TD-LTE Power Configuration

Author/ Email: Ray Khastur


Version: V1.0 (20140106)
Basic Principle
How to Calculate RS

3
Kind of Symbol

4
PB Explanation

*PB 0 is mean there is no increment on CRS RE it’s mean non power boosting, but PDSCH power increase to 5/4.
*By using PB 1, the RS Power increase on CRS RE two units it’s mean about power boosting and PDSCH power on symbol type B
same.
*By using PB 3, the RS Power increase on CRS RE 4 units it’s mean about power boosting and PDSCH power on symbol type B
reduce half than PB 1.

5
Simulation Result
RSRP with PB : 1

7
RSRP with PB : 3

8
RSRP Comparison

In this simulation one site have configuration of 10 MHz and all cell’s using RS Power 15.2 dBm with different PB configuration.

From Simulation single site there is no difference between PB 1 and PB 3 usage in coverage plot.
But from Power Consumption Calculation PB 1 will used around 10 W on each port of RRU.
And For PB 3 will used around 5 W on each port of RRU.

9
SINR with PB : 1

10
SINR with PB : 3

11
SINR Comparison

From Simulation single site there is improvement of SINR > 0 dB around 3.65%

12
DL Throughput with PB : 1

13
DL Throughput with PB : 3

14
DL Throughput Comparison

From Simulation single site there is improvement of DL Throughput > 12.5 Mbps around 0.04 %
PB 3 in this simulation have 101.9 Kbps more
higher than PB 1 Average DL Throughput.

But Peak Throughput still same at 28.17 Mbps

15
Using RS Power 18.2 dBm
with PB 3
RSRP

17
RSRP Comparison

RS : 15.2 dBm RS : 18.2 dBm


PB : 1 PB : 3
Pwr : 10 W Pwr : 10 W

In this simulation one site have configuration of 10 MHz and all cell’s using different RS Power but with the same PB configuration .

18
SINR

19
SINR Comparison

From Simulation single site there is improvement of SINR > 0 dB around 9.51%

20
DL Throughput

Improve

Improve

Improve

21
DL Throughput Comparison

Compare with Average user Throughput for RS Power 15.2 dBm PB 1 which have same power
consumption, Average DL Throughput for 18.2 dBm PB3 have degraded 0.46% inside the polygon.
This degradation inline with the improvement of coverage outside the polygon.

22
Conclusion
Application of Power Boosting
 Power Boosting can be used in order to manipulate limited of
power that can be used for single carrier coverage not more
than half of capacity.
 Implementation of Power Boosting (PB) can be applicable for
area where site to site distance is more than 800 meter for
outer area, and can be used also in inner area if the
morphology of that area is mostly dominated with High Rise
Building, Dense of Ruko (House with Commercial area) with
more than 1 floor, this condition need additional site or we can
use more penetration power with PB implementation.

24