Sie sind auf Seite 1von 27

The Universal Platform Acquisition Workstation ---

OmniVision
2009.Jun.10th

Introduction
MMI MMI
Function Explanation

Daily Workflow
Image Post Processing -- ANALYTICA

1. Function Explanation
There are three ways to start the exam:

MMI

Query patient from DICOM Worklist server and start exam Add patient scheduled exam in Local Worklist and start exam

Emergency
Click button and immediately start exam without insert any patient information and Scheduled Procedure.

MMI

1. Function Explanation
Function of Acquisition Acquisition GUI

MMI

MMI

Image Preview Area

2
3

1. Function Explanation
Acquisition GUI Functional Tool Generator interface

MMI

X-ray Technique console Switch ms/mAs Grid On/Off Patient Body Size AEC Function

MMI

Dual Detector Selection

OmniVision could support the Generator Virtual Console for Full System Integration and Retrofit System Integration.
Current we could support Generator from vendor below : - COMED, CPI, EMD, SEDECAL, TOSHIBA - DEL MEDICAL --- *Work In Progress

1. Function Explanation
Acquisition GUI Functional ToolImage Manipulation

MMI

Image Manipulation

Image Histogram Display

MMI

Once image finish Post-Processing, user could apply image manipulation on the image. Acquired Image Histogram will display as a reference.

1. Function Explanation
Acquisition GUI Functional ToolImage Manipulation
Counterclockwise rotation Window Level Adjustment
(Right-click could W/L adjustment)

MMI

Clockwise rotation

Apply W/L with selected ROI

Vertical Flip

Insert Digital Marker

MMI

Image Preview Area


Horizontal Flip Crop Image

Invert

Set Preferred W/L

Annotation (Turn On/Off)

Apply Preferred W/L

1. Function Explanation
Acquisition GUI Functional ToolStudy Information

MMI

Patient Information

Image Information

MMI

Image Preview Area

Detail Patient Information will be shown in this [Information] tab page. While switching the different projection series, the image information will be updated.

1. Function Explanation
Acquisition GUI Functional ToolPost Processing

MMI

Five Post Processing Parameters

Auto-Masking (Collimator Detection)

MMI

Apply post processing parameters For Admin level and Engineer level, image could be re-processing if not s atisfy with the result. This function will be available for all level user in D emo version. Detail explanation about the Post Processing parameter, please refer to Section 3.

1. Function Explanation
Acquisition GUI Procedure View

MMI

Scheduled Procedure View(s)

MMI

Previous / Next

User could choose the view that they wish to process accordingly.
After acquired the x-ray image, the thumbnail box will update with the processed x-ray image.

1. Function Explanation
Acquisition GUI Exam Management
Acquisition Mode Demo Mode Simulate Hand Switch Ready Step. Simulate Hand Switch Exposure Step.

MMI

Add New View/Projection

MMI

Reject Acquired Images (If Rejected Analysis has been enable, while click this button, operator will need to fill up a reason to reject image.) End Exam to Close Study

Image Preview Area

1. Function Explanation
Review GUI Function ToolImage Layout

MMI

MMI

Image Preview Area

Double-click on selected study, user could review all the images.

1. Function Explanation
Review GUI Function ToolImage Layout

MMI

MMI

Image Preview Area


2 3

Double-click on selected study, user could review all the images.

1. Function Explanation
Review GUI Functional Tool Image Layout

MMI

1x1 display layout

1x2 display layout

MMI

Image Preview Area


2x1 display layout

2x2 display layout

1. Function Explanation
Review GUI Functional ToolManipulation & Measurement

MMI

Manipulation & Measureme nt Tool

Image Histogram Display

MMI

Image Preview Area

User could use various Image manipulation tool to review the images.
For Example, for Orthopeadics doctor, they could apply go to [Measurement] page to use button, then

to measure the fractured joint

distance.

1. Function Explanation
Review GUI Functional ToolPost Processing

MMI

Zoom In

Magnify Glass

Zoom Out

Regional Enhancement

True Size

Angle Measurement

MMI

Fit to Screen

Length Measurement

Pan Image

1. Function Explanation
Review GUI Functional Tool Magnify Glass & Regional Enhancement

MMI

Magnify Glass Function

MMI

Image Preview Area

Regional Enhancement Function

1. Function Explanation
Review GUI Series image

MMI

Series Image

MMI

Image Preview Area


Previous / Next Select the Series Image that wish to review. The Image will shown on the Image Review Area. Click Left Arrow and Right Arrow to move to Previous or Next Series.

1. Function Explanation
Review GUI Exit Review Mode

MMI MMI
Click [Close Study] to exit the Image Review Mode and return to Study Management GUI. Image Preview Area

1. Function Explanation
Review GUI Study Management

MMI

MMI

Locked Study will protected from Delete action.

Check Sent & Print Status o f each image

Manual Send Studies to PACS

Manual Delete Studies

1. Function Explanation
Configuration GUI DICOM Connectivity
DICOM Connectivity

MMI

DICOM Storage (PACS Server)

MMI

DICOM Print

DICOM Worklist Server

1. Function Explanation
Configuration GUI APR Parameter Setting

MMI

MMI

1. Function Explanation
---

Configuration GUI APR Parameter Setting


4 - Steps Code Mapping ---

MMI

MMI

STEP 2 : Confirm all the CPT code has been imported and displayed in this section.

STEP 3 : Create Procedure as similar with Code Meaning as possible. Then, define each procedures view.

STEP 1 : Import Hospital Procedure Code (CPT Code) in .xls format

STEP 4 : Click Auto Match to apply auto-mapping. Completed.

1. Function Explanation
Configuration GUI Reject Analysis Setting

MMI

MMI

2. Daily Workflow
MMI MMI

3. Image Processing -- ANALYTICA


BY ANALYZING THE DATA FIRST

MMI

ANALYTICA CAN PROVIDE


Better Visibility and Contrast of Better Depiction of Better Delineation of .. Simultaneous Viewing of ..

Small and Weak Structures Overlapping Structures Bone Structures Bone and Soft Tissue

MMI

Reduced Window Width & Window Leveling More Robust Dataset Handling

3. Image Processing -- ANALYTICA


MMI
P1 (Parameter 1)

: Weighting of structures with a size around 2 pixels. - Tuning level of detail features. - Value ,detail is clearer and edge is sharper. : Weighting of structures with a size around 4 pixels. - Tuning the sharpness of high-density features. - Value , larger structures will be show more detail. : Weighting of structures with size larger than 4 pixels. - Applied to get a proper image contrast and sharpness. - Value , image shows more detail but will be smoothed. : Gamma curve mapping of the image. - Adjusted to provide suitable contrast of whole image. - Value , image looks more contrast and darker overall. : Enable will apply Chest Preference LUT Processing; Disable will not apply Chest Preference LUT Processing.

MMI

P2 (Parameter 2)

P3 (Parameter 3)

P4 (Parameter 4)

P5 (Parameter 5)

Das könnte Ihnen auch gefallen