Design of Axial Long Column

Design Criteria Load Factors ф


f'c = 200 ksc DLf = 1.20 0.70
fy = 4000 ksc LLf = 1.60
Number of Bar
Column Data Staad Pro. Data Reduction Service Load Ultimate Load As 25 22 20 18 16
Column P ud
Floor b h Lu DL LL DL+LL 1.2DL+1.6LL R rg 2
ID Factor (ton) (cm ) (mm) (mm) (mm) (mm) (mm)
(m) (m) (m) (Ton) (Ton) (ton) (ton)
C1 (Foor)
4 0.20 0.20 3.2 4.2 0.92 1.00 5.12 6.512 0.64 10.122 0.0100 4.00 4 4 4 4 4
3 0.25 0.25 3.2 17.95 4.75 1.00 22.7 29.140 0.73 39.991 0.0100 6.25 4 4 4 4 4
2 0.25 0.25 3.2 37.92 7.76 1.00 45.68 57.920 0.73 79.488 0.0149 9.32 4 4 4 4 5
1 0.30 0.30 3.8 57.98 10.77 1.00 68.75 86.808 0.73 118.554 0.0170 15.33 4 5 5 7 8
Pier 0.30 0.30 2.00 71.84 11.02 1.00 82.86 103.840 0.89 116.384 0.0159 14.32 4 4 5 6 8

Design of Axial Long Column


Design Criteria Load Factors ф
f'c = 200 ksc DLf = 1.20 0.70
fy = 4000 ksc LLf = 1.60
Number of Bar
Column Data Staad Pro. Data Reduction Service Load Ultimate Load As 25 22 20 18 16
Column P ud
Floor b h Lu DL LL DL+LL 1.2DL+1.6LL R rg 2
ID Factor (ton) (cm ) (mm) (mm) (mm) (mm) (mm)
(m) (m) (m) (Ton) (Ton) (ton) (ton)
C2 (Foor)
4 0.20 0.20 3.2 3.34 0.47 1.00 4.1172 5.129 0.64 7.972 0.0100 4.00 4 4 4 4 4
3 0.25 0.25 3.2 15.97 2.66 1.00 19.11 23.996 0.73 32.931 0.0100 6.25 4 4 4 4 4
2 0.25 0.25 3.2 35.19 4.5 1.00 40.17 50.004 0.73 68.624 0.0100 6.25 4 4 4 4 4
1 0.30 0.30 3.8 54.17 6.75 1.00 61.7408 76.789 0.73 104.871 0.0100 9.00 4 4 4 4 5
Pier 0.30 0.30 2.00 63.65 6.76 1.00 70.842 87.714 0.89 98.310 0.0100 9.00 4 4 4 4 5
DL
LL
1.2DL+1.6LL
1.4DL+1.7LL
1.4DL+1.7LL