YSHIELD

EMR - PROTECTION

Shielding of electromagnetic fields


YSHIELD® YSHIELD GmbH & Co. KG | Germany
0049-(0)8531-41079-0 | www.yshield.com
1 12.08.2021
8/12/2021

Technisches Merkblatt - Abschirmbeschichtungen


Technical data sheet - Shielding coatings

HSF54 PRO54 MAX54 HSF64 NSF34


Produktart Farbe Farbe Farbe Farbe Farbe
Product type Paint Paint Paint Paint Paint
Lieferform Flüssig Flüssig Flüssig Flüssig Flüssig
Delivery form Liquid Liquid Liquid Liquid Liquid
Einsatzbereich Innen, Aussen Innen, Aussen Innen, Aussen Innen Innen, Aussen
Scope of application Interior, Exterior Interior, Exterior Interior, Exterior Interior Interior, Exterior
Ergiebigkeit p. Lage
4 – 8 m²/l 4 – 8 m²/l 4 – 8 m²/l 4 – 8 m²/l 8 – 10 m²/l
Coverage p. layer
Untergründe Fast alle Fast alle Fast alle Saugfähig Fast alle
Substrates Almost all Almost all Almost all All absorbent Almost all
Schirmungsart HF + NF HF + NF HF + NF HF + NF Nur NF
Shielding type HF + LF HF + LF HF + LF HF + LF Only LF
Schirmung | Shielding 1-lagig | 1-layer 1-lagig | 1-layer 1-lagig | 1-layer 1-lagig | 1-layer 1-lagig | 1-layer
1 - 40 GHz (4 m²/l) 44 dB - 54 dB 43 dB - 62 dB 49 dB - 72 dB 43 dB - 52 dB 80 dB = 99.99 %
Schirmung | Shielding 2-lagig | 2-layer 2-lagig | 2-layer 2-lagig | 2-layer 2-lagig | 2-layer
1 - 40 GHz (4 m²/l) 53 dB - 72 dB 49 dB - 78 dB 57 dB - 87 dB 50 dB - 75 dB
Schirmung | Shielding 3-lagig | 3-layer 3-lagig | 3-layer 3-lagig | 3-layer 3-lagig | 3-layer
1 - 40 GHz (4 m²/l) 60 dB - 90 dB 55 dB - 94 dB 64 dB - 100 dB 54 dB - 93 dB
Ökologie Hoch Hoch Hoch Sehr hoch Hoch
Ecology High High High Very high High
Bindemittel Reinacrylat Reinacrylat Reinacrylat Wasserglas, Reinacrylat
Binding agent Pure acrylate Pure acrylate Pure acrylate Acrylat | Silicate, Pure acrylate
acrylate
VOC-Gehalt
0.18 g/l 0.19 g/l 0.19 g/l 0.17 g/l 0.20 g/l
VOC content
Konservierung 64 ppm BIT 58 ppm BIT 64 ppm BIT Keine 69 ppm BIT
Preservation 34 ppm INN 15 ppm INN 34 ppm INN Konservierung | 9 ppm INN
3 ppm MIT 2 ppm MIT 3 ppm MIT No preservation 2 ppm MIT
Zertifizierung
TÜV-SÜD TÜV-SÜD TÜV-SÜD TÜV-SÜD TÜV-SÜD
Certifications
Brandverhalten DIN EN
Fire behaviour 13501-1
Farbe Schwarz Schwarz Schwarz Schwarz Schwarz
Color Black Black Black Black Black
Haftzugfestigkeit
7.6 N/mm² 12.1 N/mm² 4.9 N/mm² 2.3 N/mm² 12.6 N/mm²
Adhesive strength
Viskosität Brookfield
1400 mPas 1800 mPas 1400 mPas 2000 mPas ~ 1200 mPas
Viscosity Brookfield
Sd-Wert
≈ 0.1 m ≈ 0.1 m ≈ 0.1 m ≈ 0.05 m ≈ 0.1 m
Sd-value
PH-Wert
8 8 8 11.6 8
pH value
Dichte
1.26 kg/l 1.16 kg/l 1.25 kg/l 1.26 kg/l 1.06 kg/l
Density
Frostbeständigkeit 5 Zyklen 5 Zyklen 5 Zyklen 5 Zyklen 5 Zyklen
Frost resistance 5 cycles 5 cycles 5 cycles 5 cycles 5 cycles
Lagerstabilität 12 Monate 12 Monate 12 Monate 12 Monate 12 Monate
Shelf life 12 months 12 months 12 months 12 months 12 months
YSHIELD® YSHIELD GmbH & Co. KG | Germany
0049-(0)8531-41079-0 | www.yshield.com
2 12.08.2021
8/12/2021

DRY54 DRY69
Produktart Farbe Spachtel
Product type Paint Putty
Lieferform Pulver Pulver
Delivery form Powder Powder
Einsatzbereich Innen, Aussen Innen
Scope of application Interior, Exterior Interior
Ergiebigkeit p. Lage
4 – 8 m²/l 0.33 - 1 m²/kg
Coverage p. layer
Untergründe Fast alle Saugfähig
Substrates Almost all All absorbent
Schirmungsart HF + NF HF + NF
Shielding type HF + LF HF + LF
Schirmung | Shielding 1-lagig | 1-layer 1 mm | 0.039 inch
36 dB – 42 dB

Schirmung | Shielding 2-lagig | 2-layer 2 mm | 0.079 inch


41 dB - 54 dB

Schirmung | Shielding 3-lagig | 3-layer 3 mm | 0.118 inch


46 dB - 84 dB

Ökologie Sehr hoch Sehr hoch


Ecology Very high Very high
Bindemittel Reinacrylat Wasserglas,
Binding agent Pure acrylate Acrylat | Silicate,
acrylate
VOC-Gehalt
0.12 g/l 0.12 g/l
VOC content
Konservierung Keine Keine
Preservation Konservierung | Konservierung |
No preservation No preservation
Zertifizierung
TÜV-SÜD TÜV-SÜD
Certifications
Brandverhalten
Fire behaviour
Farbe Schwarz Schwarz
Color Black Black
Haftzugfestigkeit
4.1 N/mm²
Adhesive strength
Viskosität Brookfield
1000 mPas
Viscosity Brookfield
Sd-Wert
≈ 0.1 m
Sd-value
PH-Wert
8
pH value
Dichte
1.10 kg/l
Density
Frostbeständigkeit Dauerhaft Dauerhaft
Frost resistance permanent permanent
Lagerstabilität 60 Monate 60 Monate
Shelf life 60 months 60 months
YSHIELD® YSHIELD GmbH & Co. KG, Rotthofer Straße 1, 94099 Ruhstorf, Deutschland
Fon: 0049-(0)8531-31713-0, Email: info@yshield.com, Web: www.yshield.com

