Sie sind auf Seite 1von 13

BUTWAL POWER COMPANY

LIMITED (BPC)OFFICE BUILDING


Location:- Buddhanagar, Kathmandu
Building type:- office
Architect:-Innovative CREATEERS Pvt.Ltd.
Completed date:- 2017
Area:-
Plinth area:-571 sq.m.
Total floor area:-5668.61 sq.m.
Why is bpc a sustainable building?
• Energy efficient
• water efficient
• environment friendly material used
throughtout the building.
• Roof garden is present in the building which
acts as the heat insulation layer
• Double Glazed Windows to prevent heat loss
from the building.
ENERGY EFFICIENCY
• World class energy efficient practices have been used in the
building
• Treated air from Earth Air Tunnel (EAT) which is used as
pre-heated air to Solar Air Heating (SAH) Panels, rather
than directly supplying to office rooms as it is used to in
other countries.
• Major portion of terrace roof is covered with roof garden,
which acts like and heat insulation layer and will contribute to
reduce heat island effect.
• Major energy saving measure adopted in HVAC system are
energy efficient Variable Frequency type air-conditioning
system and air handling units with Energy Recovery Ventilator.
• the SAH panels has been modified
considering high dust particle content in
Kathmandu air. An array of SAH panels (60
numbers) are installed producing 30 kilowatt
of hot air supply into the building
• Hybrid of Solar Electricity Generation System
(4 kilowatts) and Wind Turbine (2 kilowatts)
has been designed for charging electric
vehicles, lighting common area (basement,
staircase, corridor & toilet) and security
system
WATER EFFICIENCY
Rainwater Harvesting System
Sewerage Treatment Plant
Waste & Resource Management

• Sewerage Treatment Plant for grey water


treatment (cistern with grey water tank
• Gray-water produced from this system is used
for irrigation of plants and washing vehicles
• Rainwater Harvesting System of capacity of
70,000 liters is installed and overflow from the
underground water tank is connected to the
Underground Water Charging System.
INDOOR ENVIRONMENTAL QUALITY

• Adhesives, paints, carpets and sealable with


VOC are not used in the Project in order to
prevent contamination of indoor air during
operation of the building
• In order to improve Indoor Air Quality of the
building; Treated Fresh Air System (TFAS) is
incorporated in HVAC system.
solar panels
roof garden
INTERIOR
INTERIOR
REFERENCE
• http://createers.com.np/bpc.html