Beruflich Dokumente
Kultur Dokumente
SCN 35
SCN 45S
D5 SCN 75
SCN 125
SCN 215
Automatic cubers
Automatic Kegeleisbereiter
Introduction 1 Einführung 14
Unpacking and inspection 1 Auspacken und Inspektion 14
Location and levelling 1 Maschinenplatz und lotgerechte Austellung 14
Electrical connection 1 Elektrische Anschlüße 15
Water supply and drain connection 2 Wasserversorgung und Abflußleitungen 15
Final check list 3 Schlußkontrollen 15
Installation practice 3 Installation 16
Starp up 4 Inbetriebnahme 17
Operational checks 4 Ueberprüfung im Betrieb 17
General 12 Woraussetzung 25
Icemaker 12 Reinigung des Eisbereiters 25
Clean - Replace of air condenser filter 12 Reinigung - Austausch des Luftkondensatorfilters 25
Cleaning instructions of water system 12 Wartungs und Reinigungsanleitungen 26
B
Ice making capacity - Eisproduktionskapazität
SD 22 SD 23
WATER TEMPERATURE - WASSERTEMPERATUR WATER TEMPERATURE - WASSERTEMPERATUR WATER TEMPERATURE - WASSERTEMPERATUR WATER TEMPERATURE - WASSERTEMPERATUR
SD 30 SCN 35
ICE PRODUCED PER 24 HRS. - EISWÜRFEL PRODUKTION IN 24 STD.
20 20 29 29
25 20 15 10 °C 25 20 15 10 °C 25 20 15 10 °C 25 20 15 10 °C
WATER TEMPERATURE - WASSERTEMPERATUR WATER TEMPERATURE - WASSERTEMPERATUR WATER TEMPERATURE - WASSERTEMPERATUR WATER TEMPERATURE - WASSERTEMPERATUR
SCN 45 SCN 75
ICE PRODUCED PER 24 HRS. - EISWÜRFEL PRODUKTION IN 24 STD.
AIR COOLED MODELS - LUFTKÜHLUNG WATER COOLED MODELS - WASSERKÜHLUNG AIR COOLED MODELS - LUFTKÜHLUNG WATER COOLED MODELS - WASSERKÜHLUNG
AMBIENT TEMPERATURE - RAUMTEMPERATUR
60 10 60 10 80 10 82
20
78
58 20 58 20 80
30 76
56 56 35 74 78
54 54 72 76
70 30
52 30 52 74
68
50 50 66 72
48 35 48 64 35 70
62
46 46 68
60
44 44 58 66
25 20 15 10 °C 25 20 15 10 °C 25 20 15 10 °C 25 20 15 10 °C
WATER TEMPERATURE - WASSERTEMPERATUR WATER TEMPERATURE - WASSERTEMPERATUR WATER TEMPERATURE - WASSERTEMPERATUR WATER TEMPERATURE - WASSERTEMPERATUR
AIR COOLED MODELS - LUFTKÜHLUNG WATER COOLED MODELS - WASSERKÜHLUNG AIR COOLED MODELS - LUFTKÜHLUNG WATER COOLED MODELS - WASSERKÜHLUNG
AMBIENT TEMPERATURE - RAUMTEMPERATUR
WATER TEMPERATURE - WASSERTEMPERATUR WATER TEMPERATURE - WASSERTEMPERATUR WATER TEMPERATURE - WASSERTEMPERATUR WATER TEMPERATURE - WASSERTEMPERATUR
C
B A
C
1 2 3
SDN 25 - 30
B A
1 2 3
SCN 35 - 45
SDN 25 (mm) SDN 30 (mm) SDN 35 (mm) SCN 35 (mm) SCN 45 (mm)
A 334 377 377 485 485
B 454 552 552 572 572
C 597 637 637 721 816
D
B A
C
➀ ➁➂ ➃ ➄
SCN 75
B A
C
➀➁➂➃ ➄
Water Cooled
8,5÷10 bar 8,5÷10 bar 9,5 bar 17 bar 17 bar
Wassergekuhlt
0,8÷0,1 bar 0,8÷0,1 bar 0,8÷0,1 bar 3,6÷1,5 bar 2,4÷1,3 bar
WIRING DIAGRAM - SCHALTUNGSSCHEMA
230/50/1
AIR & WATER COOLED - LUFT UND WASSERGEKÜHLT
SCN 35-45-75
WIRING DIAGRAM - SCHALTUNGSSCHEMA
230/50/1
AIR & WATER COOLED - LUFT UND WASSERGEKÜHLT
SCN 125 – SCN 215
Page 1
6. Check that refrigerant lines do not rub 2. Level the Icemaker in both the left to right
against or touch other lines or surfaces, and that and front to rear directions by means of the
the fan blades move freely. adjustable legs.