Product features behaviour and economical use of preserving agents


is subject to monitoring.
Intended use
Electro-conductive base coatings to shield high-fre-
quency electromagnetic fields and/or low-frequency
electric fields. Low-frequency magnetic fields are not
shielded.
Area of application
Walls and ceilings: Unlimited possible. You will find
the suitability for interior or exterior application in the
table on the first page.
Floor areas: ● Loose or floating floor coverings
(carpets, laminate, etc.) can be laid directly onto the Safe material handling
shielding paints. Pay attention, that the shielding paints
Safety notes
are not damaged! ● In case of glued floor coverings
(carpets, cork, laminate, etc.) the shielding paints have All paints have a high coloring capability, so please
to be aftertreated with our primer GK5 to improve the proceed with care. Wipe off stains immediately with
adhesion. ● We advise against bonding e.g. real-wood damp cloth. Do not let stains dry up. Do not inhale
parquets. spray mist! Absolutely make sure, that all areas are well
ventilated during use and drying time. Do not eat, drink
Under plaster: Due to high adhesive tensile strenghts
or smoke during painting! Rinse thoroughly immedia-
applicable directly under pure organic plasters.
tely after skin or eye contact!
Corrosion resistance
VOC-content
All shielding paints don´t contain metal particles.
Please refer to the table on the first page. The EU
Based on carbons they are long-term durable and not
limit value for cat. A/a is 30g/l (by 2010).
oxidizing.
Ingredients
Ready for 5G
HSF54: Water, natural graphite, pure acrylics dispersion,
Our shielding paints have an almost linear screening
carbon black, additives, preservative (BIT, INN, MIT).
attenuation for a very large frequency range including
both 5G frequency spectrums FR1 (600 MHz - 6 GHz) HSF64: Water, potassium silicate, natural graphite,
and FR2 (24 GHz - 40 GHz). carbon black, pure acrylics dispersion, additives, NO
preservation agent.
Safety up to 40 GHz
MAX54: Water, natural graphite, pure acrylics disper-
We have a professional EMC-laboratory according to sion, carbon black, additives, preservative (BIT, INN, MIT).
various standards up to 40 GHz on site. You’ll find the
measuring curves and reports from 40/600 MHz - 40 GHz PRO54: Water, pure acrylics dispersion, carbon fibers,
in the internet on the corresponding product pages. natural graphite, carbon black, additives, preservative
(BIT, INN, MIT).
No nanotechnology
TEC54: Water, natural graphite, pure acrylics dispersion,
Our shielding paints are developed in accordance carbon black, additives, preservative (BIT, INN, MIT).
with strict ecological criteria. We use the carbon black
NSF34: Water, pure acrylics dispersion, carbon black,
with the lowest emission possible on the market and
natural graphite, additives, preservative (BIT, INN, MIT).
untreated natural graphite. We consciously do not use
graphene, a nanomaterial where the hazard potential is Preservative
still completely unknown. If stated above, the shielding paint contains BIT
TÜV-SÜD certification (1,2-Benzisothiazolin-3-on), INN (Zink-Pyrithion) and MIT
(2-Methyl-4-isothiazolin-3-on) for preservation. Zink-
We have our shielding paints HSF54, HSF64, PRO54
Pyrithion (INN) is a safe replacement for MIT, that is by
and NSF34 monitored by TÜV-Süd. The produc-
legislature subject to labeling from 2020 over 15 ppm.
tion process including quality control, emission
Advisory service for allergic persons under telephone
number 0049-(0)8531-31713-0.
YSHIELD® YSHIELD GmbH & Co. KG, Rotthofer Straße 1, 94099 Ruhstorf, Deutschland
Fon: 0049-(0)8531-31713-0, Email: info@yshield.com, Web: www.yshield.com

Grounding Application temperature


Grounding regulation Minimum application temperature: 5°C / 41°F. This
temperature also counts for the drying time!
Large area shieldings executed with shielding mate-
rials are no electrical equipment but „new conductive Underground
parts“ according to IEV 826-03-03 or IEV 195-06-11 and HSF54, MAX54, PRO54, TEC54, NSF34: Excellent
thereby a new method of DIN VDE 0100-100:2009-06. adhesion on almost all undergrounds like emulsion
By connecting the material(s) to the potential equaliza- paints, dry construction boards, wallpaper, cement,
tion they are an inherent part of the electrical system. plaster, masonry, wood, many plastics, etc.
Generally accepted rules of technology have to be
HSF64: Good adhesion on all absorbent undergrounds.
respected.
Important: With potassium silicate as ingredient not
According to the latest state of technology it is applicable on gypsum based undergrounds.
important to distinguish between protective equi-
Common: The underground needs to be solid, clean,
potential bonding and functional equipotential
degreased and dry. Absorbent or porous surfaces must
bonding (FEB). The protective equipotential bonding
be prepared with a primer. Old coats of paint or old
(green/yellow cable) is a protective measure and
wallpapers which can be etched with water, should be
ensures, in the event of contact voltage, the imme-
removed.
diate action of safety devices (e.g. line safety switch).
The function of the functional equipotential bonding Priming coat
(transparent cable)is the reduction of emission of low Absorbent or porous surfaces necessarily must be
frequency electrical fields on large area shieldings (i.e. prepared with our primer GK5. In case of not using a
prevention of leaking electrical field). primer, the binding agent will infiltrate together with
Grounding accessories the water in the substrate. In addition, this will lead to
an aggravation of the physical characteristics of the
To obtain an accurate grounding, we exclusively
shielding paints. Optical control: Paint a small test
recommend our grounding accessories. For interior
area and let dry. When the surface is silver shimmering,
use: Grounding plate GW or GB in combination with
the underground is too absorbent. When the surface is
grounding strap EB2. For exterior use: Grounding plate
pure black, the underground is adequately primed.
GE. Please find more information in our “Technical
data sheet - Grounding”. Preparation
The conductive particles deposit on the bottom of the
Processing paint container. Shake the paint container well and
Interior approach mix it thoroughly after opening with an electrical
● Prepare the underground with our primer GK5. ● Drill paint stirrer for at least one minute. For our 1-liter
holes for the grounding plate. ● The grounding strap bins please use our stirrer AR42.
has to be applied uninterrupted in one piece through Compatibility
all surfaces to be painted, as stated in our grounding All shielding paints are ready for use. Never mix with
instructions sheet. ● Apply the shielding paint in one or water or other coating materials.
two layers, depending on the favored shielding attenu-
ation. Apply second coat of shielding paint to the area Application
where the grounding plate will be mounted. ● Allow ● Use a first-class paint roller with a pile height of
the paint 24 hours to dry. ● Fix the grounding plate. 10-13 mm. To achieve a constant high attenuation, it is
● For further procedure references please follow up at essential to apply the shielding paint with equal thick-
subitem „Final coat“. ness, do not skip areas! Always soak the paint roller with
Exterior approach the equal amount of paint and try to coat equal large
surfaces with this amount! ● Limited usable are lacquer-
● Prepare the underground with our primer GK5. rollers, foam-rollers or brushes, as the coating often
● Level out the mounting surface for the grounding gets applied too thin for a good attenuation! ● Airless
plate. ● Drill holes for the grounding plate. ● Apply spraying is possible, please find the minimum hole sizes
the shielding paint in one or two layers, depending on in the table on the first page. ● Application methods in
the favored shielding attenuation. Apply second coat technical coatings: Knife coating, dip-coating, roll appli-
of shielding paint to the area where the grounding cation, etc.
plate will be mounted. ● Allow the paint 24 hours to
dry. ● Fix the grounding plate and glue the top cover.
● For further procedure references please follow up at
subitem „Final coat“.
YSHIELD® YSHIELD GmbH & Co. KG, Rotthofer Straße 1, 94099 Ruhstorf, Deutschland
Fon: 0049-(0)8531-31713-0, Email: info@yshield.com, Web: www.yshield.com

