du LTE Project Network Topology

Page 3
Performing the E NodeB Power-On Check

After all devices are installed, you need to check the power-on status of the BBU and RRU.
Figure 1 BBU power-on check process
Checking the Power-On Status of the RRU
BBU3900 Slot Allocation

Before we proceed with the software commissioning please make sure the
Hardware are inserted as per the design and make sure the board types are
as mentioned in design.
Local Commissioning Modes

•Local commissioning on the LMT

•Local commissioning using a Universal Serial Bus (USB)


flash drive

Note: Please ensure to download and activate the Digital certificates before
Proceeding with Commissioning.
LMT Commissioning Procedure- Digital Certificates
Preparation

1.Obtaining Digital Certificates

Description: Before commissioning an eNodeB, obtain the operator's root


certificate. The operator's root certificate is used for the eNodeB to authenticate
the SeGW when establishing IPSec tunnels.

Certificate Files Name to be prepared:

“Huawei RadioSubCA.crt” & “CentralElementSubCA(20111206).p7b”

(For Certificate files, please go to FAQ#3)


LMT Commissioning Procedure- Digital Certificates
Preparation
2.Downloading the Digital Certificate on the LMT

Procedure
Download the operator's root CA certificate to the eNodeB by running the DLD
CERTFILE command.

DLD CERTFILE:IP="192.168.0.50",USR="admin",PWD="*****",SRCF="Huawei
RadioSubCA.crt",DSTF="Huawei RadioSubCA.cer",CT=TRUSTCERT;
LMT Commissioning Procedure- Digital Certificates
Preparation
2.Downloading the Digital Certificate on the LMT

Procedure
Download the operator's root CA certificate to the eNodeB by running the DLD
CERTFILE command.

DLD
CERTFILE:IP="192.168.0.50",USR="admin",PWD="*****",SRCF="CentralElementSu
bCA(20111206).p7b",DSTF="CentralElementSubCA(20111206).p7b",CT=TRUSTCE
RT;
LMT Commissioning Procedure- Digital Certificates
Preparation
2.Downloading the Digital Certificate on the LMT

Procedure
Add the operator's root CA certificate by running the ADD TRUSTCERT.
ADD TRUSTCERT:CERTNAME="Huawei RadioSubCA.cer";
LMT Commissioning Procedure- Digital Certificates
Preparation
2.Downloading the Digital Certificate on the LMT

Procedure
Add the operator's root CA certificate by running the ADD TRUSTCERT.
ADD TRUSTCERT:CERTNAME="CentralElementSubCA(20111206).p7b “;
LMT Commissioning Procedure---System
Requirements
LMT Commissioning Procedure- Connecting PC to Main
UMPT Board

Ethernet cable LMPT: The Ethernet cable directly connects the laptop to the
eNodeB.

UMPT: The Ethernet cable connects the laptop to the USB-to-


Ethernet port transfer cable.
Local maintenance The LMA connects the USB port on the UMPT to the Ethernet cable.
adapter (LMA)
LMT Commissioning Procedure---Login
Enter the IP address of the LMPT for local maintenance in the address box of the Internet
Explorer (the default IP address is 192.168.0.49).
The Local Maintenance Terminal login dialog box is displayed, as shown in Figure.
LMT Commissioning
Procedure---Login
LMT Username and password:

By default, the user name and password are admin and


admin123, respectively.

For eNodeB from factory need to use the New password


mentioned for local login

Fill in the User Name, Password, and Verify Code boxes. Set User Type to
Local.
LMT Commissioning Procedure---FTP Server Setup
Configuring the FTP Server Context:
Because the eNodeB software, data configuration file, and license are downloaded
from the FTP
server to the LMT, ensure that the FTP server has been configured before the
download.
LMT Commissioning Procedure---FTP Server
Setup
Procedure for FTP setup

Step 1 From the LMT main menu, click the Software Management tab. The Software
Management tab page is displayed.
Step 2 In the navigation tree, double-click FTPServer Configuration. The FTPServer
Configuration pane is displayed, as shown

3. Click Download FTP Tool. The File Download-Security Warning dialog


box is
displayed.
4. Click Save to save the FTP server software package (SFTPServer.exe)
to the LMT PC.
LMT Commissioning Procedure---FTP Server Setup
Procedure for FTP setup (Continue….)

3. Set User name, Password, and Working directory for the FTP server. The default user
name and password are admin. Working directory must be set to the directory where the
software and data configuration file are saved. The default transmission security mode isBoth.
4. Click OK.
LMT Commissioning Procedure---FTP Server Setup
Procedure for FTP setup (Continue….)

Step 5 Save the FTP server configuration on the LMT main window.

1.On the LMT, click Software Management. The Software Management tab page is
displayed.

