a board remote inventory
 Display the global inventory of your NE
 Make a hardware reset of the data base
in order to get the default configuration
of the NE (see Operator Handbook)
 Align the MIB according to the hardware
configuration

Time allowed:
45 minutes

2.16
2 Subrack and board declaration

2.5 MIB management

2.17
© Alcatel University - 8AS 90001 1860 VT ZZA Ed.03
2.5 MIB management
MIB definition

 The MIB describes all the managed


objects controlled by the system
 Any configuration modification will
immediately modify the MIB

MIB
Modification

2.18
2.5 MIB management
MIB backup

1) Download  MIB management


2) Enter a name for the backup
3) Click on Backup
4) Wait for the message « Backup
successfully completed! »

2.19
2.5 MIB management
MIB export
 This operation is only allowed if the NE management states are the following:
 Supervision: supervised
 For Local NE: connected plug

 In NES:
1) Supervision  Files Administration
 MIB Copies
 Save to disk
2) Open in sequence folders to show the file to be saved
3) Select it and click Open
4) Select the path where to save in the file and click Open
5) Wait for the message « The selected MIB has been copied to A:\ »

2.20
2.5 MIB management
MIB import
 This operation is only allowed if the NE management states are the following:
 Supervision: supervised
 For Local NE: connected plug

 In NES:
1) Supervision  Files Administration
 MIB Copies
 Load from disk
2) Select the path from which the configuration has to be copied
3) Search the file to be imported
4) Select it and click OK
5) Wait for the message « Package installed successfully »

2.21
2.5 MIB management
MIB restore

1) Download  MIB management


2) Select the backup to restore
3) Click on Restore
4) Wait for the message « Restore
completed! »
5) Click on Activate
6) Wait for the message « MIB
activation completed! »
7) Wait for the CPU restart

2.22
2.5 MIB management
Exercise

 Perform your own backup


 Export it to A:/
 Delete it in the 1320CT from the « NE
MIB management » window
 Remove (software) one board in the
« Equipment view »
 Import your backup from A:/
 Restore it
 Check that the board previously
removed is present
Time allowed:
35 minutes

2.23
2 Subrack and board declaration
Evaluation

 Objective: to be able to align and modify


the MIB according to the hardware
configuration

Thank you for answering


the self-assessment
of the objectives sheet

2.24