Drying time Further information


● Allow to dry for 24-48 hours before overcoating. Storage
● Protect from rain at least for 24 hours. ● The coating is
Store cool and frost free. Keep safe from children. Once
entirely cured after 7 days.
the paint container has been opened, close tightly after
Final coat usage and store cool.
To protect the soft, viscoplastic surfaces of the shielding Period of storage
paints against mechanical damage and humidity, we
At least 12 months, see the batch sticker on the paint
recommend to apply 2 top coats. Worldwide variably
container.
paints are available, therefore we never can give a guar-
antee for specific combinations. In addition many pure Disposal
mineral paints and ecologic paints often adhere bad on Utensils have to be cleaned immediately after use
the graphite surface of the shielding paints. We always with water and soap. Containers must be absolutely
recommend to apply a paint coat on a test area empty for recycling. Dried up paint remainders may
before processing. be disposed of with the household garbage. Do not let
Interior: With high-quality, good covering, plastic remains escape into sewerage, water bodies or ground.
bonded dispersion emulsion paints or dispersion sili- Identification marks
cate paints. Alternatively paste over with wallpapers,
glass fabrics, etc. Produktcode: M-DF01 (GISCODE)
Water hazard class: 1 (VwVwS)
Exterior: With high-quality, good covering, highly Waste code: 08 01 12 (AVV)
hydrophobic dispersion emulsion paints or silicon resin Hazardous ingredients: −
paints. ADR: −
Under plaster (MAX54, HSF54, PRO54, NSF34): UN-number: −
Due to the high adhesive tensile strenghts of the Transport hazard class: −
shielding paints, these are applicable (in conformity Environmental dangers: −
with ETAG 004 for EIFS-systems, minimum 0.08 N/mm²)
Safety data sheet
after prior priming under plastic bonded plaster. Never
use mineral plasters, no adhesion! The safety data sheet is available upon request under
telephone number 0049-(0)8531-31713-0.
Consumption
Disclaimer
The consumption depends on the character and absor-
bency of the underground. Typical coverage Preceding information has been assorted to the latest
5 - 7.5 m²/l. Referring to customer feedbacks we know, state of processing and application technology. As we
that our shielding paints are often applied to thin. For a dont have any influence on processing and applica-
good levelling, our paints are of low viscosity and that´s tion, no liabilitay can be accepted out of the contents
why our customers tend to a thin coating. The problem of this information sheet. Processors are in either case
is, that a coverage of more than 7.5 m²/l leads to a bounded to a skilled evaluation of the processing, in
decrease in attenuation! We advise to paint always consideration of the product attributes and fitness.
quite thick. Details and notwithstanding details, transcending the
content of this information sheet, require our confir-
mation in writing. Our general terms and conditons
are valid as mentioned. With this newest edition of our
technical data sheet all previous versions loose their
validity.
YSHIELD® HSF54 | Standard shielding paint | 1 liter
Standard paint with the best all-round properties – one paint suitable for everything. Up to 90 dB at 40 GHz. TÜV-SÜD
certified.

As shielding paint for rooms and buildings


Shielding paint for shielding high-frequency radiation (HF) and low-frequency electric fields
(LF). Breathable, solvent-free, plasticizer-free and low-emission.

Standard paint with the best all-round properties – one paint suitable for everything. Up to
90 dB at 40 GHz. TÜV-SÜD certified. Extremely high shielding in all situations. Suitable for
very difficult substrates due to its high adhesive tensile strength. This paint is very finely
pigmented, very easy to process and forms a finely blended hard film. The HSF54 forms the
most even surface out of all our shielding paints.
Screening attenuation
At a yield of 4 sqm/l:
At 1 GHz: Single layer 44 dB | Double layer 53 dB | Three layer 60 dB
At a yield of 8 sqm/l:
At 1 GHz: Single layer 39 dB | Double layer 46 dB | Three layer 51 dB
Underground
Excellent adhesion on almost all substrates interior and exterior.
Top coating
Preferably covered with plastic bonded water-based emulsion paints, dispersion silicate paints, facade
paints or silicon resin paints.
Optional: Fiber additive AF3
For crack bridging and a better grounding we advise our fiber additive AF3 with long conductive carbon
fibers.
Frost resistance
This product is frost resistant (proved for 5 frost-/thaw cycles) and can be shipped throughout the year
by air cargo or ship.
Ingredients
Water, natural graphite, pure acrylics dispersion, carbon black, additives, preservative (BIT, INN, MIT).
Technical data
Please find detailled data in the table overview and the technical data sheet.
No nanotechnology
Our shielding paints are developed in accordance with strict ecological criteria. We use, for example,
the carbon black with the lowest emission possible on the market and untreated natural graphite. We
consciously do not use graphene, a nanomaterial where the hazard potential is still completely
unknown.
TÜV-SÜD certification
We have our shielding paints monitored by TÜV-SÜD. The whole production process including
quality control, emission behaviour and economical use of preserving agents is subject to monitoring.
Please find the certificate above at the downloads.
Grounding
This product with an electrically conductive surface has to be integrated into the functional-
equipotential bonding (FEB). Please find suitable grounding accessories under "Grounding".
Shielding attenuation HF & LF
This product shields high frequency electromagnetic fields (HF). Unless otherwise stated, the
indicated dB-values apply to 1 GHz. Measurement from 600 MHz to 40 GHz according to standards
ASTM D4935-10 or IEEE Std 299-2006.

This product with an electrically conductive surface shields low-frequency alternating electric
fields (LF).
Laboratory & expert report of shielding attenuation up to 40 GHz
We have already invested in our own professional EMV laboratory years ago. We not only use it to
create our laboratory screening reports but also to check each batch daily. Additionally, we have all our
products checked by an independent, well-respected expert. Double checked for twice the safety.
Please find the reports above at the downloads.
Ready for 5G
Some companies offer "special" 5G-products. This products shields all 5G-frequencies, even
without advertising this! Find two gray bars in all shielding diagrams with the 5G frequency
spectrums FR1 (600 MHz – 6GHz) and FR2 (24 GHz – 40 GHz).

YSHIELD GmbH & Co. KG, Rotthofer Straße 1, 94099 Ruhstorf, Germany, www.yshield.com, info@yshield.com, 0049-8531-410790
Please find our laboratory & expert shielding reports, certifications, data sheets, weight, sizes, GTIN, COO, TARIFF, etc. on our website.
YSHIELD® YSHIELD® GmbH & Co. KG, Rotthofer Straße 1, 94099 Ruhstorf, Germany
Fon: 0049-(0)8531-31713-0, Email: info@yshield.com, Web: www.yshield.com

Gutachten Schirmdämpfung Expert report screening attenuation


Messobjekt Measuring object Screening attenuation Shielding paint HSF54
40 MHz 100 MHz 600 MHz 1 GHz
Single layer Double layer Three layer
10 GHz 40 GHz 
Abschirmfarbe HSF54 Shielding paint HSF54
mit Malerwalze with paint roller -10 dB
Datum der Messung Date of measurement
-20 dB
18.12.2019 2019/12/18
Vorbemerkung Preliminary Note -30 dB

Die Prüflinge werden The test samples are



mit einer definierten irradiated with a defined -40 dB

Leistungsflussdichte S1 power flux density S1,


-50 dB 
bestrahlt, die durchdringende the pervasive power flux
Leistungsflussdichte density is measured. The 
-60 dB
S2 wird gemessen. Die shielding attenuation is a
Schirmdämpfung ist eine non-dimensional measured
-70 dB
dimensionslose Messgröße variable in decibels (dB) and
in Dezibel (dB) und wird wie calculated as follows: -80 dB
folgt berechnet:
-90 dB

dB Attenuation
dB Dämpfung 10 90 % -100 dB © YSHIELD GmbH & Co. KG
DVB-T GSM / UMTS
10 90 % 20 99 % LTE
20 99 % 30 99,9 % 5G 5G

30 99,9 % 40 99,99 %
40 99,99 % 50 99,999 % 40 MHz - 40 GHz
50 99,999 % 60 99,9999 %
60 99,9999 % ... ...
... ... Einlagig / Single layer
Conformity 12/18/2019 4:02:31 PM

