Foundation
Foundation
Soil
Limitations
• Applicable only foe residential buildings
• Minimum Two bays needed in any direction
• Foundation applicable for isolated building
only
• All Columns resisting lateral load shall be
vertical and shall continue on the same
centerline down to foundation level.
• No soft storey on a building.
Layout Limitations
• A or B < 6bays
• Maximum length = 25m
• One bay < 4.5m
• A<3B and B/3
• A*B <13.5 Sq.m
• H/A or H/B <3
• H< 11m or 3 stories
Limitations : Layout
• Wings of the structure
- K1 and K2 < A/4 or B/4
- Width of wing > K1/2 or K2/2
Basis of Recommendations
• Building : Residential
• Column Plan : 4.5 * 3.0 m bays
• Number of Storey : 3
• Storey Height :
1st Storey = 3.2m
Upper Storey = 2.8m
• Wall thickness : All internal wall = 115mm
Infill and Outer wall= 230to 240 mm
• Cantilever projection : 1.0 m from centre line of the beam
Basis of Recommendations
• Concrete Mix : M20 (20 N/mm2)
• Rebar : Fe 250, Fe 415, Fe 500
• Mortar : one brick thick wall – 1:6 cement- sand
half brick thick wall – 1:4 cement- sand
• Bricks : Minimum Crushing Strength of 3.5 N/mm2
• Seismic Coefficient : Cd = 0.09 *1.0 + 0.09
Design of Frames
• All Frames shall be designed:
a. To support the applied vertical gravity
loads ( including the weight of infill walls)
without assistance from the infill walls
b. For seismic conditions, using a seismic
coefficient equal to Cd.
Toe Wall and Plinth Beam
• All plinth beams shall be constructed on the
toe walls
• Depth of toe wall below ground level – 450
mm or 1.5 ft ar as required.
• Height of plinth = 450 mm or as required.
Wall Outside
Frame
Parapet
Wall
Bands
Proper Building Ground Floor Plans