Sie sind auf Seite 1von 20

www.huawei.

com

SOP for H3I NEFPA H2 Batch 2-2018 345 Sites

HUAWEI TECHNOLOGIES CO., LTD.


Content

 Scope of Work
 Site Solution
 Additional Work
 Implementation Flow and Checklist

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 2


Scope of Work – Wireless
Scenario Quantity
Region Quantity
1.1a Reuse Existing GRFU Board - FAN 32
1.1b Reuse Existing GRFU Board 173 Central Java 113
1.2a Reuse Existing RRU 5 Central-East Kalimantan 25
2.1a New RRU - FAN 22
Jabodetabek 78
2.1b New RRU 95
2.1c New RRU 2IBC 1 North Sulawesi 5
2.1d New RRU - IBC2M 2 to 3 Sector 7 South East Sumatera 9
2.1e New RRU - IBC2M 1 to 3 Sector 4
3.1c New RRU 1IBC+2IBC2M 1 South West Sumatera 12
3.1d New RRU 2IBC+2IBC2M 1 West Java 86
3.2a Reuse GRFU 1IBC+2IBC2M 2
West Kalimantan 17
4.1 LTE AAU 2
Grand Total 345 Grand Total 345

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 3


Scope of Work - Power

Solution Quantity

Add 1x100Ah Battery 3

Add 1x30A 2U PSU 18

Add 1x30A 2U PSU + add 2x100Ah Battery 1

Proposed New TP48200A + 2x100Ah Battery 8

Grand Total 30

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 4


Scenario 1.1a Add L18 SIMO – Reuse GRFU/MRFU – With Additional FANc (32 Sites)

BTS3900A BTS3900A
Remove WMPT and GTMU then add UMPT at slot 7 (from H3I WH)
TCU TCU Add 1 pcs UBBPe4 at slot 2
SLPU SLPU Replace existing UPUE with 1 pcs UPEUd
Replace existing FANa with FANc
PMU PSU PSU PSU PMU PSU PSU PSU
Move 1 pcs WBBP from slot 2 to available slot (if any)
PDU PDU Replace 3 pcs existing CPRI 2G RFU with new one
Install Dummy BBU Cover 1 pcs
WBBP WBBP WBBP
Replace 1/2/3 pcs DRFU to MRFU (if any)
WBBP

FANc
WBBP
FAN

GTMU

UPEUd
UBBPe4
UPEU

WBBP
WBBP WMPT WBBP UMPT

DCDU DCDU
FMU FMU
GL1800 MRFU

GL1800 MRFU

GL1800 MRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU
G1800 GRFU

G1800 GRFU

G1800 GRFU

BOTTOM OF RACK BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 5


Scenario 1.1b Add L18 SIMO – Reuse GRFU/MRFU – No Additional FANc (173 Sites)

BTS3900A BTS3900A
Remove WMPT and GTMU then add UMPT at slot 7 (from H3I WH)
TCU TCU Add 1 pcs UBBPe4 at slot 2
SLPU SLPU Replace existing UPUE with 1 pcs UPEUd
Move 1 pcs WBBP from slot 2 to available slot (if any)
PMU PSU PSU PSU PMU PSU PSU PSU
Replace 3 pcs existing CPRI 2G RFU with new one
PDU PDU Install Dummy BBU Cover 1 pcs
Replace 1/2/3 pcs DRFU to MRFU (if any)
WBBP WBBP WBBP
WBBP

FANc
WBBP
FANc

GTMU

UPEUd
UBBPe4
UPEU

WBBP
WBBP WMPT WBBP UMPT

DCDU DCDU
FMU FMU
GL1800 MRFU

GL1800 MRFU

GL1800 MRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU
U2100 WRFU

U2100 WRFU

U2100 WRFU
G1800 GRFU

G1800 GRFU

G1800 GRFU

BOTTOM OF RACK BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 6


Scenario 1.2a Add L18 SIMO – Reuse RRU (5 Sites)
RRU GL 1800 RRU GL 1800 3G RRU
3G RRU

