Sie sind auf Seite 1von 34

Project Administration

Power Transmission
and Distribution

©
Siemens AG 2006
Power Transmission and Distribution Service

DIGSI 4 System and Device Management

Installing DIGSI 4

Managing Projects

Working with the Devices

Optimizing Parameterization

Project Administration 02.1_A0


PTD-SE/ 2
Power Transmission and Distribution Service

DIGSI 4 Installation

Installation from CD
DIGSI 4 components
SIPROTEC 4 device drivers

Steps
Start Windows
Insert CD to start installation process
Enter the license number from product card
Select the components

Start DIGSI 4 via the Start menu

Project Administration 02.1_A0


PTD-SE/ 3
Power Transmission and Distribution Service

DIGSI 4 - The Structure of Projects in the DIGSI 4 Manager

System component hierarchy at your convenience

Project
System
Station
Feeder
Device
Modems
Phone Book

Project Administration 02.1_A0


PTD-SE/ 4
Power Transmission and Distribution Service

DIGSI 4 - New Project

Select the corresponding


dialog box
Enter project name
Define storage location

Project Administration 02.1_A0


PTD-SE/ 5
Power Transmission and Distribution Service

DIGSI 4 - Folders

Basic structure

Folders can contain the following objects

Further folders
SIPROTEC 4 devices
V3/V2 devices
SIPROTEC 4 versions
Modem connections

Project Administration 02.1_A0


PTD-SE/ 6
Power Transmission and Distribution Service

DIGSI 4 - Project Structure

Project Administration 02.1_A0


PTD-SE/ 7
Power Transmission and Distribution Service

Exercise:
Create & structure project - Part I

Create a new project („Project 1“).


Insert the folders (hierarchie levels) like in
the shown structure with the according
names.

Project Administration 02.1_A0


PTD-SE/ 8
Power Transmission and Distribution Service

DIGSI 4 - Insert Device

Open device catalog


Select device
Drag & Drop the device in
the project structure

Project Administration 02.1_A0


PTD-SE/ 9
Power Transmission and Distribution Service

DIGSI 4 - Device Specification

Properties

Project Administration 02.1_A0


PTD-SE/ 10
Power Transmission and Distribution Service

Exercise:
Create & structure project - Part II

Insert the following SIPROTEC 4 relays:


 Region North:
Relay on the table
 Substation 1: 7SJ610
V4.0
 Feeder 1: 7SJ622
V4.1
 Feeder 2: 7SJ622
V4.1
7SJ631
V4.1
Modem
connection
Project Administration 02.1_A0
PTD-SE/ 11
Power Transmission and Distribution Service

DIGSI 4 - Administrate V2/V3 Device

In DIGSI 4
Manager
SIPROTEC relays
of recent releases
(V2, V3) can be
administrated:
Before inserting
they have to be
generated in
DIGSI V3.

Project Administration 02.1_A0


PTD-SE/ 12
Power Transmission and Distribution Service

DIGSI 4 - Administration of V3-Projects

In DIGSI 4 Manager projects of recent releases (V3 DIGSI-projects) can be


administrated:
Before inserting they have to be generated in DIGSI V3.
Project Administration 02.1_A0
PTD-SE/ 13
Power Transmission and Distribution Service

Exercise:
Create & structure project - Part III

Insert an older relay into the folder „Feeder


6th Avenue“.

Project Administration 02.1_A0


PTD-SE/ 14
Power Transmission and Distribution Service

DIGSI 4 - Object Properties

SIPROTEC 4
Device
properties

Project Administration 02.1_A0


PTD-SE/ 15
Power Transmission and Distribution Service

DIGSI 4 - Object properties of V2/V3 relays

V2/V3 Device
Properties

Project Administration 02.1_A0


PTD-SE/ 16
Power Transmission and Distribution Service

DIGSI 4 - Save Project / Close

Save project

Save as...

- with / without rearrangement


- define storage location
Save

Close project

Project Administration 02.1_A0


PTD-SE/ 17
Power Transmission and Distribution Service

Exercise: DIGSI 4 - Save / copy / delete

Create a new project („Project 2“) an


Copy the folder „Substation 2“ from the first project („Project 1“) into
the new project.
Insert a new folder with the name „110 kV“ in the folder
„substation 2“.
Copy the folders „Feeder 1“ and „Feeder 2“ from the first project
(„Project 1“).
Move the relay „7SJ631 V4.1“ from „Feeder 2“ to „Feeder 1“
Delete the relay „7SJ622“ in „Feeder 2“.
Insert a new relay of the type „7SJ610 V4.0“.
Spezificate the order numer MLFB and look on the object
properties.

