DUG commissioning

Step by step

Prepared by Ammar Babiker


Connection Cable
The Same cable for RBS 2000 cabinets, But we add to it a
new (Serial  RJ cable) with the following pin
assignment.

Prepared by Ammar Babiker


Prepared by Ammar Babiker
Connecting the OMT
• Connect the cable to LMT A of the DUG

Prepared by Ammar Babiker


Serial board
Which communication board used by PC?

Prepared by Ammar Babiker


OMT
You need to configure new site as below
configuration:
4/4/4/0/0/0.

Prepared by Ammar Babiker


OMT
You must choose same serial port in Pc & OMT
• Start the OMT.
• In the Tools menu , click
Optuons (This opens up the
Options window).
• Select same port as in Pc..

Prepared by Ammar Babiker


Create IDB
Step 1:
• From configuration menu choose create IDB
or click in this icon

Step 2:
• From Create IDB window choose New or Modify

Prepared by Ammar Babiker


Cabinet Setup
Define Setup for Cabinet:
• Cabinet Type:
– RBS Series and version (RBS 2000 , RBS 6000 ,……etc.).

• Power System:
– RBS connected direct to AC
– RBS connected to Cabinet power

• Climate System:
– Number of fan groups.

Prepared by Ammar Babiker


Creating IDB
-Start the OMT.
In the Configuration menu , click Create IDB (This opens up the Create
IDB window).

Prepared by Ammar Babiker


Antenna Sector Setup
• Number of sector:
• Frequency
• Antenna sharing
• RUS
• TMA
• RE Setup

Prepared by Ammar Babiker


Radio Equipment Setup
• Radio Mode
– Single.
– Mixed ( can handle tow technologies together out of three 2G, 3G
and 4G)

• Number of TRX/MCTR
– Depend on site configuration per sector

Prepared by Ammar Babiker


Antenna Sector Setup
 Click Ok in the Define
Antenna System window
to confirm.
 If addtitional antenna
systems will be defined in
the sector, then repeat the
steps above.
 Select RE Setup(to select
number fo TRX/MCTR as
site requierment)

Prepared by Ammar Babiker


Antenna Sector Setup
 RE Type
 Radio Mode
 Number fo TRX/MCTR

Prepared by Ammar Babiker


Create IDB Window

 In the Final
Configuration
Selection window,
select the site cell
configuration (SCC).
 Verify that correct
parameters have
been entered. Click
Ok.

Prepared by Ammar Babiker


Final Configuration Selection window
 From Final Configuration
Selection window select OK.
 If choose Configuration Wizard,
select Run Configuration Wizard
but here we don’t need to use
Wizard configuration.

Prepared by Ammar Babiker


In Final Configuration Selection window
we shown a message as below screen shot select NO.

Prepared by Ammar Babiker


In Final Configuration Selection window
we shown a message as below screen shot select YES.

Prepared by Ammar Babiker


OMT

Prepared by Ammar Babiker


Defining Present RU
There are two ways to define Present Rus :
 Click the Configuration Menu then select Define and select
Present Rus.

 click the shortcut button/toolbar as shown

Prepared by Ammar Babiker


Shown below screen shot to Defining
Present RU

Prepared by Ammar Babiker


Defining Present RU

 Move the RUs in the configuration


used to Present box by selecting the
RU to be moved and clicking ← key
(or double-clicking the RUs to be
moved).
 Click Ok when finished.

Prepared by Ammar Babiker


Define RU position
from Configuration Menu select Define then RU Position
as below screen shot

Prepared by Ammar Babiker


Screen shot describe RU position

Prepared by Ammar Babiker


Define RU Position
from Define RU Position window select Shelf & Slot

Prepared by Ammar Babiker


Define RU position

Prepared by Ammar Babiker


Define RU position

After Define RU position:


 Installed Cabinet must
be similar to the
cabinet that created by
OMT( To help field
maintenance to find
alarm easily)

Prepared by Ammar Babiker


Define HW information
(if this cabinet is master)

Prepared by Ammar Babiker


Define RBS 6000 HW information
as below screen shot

Prepared by Ammar Babiker


Defining Alarm Inlets (External Alarms)

Prepared by Ammar Babiker


In Defining Alarm Inlets window
-Select SCU (if we connected External Alarms dirctly to SCU).
-Select SAU (if we connected External Alarms dirctly to SAU).

Prepared by Ammar Babiker


In Defining Alarm Inlets window
In the Inlet Usage box, select ”External Alarm”.

Prepared by Ammar Babiker


 In the Type box, define the
Defining Alarm Inlets alarm type as ”Closing (when
there is an alarm, the alarm
cable closes) or ”Breaking”
(when there is an

Prepared by Ammar Babiker


Defining Alarm Inlets  Add a comment in the
Comment box, if
required.

Prepared by Ammar Babiker


Prepared by Ammar Babiker
Prepared by Ammar Babiker