Design Mix-A
CEMENT IN KG / M3 ..................... 470 Percentage Dosage % V.ZEMENTGEWICHT................. 6.00 28
Cement Content IN KG.................................................... 470
DICHTE D. ZUSATZMITTELS........ 1.43 Concrete Cylinder Filling rate 90%
Stroke /MIN 6.00 8.00 10.00 12.00 14.00 16.00 18.00
M3/ hr 4.01 5.34 6.68 8.02 9.35 10.69 12.02

3% ZUSATZMTL=L/MIN 0.66 0.88 1.10 1.32 1.54 1.76 1.98


4% 0.88 1.17 1.46 1.76 2.05 2.34 2.63
5% 1.10 1.46 1.83 2.20 2.56 2.93 3.29
6% 1.32 1.76 2.20 2.63 3.07 3.51 3.95
7% 1.54 2.05 2.56 3.07 3.59 4.10 4.61
8% 1.76 2.34 2.93 3.51 4.10 4.68 5.27
9% 1.98 2.63 3.29 3.95 4.61 5.27 5.93
10% 2.20 2.93 3.66 4.39 5.12 5.85 6.59

Stroke /MIN 20.00 22.00 24.00 26.00 28.00 30.00


M3/ hr 19.01 20.91 22.81 24.71 26.61 28.51

3% ZUSATZMTL= L/MIN 3.12 3.44 3.75 4.06 4.37 4.69


4% 4.16 4.58 5.00 5.41 5.83 6.25
5% 5.21 5.73 6.25 6.77 7.29 7.81
6% 6.25 6.87 7.50 8.12 8.75 9.37
7% 7.29 8.02 8.75 9.48 10.20 10.93
8% 8.33 9.16 10.00 10.83 11.66 12.49
9% 9.37 10.31 11.25 12.18 13.12 14.06
10% 10.41 11.45 12.49 13.54 14.58 15.62

REGULIERUNG DER ZUSATZMITTELPUMPE IN KOMBINATION MIT PUTZMEISTER BSA 1002

INDURESA PUTZMEISTER PME C:\EXCEL\PME-MEZC\ZMDTFW.XLS