Sie sind auf Seite 1von 11

Spirax Sarco Orifice Plate System

17 November, 2019 1 www.coulton.com


How they work....

Flow

dp

17 November, 2019 2 www.coulton.com


Orifice calculations...

The pressure drop across an orifice plate is


used to derive the rate of flow
using.......................

 BS 1042
 ISO 5167
 ASME MFC - 3M (1989)

Flow = K dP

17 November, 2019 3 www.coulton.com


Orifice Plate Output

100 Flow Error 1:1


90
80
70
60
%DP

50
40
30
20
Flow Error 2:1
10
0
0 20 40 60 80 100 120
% Flow

17 November, 2019 4 www.coulton.com


Traditional M240G system

17 November, 2019 5 www.coulton.com


Pressure transmitters FCX-A/CII

Dual Temperature Compensation

Eprom
Silicon Sensor

17 November, 2019 6 www.coulton.com


Pressure transmitters FCX-A/CII
 Both Types use
Measuring cell with floating sensor

– Floating silicone sensor in the cell neck,


to improove the static pressure, overload
and temperature characteristics.

– Protection diaphragm in the cell body


allows an overload pressure
corresponding to the maximum static
pressure without damage of the sensor.

17 November, 2019 7 www.coulton.com


Pressure transmitters FCX-A/CII

 Capacitance silicone sensor

– The micro machined silicone sensor is


based on the capacitance measuring
principle. Capacitance C1 & C2 change
with applied differential pressure.

– Cell protected from temperature variation


by silicon fabrication and minimmal
physical size.

– Stress forces are balanced by floating cell


design.

17 November, 2019 8 www.coulton.com


Pressure transmitters FCX-A/CII

 Matching Convolutions reduce volume

Convolutions are machined on the body.

Diaphragm is electron beam welded to the body

Diaphragm is pressed to body.

 Benefits
 No damage on over pressure
 Improved Temperature Spec
 Reduced Stress

17 November, 2019 9 www.coulton.com


17 November, 2019 10 www.coulton.com
ORIFICE PLATE FLOWMETERS
Advantages:
 Low cost, especially on large sizes
 No need for recalibration
 Widely accepted
Disadvantages:
 Poor turndown (4:1 typical)
 Long installations
 Subject to wear.

17 November, 2019 11 www.coulton.com