Sie sind auf Seite 1von 18

HERAEUS NOBLELIGHT FIGHT

AGAINST COVID-19
HNS Marketing Shanghai, March 2020
PROMOTION OF UV DURING CORONA VIRUS EPIDEMIC PERIOD
Participate 2 seminars through 3rd party online platform “Ming Class” in Feb.

2 06/05/2020 Heraeus Noblelight Fight against COVID-19 | HNS | Sales & Marketing
DONATION UV DISINFECTION LAMP AND FIXTURES

HNS Donated nearly 1300 sets of UV


disinfection lamp and fixtures to Hubei Province

› Feb.11th , HNS donated nearly 1000 set UV disinfection


modules to Huanggang, Hubei.

› Feb.19th , HNS donated nearly 300 set UV disinfection


modules to Xiaogan, Hubei.

3 06/05/2020 Heraeus Noblelight Fight against COVID-19 | HNS | Sales & Marketing
HERAEUS UV DISINFECTION ROBOT

› Feb.28th , HNS has sent the first prototype of UV


disinfection robot to Shanghai Public Health
Clinical Center in Jinshan for trial.

4 06/05/2020 Heraeus Noblelight Fight against COVID-19 | HNS | Sales & Marketing
HNS UV DISINFECTION PRODUCT PORTFOLIO IN DEVELOPING

G-Lamp UV UV air UV air


UV LAMP batten for air Disinfection Disinfection disinfection
disinfection Mobile Cart ROBOT unit & system

Description
› This text can be replaced with your
own text.
› All phrases can be replaced with your
own text.

5 06/05/2020 Heraeus Noblelight Fight against COVID-19 | HNS | Sales & Marketing
UV LAMP

Note : The UV lamp is suitable for installation in 1.2m


long fluorescent lamp holder.
Rough IC price : USD14.00

6 06/05/2020 Heraeus Noblelight Fight against COVID-19 | HNS | Sales & Marketing
G-LAMP BATTEN FOR AIR DISINFECTION Rough IC price : USD32.00
STANDARD G-LAMP BATTEN WITH INFRA-SENSOR, AND PLUS CABLE. INCLUDE LAMP

Product Identification Product Spec

• Flexible installation : the bracket can be ceiling-mounted


Infra-sensor
or hoisted installation. Refer to the figure below right;
• Infra-sensor : Start-up delay is 30s. Turn off the lights
immediately when someone accidentally breaks in ;
delay start-up & intruding-off • Large-scale detection : Infrared sensing coverage range
8-12 meters ;
 Type : HAD-BI 36W • Disinfection time: Recommend UV lamps keep on over
 Power Supply : ~220V/50Hz/50W 30mins for each disinfection ;
 Dimension : L=1330mm, W=41mm, H=73.5mm • Killing rate of Virus and Bacteria : 99.9%;
 UVC output : 253.7nm • Application area: Hospitals, schools, homes, public toilets
 UVC intensity : 135μW/cm2 @1m
and other places that need disinfection.
 Protection mode : Infrared Induction

7 06/05/2020 Heraeus Noblelight Fight against COVID-19 | HNS | Sales & Marketing
G-LAMP BATTEN FOR AIR DISINFECTION
STANDARD G-LAMP BATTEN WITH INFRA-SENSOR, AND PLUS CABLE.

How to Use Application Examples

Infra-sensor
 Wall switches, nails and
rope are prepared by
yourself

delay start-up & intruding-off

 Install the UV lamp batten on the wall or ceiling with nail and rope
 Use a wall switch to turn on/off UV lamps
 When its switched on, UV lamp will be delay-started in 30s in order to let
 G-lamp battens installed on
operator left the room safely;
room ceiling
 The UV lamp will be switched off automatically for 30s if some-body
intrudes the room where UV lamps are working, and then you can turn
off the wall switch to shut down the power for UV lamps.