BTS3900A Ver. B AC type BTS3900A Ver. B AC type

TCU TCU
SLPU SLPU
PMU PSU PSU PSU PMU PSU PSU PSU

PDU PDU
WBBP WBBP WBBP
WBBP
FANc

WBBP

FANc
GTMU
UPEUc

UPEUd
WBBP UBBPe4
WBBP WMPT WBBP UMPT
Remove WMPT and GTMU then add UMPT at slot 7 (from H3I
WH)
Move 1 pcs WBBP from slot 2 to available slot (if any)
Add 1 pcs UBBPe4 at slot 2
Replace existing UPUE with 1 pcs UPEUd
Replace SFP connector of 2G RRU on UBBP and on RRU 6 pcs
Install Dummy BBU Cover 1 pcs
BOTTOM OF RACK BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 7


Scenario 2.1a Add L18 SIMO Swap RFU to RRU – With Additional FANc (13
Sites)
RRU1800 2T2R
1st Condition: 2G Available

BTS3900A Ver. B AC type BTS3900A Ver. B AC type

TCU TCU
SLPU SLPU
PMU PSU PSU PSU PMU PSU PSU PSU

PDU PDU
WBBP WBBP WBBP
WBBP
FAN

WBBP

FANc
GTMU
Install 3 new RRU2T2R 1800
UPEU

WBBP

UPEUd
UBBPe4
WBBP WMPT Dismantle 3 pcs existing 2G RFU WBBP UMPT
Remove WMPT and GTMU then add add UMPT at slot 7 (from H3I WH)
Add 1 pcs UBBPe4 at slot 2
Replace existing UPUE with 1 pcs UPEUd
U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU
Replace existing FANa with FANc
RFU1800

RFU1800

RFU1800

Move 1 pcs WBBP from slot 2 to available slot (if any)


Install Dummy BBU Cover 1 pcs
BOTTOM OF RACK Install 3 pcs Dummy RFU Cover BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 8


Scenario 2.1a Add L18 SIMO Swap RFU to RRU – With Additional FANc (10
Sites)
RRU1800 2T2R
2nd Condition: 2G N/A

BTS3900A Ver. B AC type BTS3900A Ver. B AC type

TCU TCU
SLPU SLPU
PMU PSU PSU PSU PMU PSU PSU PSU

PDU PDU
WBBP WBBP WBBP
WBBP
FAN

WBBP

FANc
GTMU
Install 3 new RRU2T2R 1800
UPEU

WBBP

UPEUd
UBBPe4
WBBP WMPT Install 3 new SET of Combiner WBBP UMPT
Remove WMPT and GTMU then add add UMPT at slot 7 (from H3I WH)
Add 1 pcs UBBPe4 at slot 2
Replace existing UPUE with 1 pcs UPEUd
U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU

U2100 WRFU
Replace existing FANa with FANc
Move 1 pcs WBBP from slot 2 to available slot (if any)
Install Dummy BBU Cover 1 pcs
BOTTOM OF RACK Install 3 pcs Dummy RFU Cover BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 9


Scenario 2.1b Add L18 SIMO Swap RFU to RRU – Without Additional FANc
(31 Sites)
RRU1800 2T2R
1st Condition: 2G Available

BTS3900A Ver. B AC type BTS3900A Ver. B AC type

TCU TCU
SLPU SLPU
PMU PSU PSU PSU PMU PSU PSU PSU

PDU PDU
WBBP WBBP WBBP
WBBP
FANc

WBBP

FANc
GTMU
UPEU

WBBP

UPEUd
UBBPe4
WBBP WMPT Install 3 new RRU2T2R 1800 WBBP UMPT
Dismantle 3 pcs existing 2G RFU
Remove WMPT and GTMU then add add UMPT at slot 7 (from H3I WH)
Add 1 pcs UBBPe4 at slot 2
U2100 WRFU

U2100 WRFU

U2100 WRFU

Replace existing UPUE with 1 pcs UPEUd

U2100 WRFU

U2100 WRFU

U2100 WRFU
RFU1800

RFU1800

RFU1800

Move 1 pcs WBBP from slot 2 to available slot (if any)


Install Dummy BBU Cover 1 pcs
Install 3 pcs Dummy RFU Cover
BOTTOM OF RACK BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 10


Scenario 2.1b Add L18 SIMO Swap RFU to RRU – Without Additional FANc
(74 Sites)
RRU1800 2T2R
2nd Condition: 2G N/A

