Sie sind auf Seite 1von 12

Opcenter Connect MOM 3.

3
Release Preview
2020 12 09

Restricted © Siemens AG 2020 Realize innovation.

Restricted
. Drag picture to placeholder or click icon to add
Agenda
Release Overview

Demo

Problem Report Resolution

Q&A

Restricted
Restricted©©Siemens
SiemensAG
AG2017
2020
Page 2 20YY.MM.DD Siemens PLM Software
Release Overview
Opcenter Connect MOM
Release Overview 3.3

Security Enhancements

Diagnostics Service Enhancements

OPC UA Adapter Enhancements

Restricted © Siemens AG 2017


Page 4 20YY.MM.DD Siemens PLM Software
Opcenter Connect MOM
Release Overview 3.3

Security Enhancements

Opcenter Connect MOM release 3.3 includes following security enhancements:

• Secure logging services: Implemented OWIN (Authentication Framework) for services,


Logging service, CAH service.

• License validation removed from configuration services and moved to CAH/Broker service

• Introduced new security policies in OPC UA adapter: Basic256, Basic256SHA256 etc.

- Restriction: MIO web directory could be browsed, exposing ServiceConfiguration.json

Restricted © Siemens AG 2017


Page 5 20YY.MM.DD Siemens PLM Software
Opcenter Connect MOM
Release Overview 3.3

Diagnostics Service Enhancements

• “System Health” tab: Column “Total CPU Usage” added

• “Log History” page added: Records log messages

• Filter options added: Filter messages based on Message ID, Type, Category, Channel Adapter, Time
duration, Date range, Log text and Content text.

• Additional Option: Show Content

• Show message in separate window

Restricted © Siemens AG 2017


Page 6 20YY.MM.DD Siemens PLM Software
Opcenter Connect MOM
Release Overview 3.3

Diagnostics Service Enhancements

Restricted © Siemens AG 2017


Page 7 20YY.MM.DD Siemens PLM Software
Opcenter Connect MOM
Release Overview 3.3

Diagnostics Service Enhancements

Restricted © Siemens AG 2017


Page 8 20YY.MM.DD Siemens PLM Software
Opcenter Connect MOM
Release Overview 3.3

OPC UA Adapter Enhancements

• Adapter configurability at runtime

• Discovery Controller added to configuration service

• Culture support: Date and time according to culture setting

Restricted © Siemens AG 2017


Page 9 20YY.MM.DD Siemens PLM Software
Problem Report Resolution
Opcenter Connect MOM
Problem Report Resolution

ID PR Title

129624 PR9659604 SHS ME: MIO 2.3: Error message type for action save object

130823 PR9916570 MIO Connection is active doesn't work

131587 PR9931451 Database Adapters sharing same connection string even pointed to different databases

136012 PR9922785 HA issue: async outbound message via CG very slow when one CN MOM server goes do

136013 PR9916381 HA test reliability. Message is not sent to remaining available broker.

136409 PR9916664 DB Adapter additional configuration username password

137349 PR9924784 Login Failure Connection Error

137350 PR9938155 Sync call from CG in HA not working in 3.2.129.33

137351 PR9917761 Web API adapter round robin didn't work

Restricted © Siemens AG 2017


Page 11 20YY.MM.DD Siemens PLM Software
Questions

Das könnte Ihnen auch gefallen