Konformität
1311.6010K72-101750-NK

The measurement Trc1


00dB
S21 dB Mag 10 dB/ Ref 0 dB Cal Math Smo 1

M1 1.000000 GHz -39.4759 dB

Die Messung der Dämpfung of the attenuation of


-10

-20

elektromagnetischer Wellen electromagnetic waves -30

M1

von 40/600 MHz bis 40 GHz between 40/600 MHz


-40

-50

wurde (wahlweise je nach – 40 GHz (selectively -60

Materialeigenschaften) in depending on the material


-70

-80

Übereinstimmung mit dem properties) has been -90

7E+7 1E+8 2E+8 3E+8 4E+8 5E+8 7E+8 1E+9 2E+9 3E+9 4E+9 5E+9 7E+9 1E+10 2E+10 4E+10

Standard IEEE Std 299™- conducted in accordance


-100

Ch1 Start 40 MHz Pwr 8 dBm Bw 100 Hz Stop 40 GHz

2006 oder in Anlehnung an with standard IEEE Std Zweilagig / Two layer
den Standard ASTM D4935- 299™-2006 or following to Trc1
00dB
12/18/2019 4:04:15 PM
1311.6010K72-101750-NK

S21 dB Mag 10 dB/ Ref 0 dB Cal Math Smo 1

M1 1.000000 GHz -49.6775 dB

10 durchgeführt. standard ASTM D4935-10. -10

-20

Ort der Messung Place of measurement -30

-40

Eigenes EMV-Labor nach In our own EMV laboratory -50


M1

gängigen etablierten according to prevalent -60

-70

Standards, zur täglichen established standards, for -80

Qualitätssicherung und daily quality control and -90

-100
7E+7 1E+8 2E+8 3E+8 4E+8 5E+8 7E+8 1E+9 2E+9 3E+9 4E+9 5E+9 7E+9 1E+10 2E+10 4E+10

Produktentwicklung. product development.


Ch1 Start 40 MHz Pwr 8 dBm Bw 100 Hz Stop 40 GHz

Dreilagig / Three layer


Messaufbau Measurement setup 12/18/2019 4:05:54 PM
1311.6010K72-101750-NK

Trc1 S21 dB Mag 10 dB/ Ref 0 dB Cal Math Smo 1

Als Messgeräte verwenden The measuring devices we


00dB
M1 1.000000 GHz -59.2343 dB

-10

wir zwei vektorielle use are two Vector Network -20

Netzwerkanalysatoren Analysers Rhode & Schwarz


-30

-40

Rohde & Schwarz ZNB20 ZNB20 and ZNB40, with a -50

M1

und ZNB40 mit einer measuring dynamics up to


-60

-70

Messdynamik bis 140 dB. 140 dB. -80

-90

Als Antennen für IEEE Std The antennas we use for -100
7E+7

Ch1 Start 40 MHz


1E+8 2E+8 3E+8 4E+8 5E+8 7E+8 1E+9

Pwr 8 dBm Bw 100 Hz


2E+9 3E+9 4E+9 5E+9 7E+9 1E+10 2E+10 4E+10

Stop 40 GHz

299™-2006 verwenden wir IEEE Std 299™-2006 are


breitbandige Hornantennen. broadband horn antennas.
Als Antennen für ASTM The antennas we use
D4935-10 verwenden wir for ASTM D4935-10 are
breitbandige TEM-Zellen mit broadband TEM cells with
radialer Polarisation. radial polarisation.
YSHIELD® DRY54 | Special shielding paint | Powder for 5 liter
Special paint with a focus on long storage suitability. Delivered in powder form without preservative agents. Up to 84 dB at
40 GHz.

As shielding paint for rooms and buildings


Shielding paint for shielding high-frequency radiation (HF) and low-frequency electric fields
(LF). Breathable, plasticizer-free, low-emission and without a preservation agent.

Special paint with a focus on long storage suitability. Delivered in powder form without
preservative agents. Shields up to 84 dB at 40 GHz. Shielding attenuation is not as good as
with the other paints. Adhesive tensile strength, abrasion resistance and film hardness are
also not as good as with the other paints. But: this paint has less packaging waste, lower
international shipping costs and a phenomenal price-performance ratio. This paint is
coarsely pigmented and low viscous, easy to process and forms an even film.

We first produced a powder paint in 2003, but liquid paints become the established ones. The reason for
this was the low performance of an electric screwdriver which was not sufficient for the ingredients that
needed to be dispersed – in our production we need more than 100,000 Watt for a professional
result. After a longer development time we have now found the perfect formula for powdered
shielding paints.

Special characteristics DRY54:

This powder shielding paint stays nearly as liquid as water while mixing – the dust formation
is extremely limited, as the powder blends immediately with the water. The paint becomes thicker
after 15 minutes resting time – it can be perfectly painted with afterwards and you will get a nice
flow for an even shielding.
The phenomenal price-performance-ratio is achieved, as the DRY54 only costs half as much as
our liquid paints. That is why you can paint two times for the same costs.
The powder gets bagged and then vacuum-packed three times. Vacuum-packed into one
another, using three bags – that is why no moisture will get into the powder, even years later.
The powder needs to be mixed with water - what you will need to do so: Digital scales, protective
mask, safety glasses, our paint stirrer AR42, a bucket for mixing, a drilling machine (electric
screwdriver) and 15-30 minutes of your time.

General advantages of powder paints:

Has a very long shelf life without water


No preservatives necessary
Reduced risk of frost damages
50-80 % less plastic waste
Less delivery costs (up to 60 %)
More security during transit in case of packaging damages
Small partial quantities can be taken out of the bag for necessary repair works
Screening attenuation
At a yield of 4 sqm/l:
At 1 GHz: Single layer 36 dB | Double layer 41 dB | Three layer 46 dB
At a yield of 8 sqm/l:
At 1 GHz: Single layer 30 dB | Double layer 36 dB | Three layer 40 dB
Grounding
Must be grounded! We recommend interior the grounding strap GSX plus grounding plate GS / GF,
exterior the fiber additive AF3 plus the grounding plate GF4.
Frost resistance
This product is delivered as a powder and thus frost resistant.
Ingredients
Untreated natural graphite, carbon black, pure acrylics powder, additives, no preservative agent.
Technical data
Please find all technical data and the application details in our technical data sheet.
Ready for 5G
As we keep on developing our paints, they now have an almost linear shielding attenuation for a very
large frequency range. This frequency range has already been including both 5G frequency spectrums
for quite some time: FR1 (600 MHz - 6 GHz) and FR2 (24 GHz - 40 GHz).
Safety up to 40 GHz
We already invested in our own professional EMV laboratory many years ago, as external
laboratories and experts could no longer fulfil our increasing expectation to a 140 dB measuring
dynamics and 40 GHz. We not only issue our own shielding reports therein but also check each and
every batch for your security on a daily basis. You receive measuring curves and laboratory reports up
to 40 GHz with each of our shielding products, by which we bindingly guarantee the shielding
effectiveness.
YSHIELD GmbH & Co. KG, Rotthofer Straße 1, 94099 Ruhstorf, Germany, www.yshield.com, info@yshield.com, 0049-8531-31713-0
Attenuation at 1/40 GHz. Shielding reports, certifications, data sheets, weight, sizes, GTIN, COO, TARIFF, etc. on our website.
No nanotechnology
Our shielding paints are developed in accordance with strict ecological criteria. We use, for example,
the carbon black with the lowest emission possible on the market and untreated natural graphite. We
consciously do not use graphene, a nanomaterial where the hazard potential is still completely
unknown.