7. Check that the compressor fits snugly onto
all its mounting pads. D. ELECTRICAL CONNECTIONS
8. See data plate on the rear side of the unit See data plate for current requirements to
and check that local main voltage corresponds determine wire size to be used for electrical
with the voltage specified on it. connections. All SIMAG icemakers require a
solid earth wire.
CAUTION. Incorrect voltage supplied to All SIMAG ice machines are supplied from the
the icemaker will void your parts factory completely pre-wired and require only
replacement program. electrical power connections to the wire cord
provided at the rear of the unit.
Page 2
Make sure that the ice machine is connected to installed in an accessible position between the
its own circuit and individually fused (see data water supply line and the unit.
plate for fuse size). If water contains a high level of impurities, it is
The maximum allowable voltage variation should advisable to consider the installation of an
not exceed -10% and +10% of the data plate appropriate water filter or conditioner.
rating. Low voltage can cause faulty functioning
and may be responsible for serious damage to
the overload switch and motor windings.
WATER SUPPLY - WATER COOLED MODELS
NOTE. All external wiring should conform to (SCN 75-125-215)
national, state and local standards and
regulations. The water cooled versions of SIMAG Ice Makers
require two separate inlet water supplies, one for
Check voltage on the line and the ice maker’s the water making the ice and the other for the
data plate before connecting the unit. water cooled condenser.
Connect the 3/4" GAS male fitting of the water
inlet, using the flexible tubing supplied with the
E. WATER SUPPLY AND DRAIN unit, to the cold water supply line with regular
CONNECTIONS plumbing fitting and a shut-off valve installed in
an accessible position between the water supply
GENERAL line and the unit.
WATER SUPPLY
NOTE. The water supply and the water drain
Connect the 3/4" GAS male of the water inlet
fitting, using the food grade flexible tubing supplied must be installed to conform with the local
with the machine, to the cold water supply line code. In some case a licensed plumber and/
with regular plumbing fitting and a shut-off valve or a plumbing permit is required.
Page 3
F. FINAL CHECK LIST 7. Have the bolts holding the compressor down
been checked to ensure that the compressor is
1. Is the unit in a room where ambient snugly fitted onto the mounting pads?
temperatures are within a minimum of 10 °C
(50°F) even in winter months? 8. Check all refrigerant lines and conduit lines
to guard against vibrations and possible failure.
2. Is there at least a 15 cm (6") clearance
around the unit for proper air circulation? 9. Have the bin liner and cabinet been wiped
clean?
3. Is the unit level? (IMPORTANT)
10. Has the owner/user been given the User
4. Have all the electrical and plumbing Manual and been instructed on the importance of
connections been made, and is the water supply periodic maintenance checks?
shut-off valve open?
11. Has the Manufacturer’s registration card been
5. Has the voltage been tested and checked filled in properly? Check for correct model and
against the data plate rating? serial number against the serial plate and mail
the registration card to the factory.
6. Has the water supply pressure been checked
to ensure a water pressure of at least 1 bar 12. Has the owner been given the name and the
(14 psi)? Open the shut-off valve and verify the phone number of the authorized SIMAG Service
absence of water losses from the connections. Agency serving him?
G. INSTALLATION PRACTICE
WARNING. This icemaker is not designed for outdoor installation and will not function in
ambient temperatures below 10°C (50°F) or above 40°C (100°F).
This icemaker will malfunction with water temperatures below 5 °C (40°F) or above 40 °C
(100°F).
Page 4
CONTACTOR COIL (SCN 75-125-215) NOTE. The wiring diagram shows the unit as
FAN MOTOR (only SCN 35) air cooled it is in the Evaporator Thermostat mode of the
WATER INLET SOLENOID VALVE Freezing Cycle.
HOT GAS SOLENOID VALVE
TIMER MOTOR
The incoming water, passing through the water BEGINNING FREEZE
inlet valve and in its incorporated flow control
(outlet), runs over the evaporator platen and then Electrical components (Loads) ....... ON OFF
flows by gravity through the dribbler holes down
Compressor ........................................ •
into the sump/reservoir.
