Beruflich Dokumente
Kultur Dokumente
com
Scope of Work
Site Solution
Additional Work
Implementation Flow and Checklist
Solution Quantity
Grand Total 30
BTS3900A BTS3900A
Remove WMPT and GTMU then add UMPT at slot 7 (from H3I WH)
TCU TCU Add 1 pcs UBBPe4 at slot 2
SLPU SLPU Replace existing UPUE with 1 pcs UPEUd
Replace existing FANa with FANc
PMU PSU PSU PSU PMU PSU PSU PSU
Move 1 pcs WBBP from slot 2 to available slot (if any)
PDU PDU Replace 3 pcs existing CPRI 2G RFU with new one
Install Dummy BBU Cover 1 pcs
WBBP WBBP WBBP
Replace 1/2/3 pcs DRFU to MRFU (if any)
WBBP
FANc
WBBP
FAN
GTMU
UPEUd
UBBPe4
UPEU
WBBP
WBBP WMPT WBBP UMPT
DCDU DCDU
FMU FMU
GL1800 MRFU
GL1800 MRFU
GL1800 MRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
BTS3900A BTS3900A
Remove WMPT and GTMU then add UMPT at slot 7 (from H3I WH)
TCU TCU Add 1 pcs UBBPe4 at slot 2
SLPU SLPU Replace existing UPUE with 1 pcs UPEUd
Move 1 pcs WBBP from slot 2 to available slot (if any)
PMU PSU PSU PSU PMU PSU PSU PSU
Replace 3 pcs existing CPRI 2G RFU with new one
PDU PDU Install Dummy BBU Cover 1 pcs
Replace 1/2/3 pcs DRFU to MRFU (if any)
WBBP WBBP WBBP
WBBP
FANc
WBBP
FANc
GTMU
UPEUd
UBBPe4
UPEU
WBBP
WBBP WMPT WBBP UMPT
DCDU DCDU
FMU FMU
GL1800 MRFU
GL1800 MRFU
GL1800 MRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
G1800 GRFU
G1800 GRFU
G1800 GRFU
TCU TCU
SLPU SLPU
PMU PSU PSU PSU PMU PSU PSU PSU
PDU PDU
WBBP WBBP WBBP
WBBP
FANc
WBBP
FANc
GTMU
UPEUc
UPEUd
WBBP UBBPe4
WBBP WMPT WBBP UMPT
Remove WMPT and GTMU then add UMPT at slot 7 (from H3I
WH)
Move 1 pcs WBBP from slot 2 to available slot (if any)
Add 1 pcs UBBPe4 at slot 2
Replace existing UPUE with 1 pcs UPEUd
Replace SFP connector of 2G RRU on UBBP and on RRU 6 pcs
Install Dummy BBU Cover 1 pcs
BOTTOM OF RACK BOTTOM OF RACK
TCU TCU
SLPU SLPU
PMU PSU PSU PSU PMU PSU PSU PSU
PDU PDU
WBBP WBBP WBBP
WBBP
FAN
WBBP
FANc
GTMU
Install 3 new RRU2T2R 1800
UPEU
WBBP
UPEUd
UBBPe4
WBBP WMPT Dismantle 3 pcs existing 2G RFU WBBP UMPT
Remove WMPT and GTMU then add add UMPT at slot 7 (from H3I WH)
Add 1 pcs UBBPe4 at slot 2
Replace existing UPUE with 1 pcs UPEUd
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
Replace existing FANa with FANc
RFU1800
RFU1800
RFU1800
TCU TCU
SLPU SLPU
PMU PSU PSU PSU PMU PSU PSU PSU
PDU PDU
WBBP WBBP WBBP
WBBP
FAN
WBBP
FANc
GTMU
Install 3 new RRU2T2R 1800
UPEU
WBBP
UPEUd
UBBPe4
WBBP WMPT Install 3 new SET of Combiner WBBP UMPT
Remove WMPT and GTMU then add add UMPT at slot 7 (from H3I WH)
Add 1 pcs UBBPe4 at slot 2
Replace existing UPUE with 1 pcs UPEUd
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
Replace existing FANa with FANc
Move 1 pcs WBBP from slot 2 to available slot (if any)
Install Dummy BBU Cover 1 pcs
BOTTOM OF RACK Install 3 pcs Dummy RFU Cover BOTTOM OF RACK
TCU TCU
SLPU SLPU
PMU PSU PSU PSU PMU PSU PSU PSU
PDU PDU
WBBP WBBP WBBP
WBBP
FANc
WBBP
FANc
GTMU
UPEU
WBBP
UPEUd
UBBPe4
WBBP WMPT Install 3 new RRU2T2R 1800 WBBP UMPT
Dismantle 3 pcs existing 2G RFU
