Case Study

Introduction
• Location- New Delhi
• Geographical coordinates
- 28° N, 77° E
• Occupancy Type- Office
(MoEF)
• Typology- New
Construction
• Climate Type- Composite
• Project Area- 9565 sqm
• Wider Front Setback (22m) to
protect front tree line .

Emphasis on the North & South for Optimal


Solar Light but cutting Solar Heat, Bringing the
Greens in
Ground Floor Plan
Indira Paryavaran Bhawan uses 70% less energy compared a
conventional building.

• The Courtyard also helps in


air movement besides
being a shaded interaction
space_x0000_

Provision of Solar
Photovoltaics for Net Zero
requirement also Shades the
Roof.
Elevation

• Photovoltaics Stepping towards the south side creating a strong


agenda for the future for urban buildings on limited site areas.
Utilizing lessons from nature &
traditional buildings
-Maximum Ground Coverage Used (30%) to keep building height comparable to
the surroundings
- Respecting the Eco-
logic of the site.
Building Punctures &
jalis to Aid Cross
Ventilation and
maximizing non –
conditioned spaces like
lobbies, passages,
service areas
Energy conservation measures
Annual energy
production and
consumption
(kwh)

Energy
consumption on
site
Geothermal Cooling
Condenser water heat shall be rejected
to earth by boring at suitable depth &
sending hot water at 100°F (37.8° C)
& back at 900 F (32.2° C).
• Enormous water saving since no make
up water is required.
• Make up water pumping & treatment
cost get eliminated.
• Saves cooling tower fan energy.
Lighting design

• Energy efficient lighting system ( LPD = 5 W/m2) , nearly 50%


more efficient than Energy Conservation Building Code 2007
requirements ( LPD = 11 W/m2) reduces energy demand
further.
• Remaining lighting load supplied by building integrated
photovoltaic (BIPV).
• Use of energy efficient lighting fixtures (T5 lamps).
• Use of lux level sensor to optimize operation of artificial lighting.
Active Chilled Beams

• Working Principle
• Supply air flows through
nozzles in small air jets which
induce room air to flow
around the coil & air gets
cooled.
• Design / Constructional /
operational advantages

• Reduces power consumption


• Reduces power
consumption
• Easy Installation
• No noise as no
moving parts
• Easy Air balancing
activity

• No filters
maintenance
• Save architectural
space height
_x0000_
Net Zero Design
• N-S Orientation– Extensive Greenery to reduce heat load
• Maximizing Day lighting to reduce lighting loads
• Extremely Low Lighting Power Density – 5w/sqm
• Planning to Minimize AC loads (Keeping open atrium for cross ventilation, Non
conditioned lobbies).
• Ground based heat exchange for Condenser Water .
• Energy efficient appliances (5 star BEE).