YSHIELD GmbH & Co. KG, Rotthofer Straße 1, 94099 Ruhstorf, Germany, www.yshield.com, info@yshield.com, 0049-8531-31713-0
Attenuation at 1/40 GHz. Shielding reports, certifications, data sheets, weight, sizes, GTIN, COO, TARIFF, etc. on our website.
YSHIELD® YSHIELD® GmbH & Co. KG, Rotthofer Straße 1, 94099 Ruhstorf, Germany
Fon: 0049-(0)8531-31713-0, Email: info@yshield.com, Web: www.yshield.com

Prüfbericht Schirmdämpfung Laboratory report screening attenuation


Prüfobjekt Test object Shielding paint DRY54 | 4 m2/l
600 MHz 1 GHz
Screening attenuation to IEEE 1-layer 2-layer 3-layer
10 GHz 15 GHz 40 GHz 
Abschirmfarbe Shielding paint
DRY54 mit Malerwalze. DRY54 with paint roller.
-10 dB
Dick 4 m2/l + Dünn 8 m2/l Thick 4 m2/l + Thin 8 m2/l
Prüfdatum Test date -20 dB
11.05.2021 2021/05/11
Garantie Guarantee -30 dB
 36 dB
Mit diesem Prüfbericht We bindingly guarantee
garantieren wir verbindlich the shielding attenuation -40 dB  41 dB
die Schirmdämpfung of a product with this  46 dB
eines Produktes. Die laboratory report. The -50 dB

Kurven repräsentieren diagrams represents the


den Mittelwert aller mean value of all tested -60 dB

geprüfter Chargen in einem charges, within a tolerance


Toleranzbereich von +/- 2 dB. range of +/- 2 dB. -70 dB

Prüfort Place of test -80 dB


Eigenes professionelles EMV- Own professional EMC-
Labor nach internationalen laboratory according to -90 dB
Standards, zur täglichen international standards, for
Qualitätssicherung und daily quality control and -100 dB © YSHIELD GmbH & Co. KG
Produktentwicklung. product development. GSM / UMTS
LTE
Konformität Conformity 5G 5G

Die Messung der Dämpfung The measurement


elektromagnetischer Wellen of the attenuation of Shielding paint DRY54 | 8 m2/l Screening attenuation to IEEE 1-layer 2-layer 3-layer
von 600 MHz bis 40 GHz electromagnetic waves from 600 MHz 1 GHz 10 GHz 15 GHz 40 GHz 

wurde in enger Anlehnung 600 MHz to 40 GHz has


an die Standards IEEE Std been performed in close -10 dB
299™-2006 oder ASTM accordance with standards
D4935-10 durchgeführt. IEEE Std 299™-2006 or -20 dB
ASTM D4935-10.
Prüfaufbau
-30 dB  30 dB
Messgeräte: Vektorielle Test setup
 36 dB
Netzwerkanalysatoren Measuring devices: Vector -40 dB  40 dB
Rohde & Schwarz ZNB20 Network Analysers Rohde &
und ZNB40 mit einer Schwarz ZNB20 and ZNB40 -50 dB
Messdynamik bis 140 dB. with a measuring dynamics
Antennen: Für IEEE Std up to 140 dB. -60 dB
299™-2006 Hornantennen Antennas: For IEEE Std
mit horizontaler/vertikaler 299™-2006 horn antennas -70 dB
Polarisation innerhalb und with horizontal/vertical
ausserhalb einer Prüfkammer. polarisation inside and -80 dB
Für ASTM D4935-10 outside a test chamber. For
TEM-Zellen mit radialer ASTM D4935-10 TEM cells -90 dB
Polarisation. with radial polarisation.
Prüfdurchführung Test implementation -100 dB © YSHIELD GmbH & Co. KG
GSM / UMTS
Bestrahlung mit der Leis- Irradiation with the power LTE
5G 5G
tungsflussdichte S1. flux density S1. Measuring the
Messung der durchdringen- pervasive power flux den-
den Leistungsflussdichte S2. sity S2. The shielding atten-
Die Schirmdämpfung ist eine uation is a non-dimensional
dimensionslose Messgröße in measured variable in deci-
Dezibel (dB): bels (dB):

dB Dämpfung dB Attenuation
10 90 % 10 90 %
20 99 % 20 99 %
30 99,9 % 30 99.9 %
40 99,99 % 40 99.99 %
50 99,999 % 50 99.999 %
60 99,9999 % 60 99.9999 %
... ... ... ...
YSHIELD® NSF34 | Low frequency shielding paint | 5 liter
Low frequency shielding paint against electrical fields. Up to 80 dB = 99.99 %. TÜV-SÜD certified. To shield electrical devices,
fuse boxes, power lines, etc.

As shielding paint for rooms and buildings


Shielding paint for shielding low-frequency electric fields (LF) only. No magnetic fields are
shielded. Standard shielding paint for low-frequency electrical fields. TÜV-SÜD certified.
To shield electrical devices, fuse boxes, power lines, etc. Breathable, solvent-free,
plasticizer-free and low-emission. With phenomenal physical and chemical properties, along with
high ecology.
Screening attenuation
Single layer up to 80 dB = 99.99 % (depending on quality of grounding)
Underground
Excellent adhesion on almost all substrates interior and exterior.
Top coating
Preferably covered with plastic bonded water-based emulsion paints, dispersion silicate paints,
facade paints or silicon resin paints.
Grounding
Must be grounded! We recommend interior the grounding strap EBX plus grounding plate GW,
exterior the fiber additive AF3 plus the grounding plate GE.
Optional: Fiber additive AF3
For crack bridging and a better grounding we advise our fiber additive AF3 with long conductive
carbon fibers.
Frost resistance
This product is frost resistant (proved for 5 frost-/thaw cycles) and can be shipped throughout the
year by air cargo or ship.
Ingredients
Water, pure acrylics dispersion, carbon black, natural graphite, additives, preservative (BIT, INN,
MIT).
Technical data
Please find detailled data in the table overview and the technical data sheet.
No nanotechnology
Our shielding paints are developed in accordance with strict ecological criteria. We use, for
example, the carbon black with the lowest emission possible on the market and untreated natural
graphite. We consciously do not use graphene, a nanomaterial where the hazard potential is
still completely unknown.
TÜV-SÜD certification
We have our shielding paints monitored by TÜV-SÜD. The whole production process
including quality control, emission behaviour and economical use of preserving agents is subject
to monitoring. Please find the certificate above at the downloads.

YSHIELD GmbH & Co. KG, Rotthofer Straße 1, 94099 Ruhstorf, Germany, www.yshield.com, info@yshield.com, 0049-8531-31713-0
Attenuation at 1/40 GHz. Expert reports, certifications, data sheets, weight, sizes, GTIN, COO, TARIFF, etc. on our website.
YSHIELD® HSF64 | Standard shielding paint | 5 liter
Standard paint without preservatives on basis of dispersion silicate, minimalistic formulation. Up to 80 dB. TÜV-SÜD certified.
Very high ecology.