2. On the FTP Server Configure tab page, set IP address for the FTP server.

3. Enter User name and Password based on the settings in Step 4.3. The default name
and password are admin.

4. Click Save to save the FTP server configuration.


----End
LMT Commissioning Procedure---Software
Management
Downloading and Activating the eNodeB Software and Data
Configuration File on the LMT
Prerequisites
The LMT communicates properly with the eNodeB.
The FTP server is connected to the eNodeB in the same network segment and is functioning
properly.
There is no firewall between the FTP server and the eNodeB.
Hardware installed in required Slots as per design
Digital certificated are installed and activated

Procedure
1. In the MML window on the LMT, run the LST VER command to query the active eNodeB
software version.
LMT Commissioning Procedure---Script and License
Downloading
Download and activate the eNodeB software and data configuration file
using the GUI or MML commands.
Using GUI
a.On the LMT, click Software Management. The Software Management dialog box is displayed.
b.In the navigation tree, double-click Download and Activate Software. The Download and Activate
Software window is displayed,

C. Select tasks to be performed accordingly and set the parameters related to the tasks.
Local Commissioning Using a USB Flash Drive

Commissioning Procedure
This section describes how to perform local eNodeB commissioning using a Universal Serial Bus
(USB)

Prerequisites
* The eNodeB software package and data configuration file are available.
*The commissioning license is ready if you need to load and activate the license file using the USB
flash drive.
•The USB flash drive and commissioning files have been scanned by using the antivirus software and
no virus was detected. The commissioning files include the software package,data configuration file,
and license file.
USB flash drive
* The USB flash drive is equipped with an indicator that indicates the data transmission status.
* Capacity ≥ 256 MB
*The USB flash drive must not provide any additional functions,such as encryption, virus scanning,
and bootstrapping. In addition, it cannot be an MP3 player, MP4 player, or smartphone.
*The USB flash drive used for commissioning cannot be used for other purposes
USB Commissioning Procedure
Pre check Points
1. Obtain the eNodeB software and files for automatic eNodeB deployment.
NOTE
* The eNodeB software package is ready, and can be downloaded from Huawei Engineer.
The default configuration file (Precfg.ini) is provided in the software package.
*The name of the data configuration file must be CFGDATA.XML. The file name is case-sensitive.

2. Save the required files to the following paths of the USB flash drive, depending on the specific
scenarios, shown in Table 2 (The save path is case-sensitive and cannot be changed.)
USB Commissioning Procedure-
Step 1 Check whether the eNodeB is powered on. If it is not powered on, power on the
eNodeB. If it
is already powered on, go to Step 2.
NOTE
Ensure that the RRU is powered on and the common public radio interface (CPRI) connections
are correct
before you power on the eNodeB. Check for faults by monitoring the CPRI indicator status on
the LBBP
after the eNodeB is powered on. For details, see Checking the Status of Indicators.
Step 2 When the eNodeB operates properly, insert the USB flash drive into the USB port
on the
BBU3900 main control board. If an LMPT is used, the USB port is shown in Figure 3-15; if an
UMPT is used, the USB port is shown in Figure
USB Commissioning Procedure

Step 3 Wait for the eNodeB to automatically upgrade the software and data configuration file.
If the download or activation fails, commission the eNodeB by updating the software and data
configuration file in the USB flash drive or using a new USB flash drive.
If the download or activation still fails, perform the local eNodeB commissioning on the LMT.
When the software and data configuration file are being upgraded, the normal status of the
indicators on the USB flash drive and main control board is shown .
Integration Verification
Integration Verification

Checking the Status of Indicators

Indicator status of the functional eNodeB


Integration Verification
1. Check the Transmission Reachability
LST DEVIP

LST IPRT

Page29
Integration Verification
Ping test till the router gateway to verify the reachabillty till routers
Integration Verification

2.Software verification

Check the current version using LST VER command in


LMT MML

All eNodeB should be in V100R005C00SPC340 version


Integration Verification

3. Query the status of the IKE Security Association (SA).

DSP IKESA
Integration Verification
Checking the Operating Status of the eNodeB on the LMT

Procedure
1.On the LMT, click Self-Test. On the displayed Self-Test tab page, a man-machine language (MML) command
script with the complete parameter settings is automatically imported to the command area.
2.Click Execute. The execution result is displayed in the area below Execute.

NOTE:
If all items pass the check, the eNodeB operates properly. Otherwise, check for active alarms and clear them. If
all active alarms are cleared but the fault persists, contact Huawei for technical support.
FAQs
1. How to check physical link status is up?

o Check Optical model type @ eNB and RTN sides.


BOM#34060473 eSFP-1310nm-1000Base-Lx SM Optical
transceiver,eSFP,1310nm,1.25Gb/s,-9~-3dBm,-20dBm,LC,Single
Mode,10km

o Check Configuration of the Port, speed and duplex mode


Speed =1000MDuplex = Full Duplex

o Run LST ETHPORT and DSP ETHPORT on LMT.

To check the port status “Port Status = Up”


DSP ETHPORT:SN=6,SBT=BASE_BOARD;

To check the port Attribute should be “Fiber” or “Copper” based the real
connection.

Page34
FAQs
2. What’s the issue Macro site 2*2 MIMO cell setup failure?

For Macro site, due to low speed of SFP module, 2*2 MIMO cells are
failed to setup.
o Check Optical model type @ eNB and RRU sides.
BOM#34060365 MultiMode SFP required

o Run “DSP CPRILBR”


Cabinet No. Subrack No. Slot No. Node Max bit rate(Gbit/s)

0 0 3 Head 2.5
0 60 0 0 2.5
(Number of results = 2

o Replace the SFPs based on above display results

Notes: For IBS sites, SFP is required 1.25Gbit/s to setup SISO cell.

Page35
FAQs
3. What kindly of files need to be well-prepared to integrate one new LTE site?

Before go to any site to check the followings.

o NodeB Script file named as “NodeBCFG.xml” (It will be sent through email)

o Commissioning license file “Demo_LTE_V100R005_ALL_20120717.dat”

o Digital Certificates files” Huawei RadioSubCA.crt “ and


“CentralElementSubCA(20111206).p7b”

o IP Plan Database in LLD file “du LTE Expansion Project Low Level Design
V3.0-Wireless (18th,Oct).xlsx”

Page36