COAL
Is (from the Old English term col,
which has meant "mineral of fossilized
carbon" since the 13th century) is a
combustible black or brownish-black
sedimentary rock usually occurring in
rock strata in layers or veins
called coal beds or coal seams.
Is a readily combustible rock
containing more than 50 percent by
weight of carbonaceous material
formed from compaction and
indurations of variously altered plant
remains similar to those in peat.
ME 19-STEAM POWER ENGINEERING
TECHNNOLOGICAL UNIVERSITY OF THE PHILIPPINES
COAL FORMATIONS
ME 19-STEAM POWER ENGINEERING
TECHNNOLOGICAL UNIVERSITY OF THE PHILIPPINES
COAL CLASSIFICATION
ME 19-STEAM POWER ENGINEERING
TECHNNOLOGICAL UNIVERSITY OF THE PHILIPPINES
COAL CLASSIFICATION
PEAT
Peat (turf) is an accumulation of
partially decayed vegetation or organic
matter that is unique to natural areas
called peat lands, bogs, or mires.
ME 19-STEAM POWER ENGINEERING
TECHNNOLOGICAL UNIVERSITY OF THE PHILIPPINES
COAL CLASSIFICATION
LIGNITE
Often referred to as brown coal, is a soft
brown combustible sedimentary rock
formed from naturally compressed peat.
It is considered the lowest rank
of coal due to its relatively low heat
content.
It increases in maturity by becoming
darker and harder and is then classified
as sub-bituminous coal. After a
continuous process of burial and
alteration, chemical and physical
changes occur until the coal is classified
as bituminous - dark and hard coal.
ME 19-STEAM POWER ENGINEERING
TECHNNOLOGICAL UNIVERSITY OF THE PHILIPPINES
COAL CLASSIFICATION
BITUMINOUS
Also called black coal is a relatively soft
coal containing a tarlike substance called
bitumen.
It is of higher quality than lignite coal
but of poorer quality than anthracite.
Formation is usually the result of high
pressure being exerted on lignite.
It ignites easily and burns long with a
relatively long flame. If improperly fired
bituminous coal is characterized with
excess smoke and soot.
ME 19-STEAM POWER ENGINEERING
TECHNNOLOGICAL UNIVERSITY OF THE PHILIPPINES
COAL CLASSIFICATION
ANTHRACITE
It has the highest carbon content,
the fewest impurities, and the
highest calorific content of all types
of coal, which also include
bituminous coal and lignite.
Is a high-ranking coal with more
fixed carbon and less volatile matter
than bituminous, subbituminous,
or lignite varieties.
Is the last classification, the
ultimate maturation.
Is very hard and shiny.
ME 19-STEAM POWER ENGINEERING
TECHNNOLOGICAL UNIVERSITY OF THE PHILIPPINES
COAL ANALYSIS
PROXIMATE ANALYSIS-parameters include sulfur, moisture,
volatile matter, ash, and fixed carbon.
COAL ANALYSIS
PROXIMATE ANALYSIS-parameters include sulfur, moisture,
volatile matter, ash, and fixed carbon.
COAL ANALYSIS
PROXIMATE ANALYSIS-parameters include sulfur, moisture,
volatile matter, ash, and fixed carbon.
COAL ANALYSIS
PROXIMATE ANALYSIS-parameters include sulfur, moisture,
volatile matter, ash, and fixed carbon.
Measurement of moisture
The determination of moisture
content is carried out by placing a
sample of powdered raw coal of size
200-micron size in an uncovered
crucible, which is placed in the
oven kept at 108 ± 2 oC along with
the lid. Then the sample is cooled
to room temperature and weighed
again. The loss in weight represents
moisture.
ME 19-STEAM POWER ENGINEERING
TECHNNOLOGICAL UNIVERSITY OF THE PHILIPPINES
COAL ANALYSIS
PROXIMATE ANALYSIS-parameters include sulfur, moisture,
volatile matter, ash, and fixed carbon.
Measurement of volatile matter
COAL ANALYSIS
PROXIMATE ANALYSIS-parameters include sulfur, moisture,
volatile matter, ash, and fixed carbon.
Measurement of carbon and ash
The cover from the crucible used
in the last test is removed and the
crucible is heated over the Bunsen
burner until all the carbon is
burned. The residue is weighed,
which is the incombustible ash.
The difference in weight from the
previous weighing is the fixed
carbon. In actual practice Fixed
Carbon or FC derived by
subtracting from 100 the value of
moisture, volatile matter and ash.
ME 19-STEAM POWER ENGINEERING
TECHNNOLOGICAL UNIVERSITY OF THE PHILIPPINES
COAL ANALYSIS
PROXIMATE ANALYSIS-parameters include sulfur, moisture,
volatile matter, ash, and fixed carbon.