As shielding paint for rooms and buildings


Shielding paint for shielding high-frequency radiation (HF) and low-frequency electric fields
(LF). Standard shielding paint without preservatives on basis of dispersion silicate,
minimalistic formulation. TÜV-SÜD certified. High ecology with fine pigmentation.
Limitations at adhesion and shielding. Breathable, solvent-free, plasticizer-free, low-emission
and without preservation agent.
Screening attenuation
At 1 GHz: Single layer 37 dB | Double layer 47 dB | Three layer 57 dB
At 40 GHz: Single layer 37 dB | Double layer 55 dB | Three layer 80 dB
Underground
Adhesion on almost all absorbent substrates interior.
Top coating
Preferably covered with plastic bonded water-based emulsion paints, dispersion silicate paints or
silicon resin paints.
Grounding
Must be grounded! We recommend interior the grounding strap EBX plus grounding plate GW.
Frost resistance
This product is frost resistant (proved for 5 frost-/thaw cycles) and can be shipped throughout the
year by air cargo or ship.
Ingredients
Water, potassium silicate, natural graphite, carbon black, pure acrylics dispersion, additives, NO
preservation agent.
Technical data
Please find detailled data in the table overview and the technical data sheet.
Ready for 5G
As we keep on developing our paints, they now have an almost linear shielding attenuation for a
very large frequency range. This frequency range has already been including both 5G frequency
spectrums for quite some time: FR1 (600 MHz - 6 GHz) and FR2 (24 GHz - 40 GHz).
Safety up to 40 GHz
We have a professional EMC-laboratory according to various standards up to 40 GHz on site, which
is operated by long-time experienced staff. You’ll receive measuring curves and reports from
40/600 MHz - 40 GHz with all our shielding products.
No nanotechnology
Our shielding paints are developed in accordance with strict ecological criteria. We use, for
example, the carbon black with the lowest emission possible on the market and untreated natural
graphite. We consciously do not use graphene, a nanomaterial where the hazard potential is
still completely unknown.
TÜV-SÜD certification
We have our shielding paints monitored by TÜV-SÜD. The whole production process
including quality control, emission behaviour and economical use of preserving agents is subject
to monitoring. Please find the certificate above at the downloads.

YSHIELD GmbH & Co. KG, Rotthofer Straße 1, 94099 Ruhstorf, Germany, www.yshield.com, info@yshield.com, 0049-8531-31713-0
Attenuation at 1/40 GHz. Expert reports, certifications, data sheets, weight, sizes, GTIN, COO, TARIFF, etc. on our website.
YSHIELD® YSHIELD® GmbH & Co. KG, Rotthofer Straße 1, 94099 Ruhstorf, Germany
Fon: 0049-(0)8531-31713-0, Email: info@yshield.com, Web: www.yshield.com

Gutachten Schirmdämpfung Expert report screening attenuation


Messobjekt Measuring object Screening attenuation Shielding paint HSF64
40 MHz 100 MHz 600 MHz 1 GHz
Single layer Double layer Three layer
10 GHz 40 GHz 
Abschirmfarbe HSF64 Shielding paint HSF64
mit Malerwalze with paint roller -10 dB
Datum der Messung Date of measurement
-20 dB
22.10.2020 2020/10/22
Vorbemerkung Preliminary Note -30 dB

Die Prüflinge werden The test samples are 


mit einer definierten irradiated with a defined -40 dB

Leistungsflussdichte S1 power flux density S1, 


-50 dB
bestrahlt, die durchdringende the pervasive power flux
Leistungsflussdichte density is measured. The 
-60 dB
S2 wird gemessen. Die shielding attenuation is a
Schirmdämpfung ist eine non-dimensional measured
-70 dB
dimensionslose Messgröße variable in decibels (dB) and
in Dezibel (dB) und wird wie calculated as follows: -80 dB
folgt berechnet:
-90 dB

dB Attenuation
dB Dämpfung 10 90 % -100 dB © YSHIELD GmbH & Co. KG
DVB-T GSM / UMTS
10 90 % 20 99 % LTE
20 99 % 30 99.9 % 5G 5G

30 99,9 % 40 99.99 %
40 99,99 % 50 99.999 % 40 MHz - 40 GHz
50 99,999 % 60 99.9999 %
60 99,9999 % ... ...
... ... Einlagig / Single layer
Conformity 10/22/2020 9:58:28 AM

Konformität
1311.6010K72-101750-NK

The measurement Trc1


00dB
S21 dB Mag 10 dB/ Ref 0 dB Cal Smo 1

M1 1.000000 GHz -37.0090 dB

Die Messung der Dämpfung of the attenuation of


-10

-20

elektromagnetischer Wellen electromagnetic waves -30


M1

von 40/600 MHz bis 40 GHz between 40/600 MHz


-40

-50

wurde (wahlweise je nach – 40 GHz (selectively -60

Materialeigenschaften) in depending on the material


-70

-80

Übereinstimmung mit dem properties) has been -90

7E+7 1E+8 2E+8 3E+8 4E+8 5E+8 7E+8 1E+9 2E+9 3E+9 4E+9 5E+9 7E+9 1E+10 2E+10 4E+10

Standard IEEE Std 299™- conducted in accordance


-100

Ch1 Start 40 MHz Pwr 8 dBm Bw 100 Hz Stop 40 GHz

2006 oder in Anlehnung an with standard IEEE Std Zweilagig / Two layer
den Standard ASTM D4935- 299™-2006 or following to Trc1
00dB
10/22/2020 9:59:14 AM
1311.6010K72-101750-NK

S21 dB Mag 10 dB/ Ref 0 dB Cal Smo 1

M1 1.000000 GHz -47.9241 dB

10 durchgeführt. standard ASTM D4935-10. -10

-20

Ort der Messung Place of measurement -30

-40

Eigenes EMV-Labor nach In our own EMV laboratory -50


M1

gängigen etablierten according to prevalent -60

-70

Standards, zur täglichen established standards, for -80

Qualitätssicherung und daily quality control and -90

-100
7E+7 1E+8 2E+8 3E+8 4E+8 5E+8 7E+8 1E+9 2E+9 3E+9 4E+9 5E+9 7E+9 1E+10 2E+10 4E+10

Produktentwicklung. product development.


Ch1 Start 40 MHz Pwr 8 dBm Bw 100 Hz Stop 40 GHz

Dreilagig / Three layer


Messaufbau Measurement setup 10/22/2020 10:01:34 AM
1311.6010K72-101750-NK

Trc1 S21 dB Mag 10 dB/ Ref 0 dB Cal Math Smo 1

Als Messgeräte verwenden The measuring devices we


00dB
M1 1.000000 GHz -57.0037 dB

-10

wir zwei vektorielle use are two Vector Network -20

Netzwerkanalysatoren Analysers Rhode & Schwarz


-30

-40

Rohde & Schwarz ZNB20 ZNB20 and ZNB40, with a -50


M1

und ZNB40 mit einer measuring dynamics up to


-60

-70

Messdynamik bis 140 dB. 140 dB. -80

-90

Als Antennen für IEEE Std The antennas we use for -100
7E+7

Ch1 Start 40 MHz


1E+8 2E+8 3E+8 4E+8 5E+8 7E+8 1E+9

Pwr 8 dBm Bw 100 Hz


2E+9 3E+9 4E+9 5E+9 7E+9 1E+10 2E+10 4E+10

Stop 40 GHz

299™-2006 verwenden wir IEEE Std 299™-2006 are


breitbandige Hornantennen. broadband horn antennas.
Als Antennen für ASTM The antennas we use
D4935-10 verwenden wir for ASTM D4935-10 are
breitbandige TEM-Zellen mit broadband TEM cells with
radialer Polarisation. radial polarisation.
YSHIELD® MAX54 | Special shielding paint | 5 liter
Special paint with the focus on maximum shielding, if every single dB counts. Up to 83 dB. Limitations at hardness and
abrasion resistance.