8 06/05/2020 Heraeus Noblelight Fight against COVID-19 | HNS | Sales & Marketing
UV DISINFECTION MOBILE CART Rough IC price : USD145.00
DIRECT UV , INCLUDE LAMPS

Product Identification Product Spec

• Caster structure: 4 pcs 360-degree wheels at bottom, easy


 Type : HAD-CR02 to move;
 Power Supply : ~220V/50Hz/100W • Folding design: UV lamp can be extended / folded, easy to
 Dimension : H=1120mm, bottom be stored;
size=410*420mm • Timing function: Set the UV lamp disinfection time 0~60
 UVC output : 253.7nm min, and automatically turn off the UV lamp when the set
 UVC intensity : 135μW/cm2 @1m value is reached;
 Adjustable angle of UV rack : 0-180 degree • Killing rate of Virus and Bacteria : 99.9%;
• Application area: Hospitals, schools, cafeterias, shopping
malls, hotels, public toilets and other places that need
disinfection.

9 06/05/2020 Heraeus Noblelight Fight against COVID-19 | HNS | Sales & Marketing
UV DISINFECTION MOBILE CART
DIRECT UV

How to Use Application Examples

 Move the UV cart to the space where is need to be disinfected;


 UV cart for disinfection of dinning room
 Open protection cover and pull out UV-lamp rack and keep it at certain
and classroom
height;
 Plug the three-pin plug into the socket and make sure power is given to the  UV disinfection cart is popular at hospital
socket;
 Rotated the timer knob to suitable time, e.g. 30min;
 Switch on UV lamps by the green button on panel, and then UV lamp will be
on in 10s, operator must be leave UV irradiation area before UV lamps on;
 UV lamps will be off automatically when it gets setting time, e.g. 30min

Switch on/off
Timer knob
Fuse 1#
Fuse 2#

10 06/05/2020 Presentation
Heraeus Noblelight
title | Author
Fight against
| Department
COVID-19 | HNS | Sales & Marketing
UV AIR DISINFECTION ROBOT Rough IC price : USD27,500.00 ( 1-20 systems)
DIRECT UV

Product Identification Product Spec

• Easy to users: No any identification in advance, fast launch


 Type : HAD-RR
out on site;
 Power Supply : ~220V/50Hz/1000W
• Robot model: Fully autonomous positioning and navigation,
 Dimension : Φ600 x 1600 mm
autonomous charging, anti-dumping, and obstacle
 UVC output : 253.7nm avoidance for mobile person;
 Operation model: Smart robot setting • Background operation: Pre-set disinfection tasks and
model route, power monitoring by APP;

 Operation speed : max. 1m/s • UV exposure: Through direct UV exposure to disinfect of

 Endurance : 3~5 hours polluted air and object surfaces around UV robot;
• Killing rate of Virus and Bacteria : 99.9%;
• Application area : Hospitals, schools, cafeterias, shopping
malls, hotels, public toilets and other places that need
disinfection.

11 06/05/2020 Heraeus Noblelight Fight against COVID-19 | HNS | Sales & Marketing
UV AIR DISINFECTION ROBOT
DIRECT UV

How to Use

Set disinfect-time

Set disinfect-place

1, Set disinfection time & place & working 2, UV robot will perform the task
model via terminal system; according to pre-set instruction;

3, UV robot start disinfection after it


…… completes detection in the field
automatically;
5, Return to the station for charging automatically 4, UV robot complete task and perform next instruction
after completing all tasks. according to pre-setting value ;
12 06/05/2020 Presentation
Heraeus Noblelight
title | Author
Fight against
| Department
COVID-19 | HNS | Sales & Marketing
UV AIR DISINFECTION ROBOT Rough IC price : USD29,800.00 ( 1-20 systems)
AIR DISINFECTION

Product Identification Product Spec

 Type : HAD-RF • Easy to users: No any identification in advance, fast launch

 Power Supply : ~220V/50Hz/1000W out on site;


• Robot model: Fully autonomous positioning and navigation,
 Dimension : Φ600 x 1600 mm
autonomous charging, anti-dumping, and obstacle
 UVC output : 253.7nm
avoidance for mobile person;
 Operation model: Smart robot setting • Background operation: Pre-set disinfection tasks and
model route, power monitoring by APP;
 Operation speed : max. 1m/s • UV disinfection: Air flow in the UV irradiation chamber from
 Endurance : 3~5 hours bottom and flow out at top side;
• Killing rate of Virus and Bacteria : 99.9%;
• Application area : Hospitals, schools, cafeterias, shopping
malls, hotels, public toilets and other places that need
disinfection.