BTS3900A Ver. B AC type BTS3900A Ver. B AC type

TCU TCU
SLPU SLPU
PMU PSU PSU PSU PMU PSU PSU PSU

PDU PDU
WBBP WBBP WBBP
WBBP
FANc

WBBP

FANc
GTMU
UPEU

WBBP

UPEUd
UBBPe4
WBBP WMPT Install 3 new RRU2T2R 1800 WBBP UMPT
Install 3 SET of Combiner
Remove WMPT and GTMU then add add UMPT at slot 7 (from H3I WH)
Add 1 pcs UBBPe4 at slot 2
U2100 WRFU

U2100 WRFU

U2100 WRFU

Replace existing UPUE with 1 pcs UPEUd

U2100 WRFU

U2100 WRFU

U2100 WRFU
Move 1 pcs WBBP from slot 2 to available slot (if any)
Install Dummy BBU Cover 1 pcs
Install 3 pcs Dummy RFU Cover
BOTTOM OF RACK BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 11


Scenario 2.1c Add L18 SIMO Use New RRU – IBC 2 Sector (1 site)
BTS3900A BTS3900A
RRU GL 2T2R1800
TCU TCU
SLPU SLPU

PMU PSU PSU PSU PMU PSU PSU PSU

PDU PDU

WBBP WBBP WBBP


WBBP

FANc
WBBP
FANc

GTMU

UPEUd
UBBPe4
UPEU

WBBP
WBBP WMPT WBBP UMPTb2 Install New 2 pcs RRU1800 2T2R
Install 2 New SET of Combiner
DCDU DCDU
FMU FMU Remove WMPT and add UMPT at slot 7 (from H3I WH)
Add 1 pcs UBBPe4 at slot 2

U2100 WRFU

U2100 WRFU
U2100 WRFU

U2100 WRFU

Replace existing UPUE with 1 pcs UPEUd


Move 1 pcs WBBP from slot 2 to available slot (if any)
BOTTOM OF RACK BOTTOM OF RACK Install Dummy BBU Cover 1 pcs

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 12


Scenario 2.1d Add L18 SIMO – 2.1d New RRU - IBC2M 2 to 3 Sector (7 Sites)
RRU L 1800

3G RRU
BTS3900A Ver. B AC type 3G RRU BTS3900A Ver. B AC type

TCU TCU
SLPU SLPU
PMU PSU PSU PSU PMU PSU PSU PSU

PDU PDU
WBBP WBBP WBBP
WBBP
FANc

WBBP

FANc
GTMU Remove WMPT and GTMU then add UMPT at slot 7 (from H3I WH)
UPEUc

UPEUd
WBBP UBBPe4
WBBP WMPT WBBP UMPT Move 1 pcs WBBP from slot 2 to available slot (if any)
Add 1 pcs UBBPe4 at slot 2
Replace existing UPUE with 1 pcs UPEUd
Install New 3 pcs RRU1800
Install New 1 set Antenna RF
Install 2 New Combiner
Install Dummy BBU Cover 1 pcs

BOTTOM OF RACK BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 13


Scenario 2.1e Add L18 SIMO – 2.1d New RRU - IBC2M 1 to 3 Sector (4 Sites)
RRU L 1800

3G RRU
BTS3900A Ver. B AC type 3G RRU BTS3900A Ver. B AC type

TCU TCU
SLPU SLPU
PMU PSU PSU PSU PMU PSU PSU PSU

PDU PDU
WBBP WBBP WBBP
WBBP
FANc

WBBP

FANc
GTMU Remove WMPT and GTMU then add UMPT at slot 7 (from H3I WH)
UPEUc

UPEUd
WBBP UBBPe4
WBBP WMPT WBBP UMPT Move 1 pcs WBBP from slot 2 to available slot (if any)
Add 1 pcs UBBPe4 at slot 2
Replace existing UPUE with 1 pcs UPEUd
Install New 3 pcs RRU1800
Install New 2 set Antenna RF
Install 1 New Combiner
Install Dummy BBU Cover 1 pcs

BOTTOM OF RACK BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 14


Scenario 3.1c Add L18 SIMO Use New RRU – 1 Sec IBC – 2 Sec IBC2M (1 site)
RRU1800 2T2R

BTS3900A
RRU 1T2R 2100
BTS3900A RRU 1T2R 2100
TCU TCU
SLPU SLPU

PMU PSU PSU PSU PMU PSU PSU PSU

PDU PDU

WBBP WBBP WBBP


WBBP

FANc
WBBP
FANc

GTMU

UPEUd
UBBPe4 Install New 3 pcs RRU1800 2T2R
UPEU

WBBP
WBBP WMPT WBBP UMPTb2
Install New 3 SET of Combiner

DCDU
Remove WMPT and add UMPT at slot 7 (from H3I WH)
DCDU
FMU FMU Add 1 pcs UBBPe4 at slot 2

