Sie sind auf Seite 1von 7

Thermodynamics without entropy

or analogies among dynamical systems


• please note the distinction between Static and Dynamic energy storages
• small w denotes total energy, capital W denotes energy density
• systems can be “lumped parameter” or distributed
• Four variable models -- note the “oddball” down in the lower left corner
• yes, Virginia, dynamic is really different from static energy storage (you always
knew there was something strange about kinetic energy and momentum)
• Primary network variables are the ones whose product is power (or power flux)
and whose ratio is impedance -- the use of any other variable pair as the primary
variables impedes building complicated systems from elementary building blocks;
although it can, at times, be thermodynamically advantageous
• The impedance is what will damp out vibration, lower “Q”, and stabilize
systems

Copyright 2001 Kevin G. Rhoads


CC BY Licensed
v q voltage charge Push stuff

 i flux-turns linkage current Thud Flow

Impedance = v / i C

v q wstatic = v dq
ddt ddt

wdynamic = i d  i
Power = v i
L
Uncertainty Pair

Electrical Lumped
Element

Copyright 2001 Kevin G. Rhoads


CC BY Licensed
F x Force position Push stuff

p v momentum velocity Thud Flow

Mechanical Impedance = F / v 1/k

F x wstatic = F • dx
ddt ddt

wdynamic = v • dp p v
Power = F v
m
Uncertainty Pair

Linear Lumped
Mechanical Element
Variables (i.e., F, x, v, p) may be scalars or vectors.

Copyright 2001 Kevin G. Rhoads


CC BY Licensed
T  Torque position Push stuff
(angular)
L  momentum velocity Thud Flow

Mechanical Impedance = T /  1/k

T  wstatic = Td
ddt ddt

wdynamic =  dL L 
Power = T 
I0
Uncertainty Pair

Rotational Lumped
Element
Mechanical

Copyright 2001 Kevin G. Rhoads


CC BY Licensed
Electric field Displacement Push stuff
E D Intensity Flux Density
Magnetic Flux Magnetic
B H Density Field intensity Thud Flow

Wave Impedance = |E| / |H| 0

E D Wstatic = E • dD
t, t,
 
Wdynamic = H • dB B* H
Power Flux Density = E  H
0
Uncertainty Pair, in
some extended sense
Electrical Distributed
* Fields
instead of B one could use A, this does break the
System
symmetry of the analogy and is not recommended

Copyright 2001 Kevin G. Rhoads


CC BY Licensed
Pressure Volume
P Q [V] Differential
Push stuff

Momentum Volume rate


p Q´ Density of flow Thud Flow

Flow Impedance = P / Q´ Gas Law

P Q Wstatic = P dQ
t t

Wdynamic = Q´ dp p Q´
 Power Flux Density = P Q´

Gas Flow Distributed


System
Fluid Flow

Copyright 2001 Kevin G. Rhoads


CC BY Licensed
P  Pressure variations displacement Push stuff
(Intensity)

p v momentum Thud Flow


density velocity

Acoustic Impedance = P / v 1/M*

P  Wstatic = P d
t t

Wdynamic = v dp p v
Power Flux = P v

? Uncertainty Pair, in
some extended sense

Acoustic Distributed
*
M is bulk modulus; for isothermal it is (for small strains) equal to the unperturbed pressure System
for sound, however, adiabatic is more accurate than isothermal, so multiply by 1.4 for diatomic gases

Copyright 2001 Kevin G. Rhoads


CC BY Licensed

Das könnte Ihnen auch gefallen