TAG NUMBER 440TGTG-002 DESCRIPTION STEAM TURBINE GENERATOR
LOCATION EPC-2 DATE & TIME 03-01-2023 14:30 HRS AREA 2 ITW NO UNIT NAME STEAM TURBINE GENERATION SY EPC 2 Technical Data SPEED* RPM RATED POWER KW NA NPSH AVAILABLE NA ROTATION* (Direction) NA SUCTION PRESSURE SUCTION TEMP. STARTING CURRENT NA DISCHARGE PRESSURE DISCHARGE TEMP. RATED CURRENT* NA DISCHARGE FLOW RATE NPSH AVAILABLE POWER CONSUMED NA MINIMUM FLOW (data sheet) DESIGN FLOW Test Liquid/gas – HC or Water or Air STEAM Design suction pressure Design discharge Pre
MEASUREMENTS SUMMARY
DIRECTION & PROBE TAG (um
microns) Measurement TIME TIME 16:05 PM (1867 rpm) 17:10PM 1850 RPM TURBINE 1st 2nd TNDE-H 440VT-9201-X 27um 15um TNDE-V 440VT-9201-Y 11um 15um TDE-H 440VT-9202-X 8um 25um TDE-H 440VT-9202-Y 21um 15um NDE TEMP- 440-TE-9216-AB 44 C 43 C NDE TEMP- 440-TE-9217-AB 42 C 41 C DE TEMP- 440-TE-9218-AB 39 C 41 C DE TEMP- 440-TE-9219-AB 39 C 40 C GEARBOX
GHDE-H 440-VT-9203-X 19um 24um
GHDE-V 440-VT-9203-Y 35um 15um GHNDE-H 440-VT-9204-X 18um 21um GHNDE-V 440-VT-9204-Y 39um 35.00 GHDE TEMP 440-TE-9222-AB 40 C 40 C GHDE TEMP 440-TE-9223-AB 41 C 41 C GHNDE TEMP 440-TE-9224-AB 40 C 40 C GHNDE TEMP 440-TE-9225-AB 41 C 41 C GLDE-H 440-VT-9206-X 21um 13um GLDE-H 440-VT-9206-Y 41um 36um GLNDE-H 440-VT-9205-X 7um 8um GLNDE-H 440-VT-9205-Y 25um 11um GLDE TEMP 440-TE-9232-AB 39 C 39 C GLDE TEMP 440-TE-9233-AB 39 C 39 C GLNDE TEMP 440-TE-9230-AB 40 C 39 C GLNDE TEMP 440-TE-9231-AB 39 C 38 C GENERATOR
GDE-H 440-VT-9210-X 9um 7um
GDE-H 440-VT-9210-Y 19um 6um GNDE-H 440-VT-9211-X 48um 57um GNDE-H 440-VT-9211-V 25um 41um GDE TEMP 440-TE-9236-AB 43 C 42 C GNDE TEMP 440-TE-9237-AB 42 C 41 C