As shielding paint for rooms and buildings


Shielding paint for shielding high-frequency radiation (HF) and low-frequency electric fields
(LF). Special shielding paint with the focus on maximum shielding, if every single dB
counts. Limitations at hardness and abrasion resistance. Breathable, solvent-free,
plasticizer-free and low-emission. With phenomenal physical and chemical properties, along with
high ecology.
Screening attenuation
At 1 GHz: Single layer 43 dB | Double layer 53 dB | Three layer 63 dB
At 40 GHz: Single layer 50 dB | Double layer 71 dB | Three layer 83 dB
Underground
Excellent adhesion on almost all substrates interior and exterior.
Top coating
Preferably covered with plastic bonded water-based emulsion paints, dispersion silicate paints,
facade paints or silicon resin paints.
Grounding
Must be grounded! We recommend interior the grounding strap EBX plus grounding plate GW,
exterior the fiber additive AF3 plus the grounding plate GE.
Optional: Fiber additive AF3
For crack bridging and a better grounding we advise our fiber additive AF3 with long conductive
carbon fibers.
Frost resistance
This product is frost resistant (proved for 5 frost-/thaw cycles) and can be shipped throughout the
year by air cargo or ship.
Ingredients
Water, natural graphite, pure acrylics dispersion, carbon black, additives, preservative (BIT, INN,
MIT).
Technical data
Please find detailled data in the table overview and the technical data sheet.
Ready for 5G
As we keep on developing our paints, they now have an almost linear shielding attenuation for a
very large frequency range. This frequency range has already been including both 5G frequency
spectrums for quite some time: FR1 (600 MHz - 6 GHz) and FR2 (24 GHz - 40 GHz).
Safety up to 40 GHz
We have a professional EMC-laboratory according to various standards up to 40 GHz on site, which
is operated by long-time experienced staff. You’ll receive measuring curves and reports from
40/600 MHz - 40 GHz with all our shielding products.
No nanotechnology
Our shielding paints are developed in accordance with strict ecological criteria. We use, for
example, the carbon black with the lowest emission possible on the market and untreated natural
graphite. We consciously do not use graphene, a nanomaterial where the hazard potential is
still completely unknown.

YSHIELD GmbH & Co. KG, Rotthofer Straße 1, 94099 Ruhstorf, Germany, www.yshield.com, info@yshield.com, 0049-8531-31713-0
Attenuation at 1/40 GHz. Expert reports, certifications, data sheets, weight, sizes, GTIN, COO, TARIFF, etc. on our website.
YSHIELD® YSHIELD® GmbH & Co. KG, Rotthofer Straße 1, 94099 Ruhstorf, Germany
Fon: 0049-(0)8531-31713-0, Email: info@yshield.com, Web: www.yshield.com

Gutachten Schirmdämpfung Expert report screening attenuation


Messobjekt Measuring object Screening attenuation Shielding paint MAX54
40 MHz 100 MHz 600 MHz 1 GHz
Single layer Double layer Three layer
10 GHz 40 GHz 
Abschirmfarbe MAX54 Shielding paint MAX54
mit Malerwalze with paint roller -10 dB
Datum der Messung Date of measurement
-20 dB
25.05.2020 2020/05/25
Vorbemerkung Preliminary Note -30 dB

Die Prüflinge werden The test samples are


mit einer definierten irradiated with a defined -40 dB

Leistungsflussdichte S1 power flux density S1,
-50 dB
bestrahlt, die durchdringende the pervasive power flux 
Leistungsflussdichte density is measured. The
-60 dB
S2 wird gemessen. Die shielding attenuation is a 
Schirmdämpfung ist eine non-dimensional measured
-70 dB
dimensionslose Messgröße variable in decibels (dB) and
in Dezibel (dB) und wird wie calculated as follows: -80 dB
folgt berechnet:
-90 dB

dB Attenuation
dB Dämpfung 10 90 % -100 dB © YSHIELD GmbH & Co. KG
DVB-T GSM / UMTS
10 90 % 20 99 % LTE
20 99 % 30 99.9 % 5G 5G

30 99,9 % 40 99.99 %
40 99,99 % 50 99.999 % 40 MHz - 40 GHz
50 99,999 % 60 99.9999 %
60 99,9999 % ... ...
... ... Einlagig / Single layer
Conformity 5/26/2020 3:46:24 PM

Konformität
1311.6010K72-101750-NK

The measurement Trc1


00dB
S21 dB Mag 10 dB/ Ref 0 dB Cal Smo 1

1 1.000000 GHz -43.3990 dB

Die Messung der Dämpfung of the attenuation of


-10

-20

elektromagnetischer Wellen electromagnetic waves -30

von 40/600 MHz bis 40 GHz between 40/600 MHz


-40 1

-50

wurde (wahlweise je nach – 40 GHz (selectively -60

Materialeigenschaften) in depending on the material


-70

-80

Übereinstimmung mit dem properties) has been -90

7E+7 1E+8 2E+8 3E+8 4E+8 5E+8 7E+8 1E+9 2E+9 3E+9 4E+9 5E+9 7E+9 1E+10 2E+10 4E+10

Standard IEEE Std 299™- conducted in accordance


-100

Ch1 Start 40 MHz Pwr 8 dBm Bw 100 Hz Stop 40 GHz

2006 oder in Anlehnung an with standard IEEE Std Zweilagig / Two layer
den Standard ASTM D4935- 299™-2006 or following to Trc1
00dB
5/26/2020 3:49:11 PM
1311.6010K72-101750-NK

S21 dB Mag 10 dB/ Ref 0 dB Cal Math Smo 1

1 1.000000 GHz -53.4656 dB

10 durchgeführt. standard ASTM D4935-10. -10

-20

Ort der Messung Place of measurement -30

-40

Eigenes EMV-Labor nach In our own EMV laboratory -50 1

gängigen etablierten according to prevalent -60

-70

Standards, zur täglichen established standards, for -80

Qualitätssicherung und daily quality control and -90

-100
7E+7 1E+8 2E+8 3E+8 4E+8 5E+8 7E+8 1E+9 2E+9 3E+9 4E+9 5E+9 7E+9 1E+10 2E+10 4E+10

Produktentwicklung. product development.


Ch1 Start 40 MHz Pwr 8 dBm Bw 100 Hz Stop 40 GHz

Dreilagig / Three layer


Messaufbau Measurement setup 5/26/2020 3:48:31 PM
1311.6010K72-101750-NK

Trc1 S21 dB Mag 10 dB/ Ref 0 dB Cal Math Smo 1

Als Messgeräte verwenden The measuring devices we


00dB
1 1.000000 GHz -63.3771 dB

-10

wir zwei vektorielle use are two Vector Network -20

Netzwerkanalysatoren Analysers Rhode & Schwarz


-30

-40

Rohde & Schwarz ZNB20 ZNB20 and ZNB40, with a -50

und ZNB40 mit einer measuring dynamics up to


-60 1

-70

Messdynamik bis 140 dB. 140 dB. -80

-90

Als Antennen für IEEE Std The antennas we use for -100
7E+7

Ch1 Start 40 MHz


1E+8 2E+8 3E+8 4E+8 5E+8 7E+8 1E+9

Pwr 8 dBm Bw 100 Hz


2E+9 3E+9 4E+9 5E+9 7E+9 1E+10 2E+10 4E+10

Stop 40 GHz

299™-2006 verwenden wir IEEE Std 299™-2006 are


breitbandige Hornantennen. broadband horn antennas.
Als Antennen für ASTM The antennas we use
D4935-10 verwenden wir for ASTM D4935-10 are
breitbandige TEM-Zellen mit broadband TEM cells with
radialer Polarisation. radial polarisation.
YSHIELD® PRO54 | Special shielding paint | 5 liter
Special paint with the focus on hardness and abrasion resistance due to carbon fibers. Up to 52 dB. TÜV-SÜD certified.
Limitations only at shielding.