The water filling the sump/reservoir forces part of Fan motor ........................................... •
the left-over water from the previous batch to run Hot gas valve ..................................... •
out to the waste through the overflow pipe. This Water inlet valve ................................. •
overflow limits the level of the sump water which Water pump ........................................ •
will be used to produce the next batch of ice Contactor coil ..................................... •
cubes. Timer motor ........................................ •
Meanwhile, the refrigerant as hot gas, discharged
from the compressor, flows through the hot gas Electric Controls .............................. ON OFF
valve directly into the evaporator serpentine by-
Conctats 3-4 evaporator thermostat .. •
passing the condenser.
The hot gas circulating into the serpentine of the Conctats 3-2 evaporator thermostat .. •
evaporator warms up the copper molds or the Bin thermostat .................................... •
tips causing the defrost of the ice cubes. The ice Conctats timer •
cubes, released from the molds, drop by gravity Conctats timer •
onto a slanted grid chute, then through a curtained Pressure control (SCN35÷45W) (SCN45÷SC215A) •
opening they fall into the storage bin.
At the end of the defrost cycle, both the hot gas
and the water inlet valves close and the machine TIMED FREEZE
starts again a new freezing cycle.
Electrical components (Loads) ....... ON OFF
Compressor ........................................ •
OPERATION - CONTROL SEQUENCE
Fan motor ........................................... • •
At the start of freezing cycle, the evaporator Hot gas valve ..................................... •
thermostat controls the length of the first part of Water inlet valve ................................. •
the freezing cycle. As its bulb senses a Water pump ........................................ •
predetermined temperature, it closes its contacts Contactor coil ..................................... •
to supply power to thetimer motor which, in turn,
takes over the control of the freezing cycle. Timer motor ........................................ •
This second part of the cycle has a pre-fixed time
duration of 12 minutes. Electric Controls .............................. ON OFF
. Conctats 3-4 evaporator thermostat .. •
Conctats 3-2 evaporator thermostat .. •
NOTE. The evaporator thermostat is factory Bin thermostat .................................... •
set to the number 4 of its setting dial. Conctats timer •
In case it is required the setting of the Conctats timer •
evaporator thermostat can be made by turning Pressure control (SCN35÷45W) (SCN45÷SC215A) • •
its adjusting screw located on front side.
With a clockwise rotation of the setting screw
the thermostat cut IN temperature will be I° PORTION HARVEST CYCLE
lowered (longer freezing cycle - thicker ice
cube) while, with a counterclockwise rotation Electrical components (Loads) ....... ON OFF
of the screw, the Cut IN temperature rises Compressor ........................................ •
(shorter freezing cycle - thiner ice cube). Fan motor (SCN 35 ON) .............. •
Hot gas valve ..................................... •
Once completed the freezing cycle 2nd phase Water inlet valve ................................. •
the system switches automatically into the defrost
cycle which has a pre-fixed length as well. Water pump ........................................ •
At completion of the defrost period the unit starts Contactor coil ..................................... •
again a new freezing cycle. Timer motor ........................................ •
Electric Controls .............................. ON OFF
OPERATION - ELECTRICAL SEQUENCE Conctats 3-4 evaporator thermostat .. •
Conctats 3-2 evaporator thermostat .. •
The following charts illustrate which switches Bin thermostat .................................... •
and which components are ON or OFF during a Conctats timer •
particular phase of the icemaking cycle. Conctats timer •
Refer to the wiring diagram for a reference.
Pressure control (SCN35÷45W) (SCN45÷SC215A) •
Page 8
II° PORTION HARVEST CYCLE After ice is removed from the bin and its bulb
warm-up it allows the unit to restart from the
Electrical components (Loads) ....... ON OFF beginning of the harvest cycle which, in the
Compressor ........................................ • circumstance, is more likely a water filling cycle.
Fan motor (SCN 35 ON) ............... •
Hot gas valve ..................................... • D. TIMER
Water inlet valve ................................. •
Equipped with two DIP switch and a Potentiometer.
Water pump ........................................ • it is located inside the control box.
Contactor coil ..................................... • .
Timer motor ........................................ • The function of the timer begins when activated
by the cube size control (evap. thermostat).