Typical Sulfur Content in Coal Typical Moisture Content in Coal
Anthracite Coal : 0.6 - 0.77 weight % Anthracite Coal : 2.8 - 16.3 weight %
Bituminous Coal : 0.7 - 4.0 weight % Bituminous Coal : 2.2 - 15.9 weight %
Lignite Coal : 0.4 weight % Lignite Coal : 39 weight %
Typical Fixed Carbon Content in Typical Density of Coal
Coal 1100 - 1800 (kg/m3)
Anthracite Coal : 80.5 - 85.7 weight %
Bituminous Coal : 44.9-78.2 weight %
Lignite Coal : 31.4 weight %
Typical Bulk Density of Coal
Anthracite Coal : 50 - 58 (lb/ft3), 800 - 929 (kg/m3)
Typical Ash Content in Coal
Bituminous Coal : 42 - 57 (lb/ft3), 673 - 913 (kg/m3) Anthracite Coal : 9.7 - 20.2 weight %
Lignite Coal : 40 - 54 (lb/ft3), 641 - 865 (kg/m3) Bituminous Coal : 3.3-11.7 weight %
Lignite Coal : 4.2 weight %
ME 19-STEAM POWER ENGINEERING
TECHNNOLOGICAL UNIVERSITY OF THE PHILIPPINES
COAL ANALYSIS
ULTIMATE ANALYSIS-indicates the various elemental
chemical constituents such as carbon, hydrogen, oxygen,
nitrogen, sulfur, ash, and moisture. It is useful in
determining the quantity of air required for combustion
and the volume and composition of the combustion
gases. This information is required for the calculation of
flame temperature and the flue duct design etc.
ME 19-STEAM POWER ENGINEERING
TECHNNOLOGICAL UNIVERSITY OF THE PHILIPPINES
COAL ANALYSIS
ULTIMATE ANALYSIS
Carbon Content
By far the major component of coal, is the principal source of heat, generating about
14,500 British thermal units (Btu) per pound. The typical carbon content for coal (dry
basis) ranges from more than 60 percent for lignite to more than 80 percent for anthracite.
Hydrogen Content
It generates about 62,000 Btu per pound, it accounts for only 5 percent or less of coal and
not all of this is available for heat because part of the hydrogen combines with oxygen to
form water vapor.
Oxygen Content
The higher the oxygen content of coal, the lower its heating value. This inverse relationship
occurs because oxygen in the coal is bound to the carbon and has, therefore, already
partially oxidized the carbon, decreasing its ability to generate heat.
ME 19-STEAM POWER ENGINEERING
TECHNNOLOGICAL UNIVERSITY OF THE PHILIPPINES
COAL ANALYSIS
ULTIMATE ANALYSIS
Nitrogen Content
Has no calorific value and hence ist presence in coal is undesirable, Thus a good quality
coal should have a very little Nitrogen content.
Sulfur Content
The amount of heat contributed by the combustion of sulfur in coal is relatively small,
because the heating value of sulfur is only about 4,000 Btu per pound, and the sulfur
content of coal generally averages 1 to 2 percent by weight.
ME 19-STEAM POWER ENGINEERING
TECHNNOLOGICAL UNIVERSITY OF THE PHILIPPINES
COAL ANALYSIS
ULTIMATE ANALYSIS
Basis of Reporting Analysis
As received or as Fired
Dry or Moisture Free
Moisture and Ash Free or Combustible
Moisture, Ash, and Sulfur Free
ME 19-STEAM POWER ENGINEERING
TECHNNOLOGICAL UNIVERSITY OF THE PHILIPPINES
Sample Problems
Report the analysis of following fuel using the following basis:
As fired/as received
Moisture free/dry
Moisture and Ash Free/Combustible
Moisture, Ash, and Sulfur free
Heatin
g Vale
Proximate Ultimate
County
Rank
State
Hydrogen
Moisture
Nitrogen
Oxygen
Carbon
Carbon
Volatile
Matter
Sulfur
Fixed
Ash
Cherokee
Kansas
13,082
34.47
52.17
71.81
10.15
5.09
8.27
3.34
5.23
1.20
Bit
Carbon
12,521
39.72
47.17
69.12
17.18
Utah
7.49
5.62
0.64
6.09
1.35
Bit
ME 19-STEAM POWER ENGINEERING
TECHNNOLOGICAL UNIVERSITY OF THE PHILIPPINES
COAL ANALYSIS
HIGHER HEATING VALUE
The higher heating value (also known gross calorific value or
gross energy) of a fuel is defined as the amount of heat released
by a specified quantity (initially at 25°C) once it is combusted
and the products have returned to a temperature of 25°C,
which takes into account the latent heat of vaporization of
water in the combustion products.
ME 19-STEAM POWER ENGINEERING
TECHNNOLOGICAL UNIVERSITY OF THE PHILIPPINES
Sample Problems
Calculate the boiler heat balance on the as fired basis for the following
data
Fuel: Cherokee County, Kansas Coal
Gas Analysis: 14.2% CO2 , 0.3% CO, 4.3% O2
Coal fired: 22,260 lb/hr
Refuse: 2,560 lb/hr
Water: 202,030 lb/hr
Water entering: 324.7oF
Steam leaving: 476 psig, 743oF
Fuel and room temperature: 82oF
Gas temperature: 463oF
ME 19-STEAM POWER ENGINEERING
TECHNNOLOGICAL UNIVERSITY OF THE PHILIPPINES
COAL ANALYSIS
THEORETICAL AIR REQUIRED
COAL ANALYSIS
WEIGHT OF REFUSE
COAL ANALYSIS
WEIGHT OF DRY GAS
COAL ANALYSIS
ACTUAL WEIGHT OF AIR
ME 19-STEAM POWER ENGINEERING
TECHNNOLOGICAL UNIVERSITY OF THE PHILIPPINES
END OF PRESENTATION