U2100 WRFU
U2100 WRFU

Replace existing UPUE with 1 pcs UPEUd


Move 1 pcs WBBP from slot 2 to available slot (if any)
Install Dummy BBU Cover 1 pcs
BOTTOM OF RACK BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 15


Scenario 3.1d Add L18 SIMO Use New RRU – 2 Sec IBC – 2 Sec IBC2M (1 site)
RRU 1T2R 1800 RRU1800 2T2R
RRU 1T2R 2100

BTS3900A
RRU 1T2R 2100
BTS3900A

TCU TCU
SLPU SLPU

PMU PSU PSU PSU PMU PSU PSU PSU

PDU PDU

WBBP WBBP WBBP


WBBP

FANc
WBBP
FANc

GTMU

UPEUd
UBBPe4 Install New 3 pcs RRU1800 2T2R
UPEU

WBBP
WBBP WMPT WBBP UMPTb2
Dismantle 2 pcs of GRFU

DCDU
Dismantle 2 pcs of RRU 1T2R 1800
DCDU
FMU FMU Remove WMPT and add UMPT at slot 7 (from H3I WH)

U2100 WRFU

U2100 WRFU
U2100 WRFU

U2100 WRFU

Add 1 pcs UBBPe4 at slot 2


RFU1800

RFU1800

Replace existing UPUE with 1 pcs UPEUd


Move 1 pcs WBBP from slot 2 to available slot (if any)
BOTTOM OF RACK BOTTOM OF RACK
Install Dummy BBU Cover 1 pcs
Install 2 pcs Dummy RFU panel

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 16


Scenario 3.2a Add L18 SIMO Re-use GRFU/RRU – 1 Sec IBC – 2 Sec IBC2M (2
site)
RRU 1T2R 1800
RRU 1T2R 2100
RRU1800 GL 1T2R
BTS3900A
RRU 1T2R 2100
BTS3900A

TCU TCU
SLPU SLPU

PMU PSU PSU PSU PMU PSU PSU PSU

PDU PDU

WBBP WBBP WBBP


Remove WMPT and add UMPT at slot 7 (from H3I WH)
WBBP

FANc
WBBP
FAN

GTMU

UPEUd
UBBPe4 Add 1 pcs UBBPe4 at slot 2
UPEU

WBBP
WBBP WMPT WBBP UMPTb2
Replace existing UPUE with 1 pcs UPEUd
Replace CPRI cable for GRFU and SFP connector for RRU
DCDU DCDU
FMU FMU Replace existing FANa with FANc

GL1800 MRFU

U2100 WRFU
Move 1 pcs WBBP from slot 2 to available slot (if any)
U2100 WRFU
G1800 GRFU

Install Dummy BBU Cover 1 pcs

BOTTOM OF RACK BOTTOM OF RACK

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 17


Scenario 4.1 Add L18 SIMO AAU (2 Sites)

AAU AAU AAU AAU AAU AAU


3940 3940 3940 3940 3940 3940
(U) (U) (U) (UL) (UL) (UL)

UPEUd

Add 1 pcs UBBPe4 at Slot 2


Replace existing UPEU with UPEUd
Download 4G Software
Add LTE1800 configuration remotely

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 18


Implementation Checklist
Down time implementation
Activity PIC Impact 30 Min 30 Min 30 Min 30 Min

Turn off Existing RFU Partner 2G&3G Down

Move Existing MRFU/WRFU to new RF Cabinet Partner 2G&3G Down

Connect RF Cross cable between MRFU/WRFU Partner 2G&3G Down

Move Combiner from Ground to Top Partner 2G&3G Down

Re-connect Jumper 2G&3G Down

Inform to BSS for installation done. Partner 2G&3G Down

Running script command to configure from SIMO to MIMO Partner 2G&3G Down

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 19


Thank you
www.huawei.com

Copyright©2011 Huawei Technologies Co., Ltd. All Rights Reserved.


The information contained in this document is for reference purpose only, and is subject to
change or withdrawal according to specific customer requirements and conditions.

Das könnte Ihnen auch gefallen