As shielding paint for rooms and buildings


Shielding paint for shielding high-frequency radiation (HF) and low-frequency electric fields
(LF). Special shielding paint with the focus on hardness and abrasion resistance due to
carbon fibers. TÜV-SÜD certified. Limitations only at shielding. Breathable, solvent-free,
plasticizer-free and low-emission. With phenomenal physical and chemical properties, along with
high ecology.
Screening attenuation
At 1 GHz: Single layer 32 dB | Double layer 40 dB | Three layer 48 dB
At 40 GHz: Single layer 33 dB | Double layer 42 dB | Three layer 52 dB
Underground
Excellent adhesion on almost all substrates interior and exterior.
Top coating
Preferably covered with plastic bonded water-based emulsion paints, dispersion silicate paints,
facade paints or silicon resin paints.
Grounding
Must be grounded! We recommend interior the grounding strap EBX plus grounding plate GW,
exterior the fiber additive AF3 plus the grounding plate GE.
Optional: Fiber additive AF3
For crack bridging and a better grounding we advise our fiber additive AF3 with long conductive
carbon fibers.
Frost resistance
This product is frost resistant (proved for 5 frost-/thaw cycles) and can be shipped throughout the
year by air cargo or ship.
Ingredients
Water, pure acrylics dispersion, carbon fibers, natural graphite, carbon black, additives,
preservative (BIT, INN, MIT).
Technical data
Please find detailled data in the table overview and the technical data sheet.
Ready for 5G
As we keep on developing our paints, they now have an almost linear shielding attenuation for a
very large frequency range. This frequency range has already been including both 5G frequency
spectrums for quite some time: FR1 (600 MHz - 6 GHz) and FR2 (24 GHz - 40 GHz).
Safety up to 40 GHz
We have a professional EMC-laboratory according to various standards up to 40 GHz on site, which
is operated by long-time experienced staff. You’ll receive measuring curves and reports from
40/600 MHz - 40 GHz with all our shielding products.
No nanotechnology
Our shielding paints are developed in accordance with strict ecological criteria. We use, for
example, the carbon black with the lowest emission possible on the market and untreated natural
graphite. We consciously do not use graphene, a nanomaterial where the hazard potential is
still completely unknown.
TÜV-SÜD certification
We have our shielding paints monitored by TÜV-SÜD. The whole production process
including quality control, emission behaviour and economical use of preserving agents is subject
to monitoring. Please find the certificate above at the downloads.

YSHIELD GmbH & Co. KG, Rotthofer Straße 1, 94099 Ruhstorf, Germany, www.yshield.com, info@yshield.com, 0049-8531-31713-0
Attenuation at 1/40 GHz. Expert reports, certifications, data sheets, weight, sizes, GTIN, COO, TARIFF, etc. on our website.
YSHIELD® YSHIELD® GmbH & Co. KG, Rotthofer Straße 1, 94099 Ruhstorf, Germany
Fon: 0049-(0)8531-31713-0, Email: info@yshield.com, Web: www.yshield.com

Gutachten Schirmdämpfung Expert report screening attenuation


Messobjekt Measuring object Screening attenuation Shielding paint PRO54
40 MHz 100 MHz 600 MHz 1 GHz
Single layer Double layer Three layer
10 GHz 40 GHz 
Abschirmfarbe PRO54 Shielding paint PRO54
mit Malerwalze with paint roller -10 dB
Datum der Messung Date of measurement
-20 dB
18.12.2019 2019/12/18
Vorbemerkung Preliminary Note -30 dB

Die Prüflinge werden The test samples are
mit einer definierten irradiated with a defined -40 dB 

Leistungsflussdichte S1 power flux density S1,


-50 dB 
bestrahlt, die durchdringende the pervasive power flux
Leistungsflussdichte density is measured. The
-60 dB
S2 wird gemessen. Die shielding attenuation is a
Schirmdämpfung ist eine non-dimensional measured
-70 dB
dimensionslose Messgröße variable in decibels (dB) and
in Dezibel (dB) und wird wie calculated as follows: -80 dB
folgt berechnet:
-90 dB

dB Attenuation
dB Dämpfung 10 90 % -100 dB © YSHIELD GmbH & Co. KG
DVB-T GSM / UMTS
10 90 % 20 99 % LTE
20 99 % 30 99,9 % 5G 5G

30 99,9 % 40 99,99 %
40 99,99 % 50 99,999 % 40 MHz - 40 GHz
50 99,999 % 60 99,9999 %
60 99,9999 % ... ...
... ... Einlagig / Single layer
Conformity 12/18/2019 3:51:39 PM

Konformität
1311.6010K72-101750-NK

The measurement Trc1


00dB
S21 dB Mag 10 dB/ Ref 0 dB Cal Math Smo 1

M1 1.000000 GHz -32.3842 dB

Die Messung der Dämpfung of the attenuation of


-10

-20

elektromagnetischer Wellen electromagnetic waves -30


M1

von 40/600 MHz bis 40 GHz between 40/600 MHz


-40

-50

wurde (wahlweise je nach – 40 GHz (selectively -60

Materialeigenschaften) in depending on the material


-70

-80

Übereinstimmung mit dem properties) has been -90

7E+7 1E+8 2E+8 3E+8 4E+8 5E+8 7E+8 1E+9 2E+9 3E+9 4E+9 5E+9 7E+9 1E+10 2E+10 4E+10

Standard IEEE Std 299™- conducted in accordance


-100

Ch1 Start 40 MHz Pwr 8 dBm Bw 100 Hz Stop 40 GHz

2006 oder in Anlehnung an with standard IEEE Std Zweilagig / Two layer
den Standard ASTM D4935- 299™-2006 or following to Trc1
00dB
12/18/2019 3:53:38 PM
1311.6010K72-101750-NK

S21 dB Mag 10 dB/ Ref 0 dB Cal Math Smo 1

M1 1.000000 GHz -40.1913 dB

10 durchgeführt. standard ASTM D4935-10. -10

-20

Ort der Messung Place of measurement -30

M1
-40

Eigenes EMV-Labor nach In our own EMV laboratory -50

gängigen etablierten according to prevalent -60

-70

Standards, zur täglichen established standards, for -80

Qualitätssicherung und daily quality control and -90

-100
7E+7 1E+8 2E+8 3E+8 4E+8 5E+8 7E+8 1E+9 2E+9 3E+9 4E+9 5E+9 7E+9 1E+10 2E+10 4E+10

Produktentwicklung. product development.


Ch1 Start 40 MHz Pwr 8 dBm Bw 100 Hz Stop 40 GHz

Dreilagig / Three layer


Messaufbau Measurement setup 12/18/2019 3:54:31 PM
1311.6010K72-101750-NK

Trc1 S21 dB Mag 10 dB/ Ref 0 dB Cal Math Smo 1

Als Messgeräte verwenden The measuring devices we


00dB
M1 1.000000 GHz -48.5222 dB

-10

wir zwei vektorielle use are two Vector Network -20

Netzwerkanalysatoren Analysers Rhode & Schwarz


-30

-40

Rohde & Schwarz ZNB20 ZNB20 and ZNB40, with a


M1
-50

und ZNB40 mit einer measuring dynamics up to


-60

-70

Messdynamik bis 140 dB. 140 dB. -80

-90

Als Antennen für IEEE Std The antennas we use for -100
7E+7

Ch1 Start 40 MHz


1E+8 2E+8 3E+8 4E+8 5E+8 7E+8 1E+9

Pwr 8 dBm Bw 100 Hz


2E+9 3E+9 4E+9 5E+9 7E+9 1E+10 2E+10 4E+10

Stop 40 GHz

299™-2006 verwenden wir IEEE Std 299™-2006 are


breitbandige Hornantennen. broadband horn antennas.
Als Antennen für ASTM The antennas we use
D4935-10 verwenden wir for ASTM D4935-10 are
breitbandige TEM-Zellen mit broadband TEM cells with
radialer Polarisation. radial polarisation.

Das könnte Ihnen auch gefallen