Remove WMPT and GTMU then add add UMPT at slot 7 (from H3I WH)
Add 1 pcs UBBPe4 at slot 2
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
RFU1800
RFU1800
RFU1800
TCU TCU
SLPU SLPU
PMU PSU PSU PSU PMU PSU PSU PSU
PDU PDU
WBBP WBBP WBBP
WBBP
FANc
WBBP
FANc
GTMU
UPEU
WBBP
UPEUd
UBBPe4
WBBP WMPT Install 3 new RRU2T2R 1800 WBBP UMPT
Install 3 SET of Combiner
Remove WMPT and GTMU then add add UMPT at slot 7 (from H3I WH)
Add 1 pcs UBBPe4 at slot 2
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
Move 1 pcs WBBP from slot 2 to available slot (if any)
Install Dummy BBU Cover 1 pcs
Install 3 pcs Dummy RFU Cover
BOTTOM OF RACK BOTTOM OF RACK
PDU PDU
FANc
WBBP
FANc
GTMU
UPEUd
UBBPe4
UPEU
WBBP
WBBP WMPT WBBP UMPTb2 Install New 2 pcs RRU1800 2T2R
Install 2 New SET of Combiner
DCDU DCDU
FMU FMU Remove WMPT and add UMPT at slot 7 (from H3I WH)
Add 1 pcs UBBPe4 at slot 2
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
3G RRU
BTS3900A Ver. B AC type 3G RRU BTS3900A Ver. B AC type
TCU TCU
SLPU SLPU
PMU PSU PSU PSU PMU PSU PSU PSU
PDU PDU
WBBP WBBP WBBP
WBBP
FANc
WBBP
FANc
GTMU Remove WMPT and GTMU then add UMPT at slot 7 (from H3I WH)
UPEUc
UPEUd
WBBP UBBPe4
WBBP WMPT WBBP UMPT Move 1 pcs WBBP from slot 2 to available slot (if any)
Add 1 pcs UBBPe4 at slot 2
Replace existing UPUE with 1 pcs UPEUd
Install New 3 pcs RRU1800
Install New 1 set Antenna RF
Install 2 New Combiner
Install Dummy BBU Cover 1 pcs
3G RRU
BTS3900A Ver. B AC type 3G RRU BTS3900A Ver. B AC type
TCU TCU
SLPU SLPU
PMU PSU PSU PSU PMU PSU PSU PSU
PDU PDU
WBBP WBBP WBBP
WBBP
FANc
WBBP
FANc
GTMU Remove WMPT and GTMU then add UMPT at slot 7 (from H3I WH)
UPEUc
UPEUd
WBBP UBBPe4
WBBP WMPT WBBP UMPT Move 1 pcs WBBP from slot 2 to available slot (if any)
Add 1 pcs UBBPe4 at slot 2
Replace existing UPUE with 1 pcs UPEUd
Install New 3 pcs RRU1800
Install New 2 set Antenna RF
Install 1 New Combiner
Install Dummy BBU Cover 1 pcs
BTS3900A
RRU 1T2R 2100
BTS3900A RRU 1T2R 2100
TCU TCU
SLPU SLPU
PDU PDU
FANc
WBBP
FANc
GTMU
UPEUd
UBBPe4 Install New 3 pcs RRU1800 2T2R
UPEU
WBBP
WBBP WMPT WBBP UMPTb2
Install New 3 SET of Combiner
DCDU
Remove WMPT and add UMPT at slot 7 (from H3I WH)
DCDU
FMU FMU Add 1 pcs UBBPe4 at slot 2
U2100 WRFU
U2100 WRFU
BTS3900A
RRU 1T2R 2100
BTS3900A
TCU TCU
SLPU SLPU
PDU PDU
FANc
WBBP
FANc
GTMU
UPEUd
UBBPe4 Install New 3 pcs RRU1800 2T2R
UPEU
WBBP
WBBP WMPT WBBP UMPTb2
Dismantle 2 pcs of GRFU
DCDU
Dismantle 2 pcs of RRU 1T2R 1800
DCDU
FMU FMU Remove WMPT and add UMPT at slot 7 (from H3I WH)
U2100 WRFU
U2100 WRFU
U2100 WRFU
U2100 WRFU
RFU1800
TCU TCU
SLPU SLPU
PDU PDU
FANc
WBBP
FAN
GTMU
UPEUd
UBBPe4 Add 1 pcs UBBPe4 at slot 2
UPEU
WBBP
WBBP WMPT WBBP UMPTb2
Replace existing UPUE with 1 pcs UPEUd
Replace CPRI cable for GRFU and SFP connector for RRU
DCDU DCDU
FMU FMU Replace existing FANa with FANc
GL1800 MRFU
U2100 WRFU
Move 1 pcs WBBP from slot 2 to available slot (if any)
U2100 WRFU
G1800 GRFU
UPEUd
Running script command to configure from SIMO to MIMO Partner 2G&3G Down