13 06/05/2020 Heraeus Noblelight Fight against COVID-19 | HNS | Sales & Marketing
UV AIR DISINFECTION ROBOT
AIR DISINFECTION

How to Use

Set disinfect-time

Set disinfect-place

1, Set disinfection time & place & working 2, UV robot will perform the task
model via terminal system; according to pre-set instruction;

3, UV robot start disinfection after it


…… completes detection in the field
automatically;
5, Return to the station for charging auto- 4, UV robot complete task and perform next instruction
matically after completing all tasks. according to pre-setting value ;
14 06/05/2020 Presentation
Heraeus Noblelight
title | Author
Fight against
| Department
COVID-19 | HNS | Sales & Marketing
HERAEUS SMART UV ROBOT ON GOING

UV ROBOT HAD-RF UV ROBOT HAD-RR

Debugging Piolet run in hospital Debugging Ready for Delivery

15 06/05/2020 Heraeus Noblelight Fight against COVID-19 | HNS | Sales & Marketing
UV AIR DISINFECTION UNIT Rough IC price : customized
FOR COMMERCIAL AIR CONDITION AT CONDITIONING SYSTEM

Product Identification Product Spec

 Series : Cold Air Disinfection (CAD)


• Biofilm removal increases heat transfer capacity, and
 Power Supply : ~220V/50Hz/50-300W
reduces energy consumption;
 UVC output : 253.7nm
• UVC light destroys airborne viruses, mould and bacteria in
 Disinfection model: Killing bacteria on cooling
the circulating air;
coil/filers/air flow • CAD unit provide a high dosage of UVC light whilst operating
 Killing rate :≥ 99.9%
in a cold airstream (4 - 7°C);
• Customer Benefits:

Significant reduction of buildings energy and emissions
profile

Improved indoor air quality
After UV 
Extension of HVAC lifespan

Reduction in maintenance costs

Short ROI (return on investment)

16 06/05/2020 Heraeus Noblelight Fight against COVID-19 | HNS | Sales & Marketing
UV AIR DISINFECTION UNIT
FOR COMMERCIAL AIR CONDITION AT CONDITIONING SYSTEM

Application Examples

 UVC CAD unit was installed in the buildings HVAC AHU’s ;  CAD unit is also installed with its ceramic flange base;

 Tailored bracket for installation of CAD unit is necessary according to field  Make a hole at duct wall before installation

situation;  Push CAD sleeve in the hole and keep the sleeve at

 Ballast box is installed outside of AHU/air flow duct. another terminal with bracket;
 Fix flanges with nails.

17 06/05/2020 Heraeus Noblelight Fight against COVID-19 | HNS | Sales & Marketing
UV AIR DISINFECTION SYSTEM Rough IC price : customized
FOR COMMERCIAL AIR CONDITION. CUSTOMIZED DESIGN BASED ON PROJECT
Product Identification Product Spec

 Series : Air Disinfection Module • Customized design for each project;


 Power Supply : ~220V/50Hz/3kw-90kw • UVC light destroys airborne viruses, mould and bacteria in
 UVC output : 253.7nm the circulating/flowing air;
 Disinfection model: Killing bacteria in flowing air • Application area : Hospitals, schools, cafeterias, shopping
 Killing rate :≥ 99%, depend on UV system malls, hotels, public toilets, workshops and other places
design that need disinfection.

18 06/05/2020 Heraeus Noblelight Fight against COVID-19 | HNS | Sales & Marketing

Das könnte Ihnen auch gefallen