Beruflich Dokumente
Kultur Dokumente
CONFERENCE CENTER
The Crystal is open to the public
and city decision makers, EXHIBITION
incorporating a conference
center with 270 seat auditorium
as well as office spaces
Auditorium 50 seats
100 officedesks
with 270seats cafeteria
•HVAC WEATHER
LIGHTING
STATION
GROUND SOLAR
SOURCE HEAT THERMAL BLACKWATER
PUMP WATERSYSTEM
35 34
LEED points
WATER SELF
30
25
26
90% SUFFICIENCY
86/109 20
14 15
15 30
points IMPROVED ENERGY
AvailablePoints
10
5
23
10
10 9
6
5
4
4
42% EFFICIENCY
Targeted Points 3
0
Sustainable Water Energy & Materials& Indoor Innovation Regional
Sites Efficiency Atmosphere Resources Environmental in Design Priority
Quality
35
BREEAM points
30 27
OUTSTANDING 25
20
18 16
14 15
15 12
86.92% 10
25
8 8 10
16 13
AvailablePoints 5 13
8 8 8 9 7
Targeted Points
0
Management Healthand Energy Transport W ater Materials W aste Land Use Pollution
well being andEcology
I
N
T
E
R
N
E
T
O
F
T
H
I
N
G
S
DESIGO BUILDING
AUTOMATION SYSTEM
BMS
ENERGY SYSTEMS
100% electric building, ENERGY RECOVERY SYSTEM
20% generated by PV panels
80% from UK power networks
84 power meters separately for power and lighting
BUILDING ENVELOPE
BUILDING ENVELOPE
ELECTRICITY SYSTEMS
HEATING AND COOLING
WATER SYSTEMS
TRANSPORT
Building Management System
BMS
DOMESTIC
CHILLER PLANTS SOFTENER PUMP
PUMPS FIRE ALARMS BASEMENT 1
TCP/IP CONTROLLERS
HEATING AND COOLING
KEY POINTS
HVAC EQUIPMENTS
EQUIPMENT QTY.
CHILLER PLANT 10
COOLING TOWER 11
CT FANS 14
CONDENSOR PUMP 14
SECONDARY PUMP 14
VFD 10
PRIMARY PUMP 12
MAIN CHILLER PUMPS HVAC DUCTS AND PIPELINES
Cctv surveillance AND FIRE ALARM SYSTEM
PA SYSTEM
CCTV and PA BASEMENT 1
system
KEY POINTS
• Fire alarms are grouped into
KEY POINTS sections and information from
• CCTV surveillance and PA system managed all sensors is relayed to fire-
through one computer system located in boxes located in basement 1.
basement 1 • At the time of study, fire
• All the hardware and management systems alarms were dysfunctional
for CCTVs are provided by PELCO managed due to maintenance work.
by Schneider Electric. • Smoke Detectors coupled
• Use of Internet Protocol (IP) cameras allows with sprinkler systems are
for remote supervision. used, however the exact type
• Surveillance system is not integrated with of equipment is unknown. Fire alarms for different sections of the mall
the main BMS. CCTV hub
List of equipments
PLUMBING EQUIPMENTS STP EQUIPMENTS
EQUIPMENT QTY EQUIPMENT QTY
RO 2 FAB FEED PUMP 4
UV 1 WATER FEED PUMP 2
DOMESTIC PUMP 6 SOFTENER PUMP 2
SOFT WATER TRANSFER PUMP 6 SLUDGE TRANSFER PUMP 2
HYDROPNUMATIC PUMP 9 SLUDGE SCREW PUMP 1
SUMP PUMPS 10
Surveillance and recording PA system hub controlling various speakers
SEWAGE PUMPS 5