Project Administration 02.1_A0


PTD-SE/ 18
Power Transmission and Distribution Service

DIGSI 4 - Open Projects

Menu item File  Open


Automatic presetting
after Program start
(global default setting)
Latest edited projects
Hidden / moved

Project Administration 02.1_A0


PTD-SE/ 19
Power Transmission and Distribution Service

DIGSI 4 - Archiving / Retrieving of Projects

Project archivation - first steps

Make basic settings


- Select the archiving program of your choice
- Set folder to archiving / retrieving

Configuration of archiving program


- Archive beyond floppy disk
- Consistency check
- Overwriting of objects with identical names
- Automatic creation of archive path

Project Administration 02.1_A0


PTD-SE/ 20
Power Transmission and Distribution Service

DIGSI 4 - Archiving / Retrieving of Projects

Basic settings

Archiving
Retrieving

Project Administration 02.1_A0


PTD-SE/ 21
Power Transmission and Distribution Service

DIGSI 4 - Project Archiving

Project archiving

Project Administration 02.1_A0


PTD-SE/ 22
Power Transmission and Distribution Service

DIGSI 4 - Retrieving Projects

Retrieving projects

Select archive/source
Select a destination

Project Administration 02.1_A0


PTD-SE/ 23
Power Transmission and Distribution Service

DIGSI 4 - Delete / Reorganize Projects

Delete projects

individual
several

Reorganize projects

Project Administration 02.1_A0


PTD-SE/ 24
Power Transmission and Distribution Service

Exercise:
Archive/Delete/Retrieve

Archive the projekt „Project 1“ into the file system


(„C:\Floppy“).
Delete the Projekt „Project 1“
Close the project „Project 2“ und reopen it.
Retrieve the archived project „Project 1“ from the file system.

Project Administration 02.1_A0


PTD-SE/ 25
Power Transmission and Distribution Service

DIGSI 4 - Optimization and Parameterization

Use of functions beyond the projects:

Copy
Move
Model parameterization

for objects
Project
Folder
Device

Project Administration 02.1_A0


PTD-SE/ 26
Power Transmission and Distribution Service

DIGSI 4 - Generate Copies/Variants

A selected relay can be copied:


„Edit > Copy“ und „Edit > Paste“
The new relay comes up
Note: The new relay has a new internal address. Original and
copy are different.

For a selected relay a variant can be generated:


„Edit > Create variant“
The new relay variant comes up.
Note: The variant has the same address like the original relay.
Original and variant are not different!

Project Administration 02.1_A0


PTD-SE/ 27
Power Transmission and Distribution Service

DIGSI 4 - Copie versus variant

A relay must be copied, when there are two ore more


relays of the same type and the parameters should be
copied.
In this case the new relay must be initialized first (to
get a new internal address).
For a relay a variant must be created, when there are
multiple parameter settings are required for one relay.
The relay has to be initialized only once, because the
variants have all the same address.

Project Administration 02.1_A0


PTD-SE/ 28
Power Transmission and Distribution Service

DIGSI 4 - Device variants - Import and Export

Original: scheduled set


from the Project Department Expor
t

Version: IBS set


from the Commissioning Department

Import

Version: operator set


from the Operations Department

Project Administration 02.1_A0


PTD-SE/ 29
Power Transmission and Distribution Service

DIGSI 4 - Device variants

A device variant is generated as follows

Generate a variant of an exisiting


SIPROTEC 4 device

Import device data

Plug & Play connection to a


SIPROTEC 4 device

Project Administration 02.1_A0


PTD-SE/ 30
Power Transmission and Distribution Service

DIGSI 4 - Export Device Data

Open dialog box


Define destination
Start exporting procedure

Project Administration 02.1_A0


PTD-SE/ 31
Power Transmission and Distribution Service

DIGSI 4 - Importing Device Data

Import device data as SIPROTEC 4 variant

Open dialog box


Select Import File
Start the import procedure

Project Administration 02.1_A0


PTD-SE/ 32
Power Transmission and Distribution Service

DIGSI 4 - Importing of Device Data

Import device data as SIPROTEC 4 device

Open dialog box


Select Import File
Start importing procedure

Project Administration 02.1_A0


PTD-SE/ 33
Power Transmission and Distribution Service

DIGSI 4 - Working with variants

Create a new variant of your relay (in „Region North“): „My


relay 1“. Change one parameter.
Export the variant into the file system („Myrelay1.dex“ on
„C:\Floppy“).
Import the export file as a SIPROTEC 4 variant: „My relay
2“.
Change the parameterization of the original relay.
Import the export file directly as SIPROTEC 4 relay and
replace the original relay.

Project Administration 02.1_A0


PTD-SE/ 34