Electric Controls .............................. ON OFF The large diameter lobe of its cam determines
Conctats 3-4 evaporator thermostat .. • the 2nd freezing cycle portion length, while the
cam small diameter lobe, determines the time
Conctats 3-2 evaporator thermostat .. • cycle for the harvest sequence
Bin thermostat .................................... • Potentiometer used to adjust the defrost
Conctats timer • time from 60" min to 180" max.
Conctats timer •
Pressure control (SCN35÷45W) (SCN45÷SC215A) • •
WARNING. Never set the defrost time for
longer than 4 minutes as this will
jeopardize the compressor motor
windings.
OPERATING CHARACTERISTICS
On air cooled models during the freezing cycle It goes without saying that an extension of the
the discharge pressure is kept between 8 ÷10 defrost period will directly reduce the timed portion
bars (110÷140 psig) SCN35÷SCN75, 15,5÷20 bars of the freezing cycle and viceversa.
(215÷280 psig) SCN125-215. Consequently any variation made at the timer
At the same time the suction pressure will requires a compensation adjustment,
gradually decline, reaching its lowest point just very fine and very accurate, of the evaporator
before harvest. Compressor amps experience a thermostat.
similar drop.
E. COMPRESSOR ',3SWITCH
The compressor DIP switch is located on the Timer of
COMPONENTS DESCRIPTION the control box and it can be switched in two
different positions which are:
Operation Supply power directly to the
A. MASTER SWITCH compressor motor or, on models
Fitted on the front side of the unit cabinet the SCN75, SCN125 and SCN 215, directly
master switch has to be used to start-up and to to the contactor coil.
stop the ice maker operation. Cleaning Shuts-off the compressor so that
In connection with it there is the green monitor only the water pump and the water
light. inlet valve will remain in operation.
When positioned on “0 - OFF” the water pump
B. EVAPORATOR THERMOSTAT primes the cleaning or the bactericide solution
allover the unit water system to generate a good
The evaporator thermostat with its sensing bulb cleaning and sanitizing action of the ice maker.
intimately in contact with the refrigerant outlet
tube from the evaporator, senses the evaporating
refrigerant temperature (which declines in the NOTE. It is recommended to avoid the rinsing,
course of the freezing cycle) and when this one after the sanitation of the unit water system,
reaches the pre-set value, it switches its contacts as any bactericide coating, which is beneficial
from 3-4 to 3-2 to activate the finishing cycle (2nd to limit the bacteria growth, left-over in the
phase) which has a pre-set extension determined system may be removed.
by the large diameter lobe of the timer cam.
F. HI PRESSURE CONTROL
C. BIN THERMOSTAT
Used either on air (SCN45-SCN75-125-215A) and
The bin thermostat, which has its sensing bulb water (SCN35÷45W) cooled ice makers it
downward into the storage bin, shuts-OFF functions to maintain the head pressure within
automatically the icemaker when the ice storage the preset values of 8 ÷10 bars (110÷140 psig)
bin is filled and ice contacts its bulb. Being it SCN35÷SCN75, and 15,5÷20 bars (215÷280 psig)
connected in series with the front microswitch of SCN125-215, by intermittently activating the fan
the timer, it causes the unit shut-off only at the motor (in the air cooled models) and the water
end of the freezing cycle, when the ice cubes are inlet valve to the condenser (in the water cooled
completed. models SCN 35-45).
Page 9
SERVICE DIAGNOSIS
SYMPTOM POSSIBLE CAUSE SUGGESTED CORRECTION
Unit will not run Main switch in OFF position Turn switch to ON position
Shortage of water Water spilling out through curtain Check or replace curtain
SERVICE DIAGNOSIS
SYMPTOM POSSIBLE CAUSE SUGGESTED CORRECTION
Irregular cubes Some jets plugged Remove jet cover and clean
size & some cloudy
Shortage of water See shortage of water
Cubes too large Freezing cycle too long Adjust evap. thermostat
Capillary tube partially restricted Blow charge, add new gas & drier,
after evacuating system with
vacuu pump
Poor harvest Restriction in incoming water line Check water valve strainer and flow
control. If necessary enlarge the
flow control orifice
Water inlet valve not opening Valve coil with open winding
Replace valve
Hot gas valve orifice restricted Replace hot gas valve assy
Excessive water in unit base Water tubing leaking Check. Tighten or replace
Page 12
MAINTENANCE AND When remove the ice cubes from its sensing
bulb the unit will restart after few seconds from
CLEANING INSTRUCTIONS the defrost cycle assuring the filling up of the
water tank.
NOTE. Perform the above check only at the D. CLEANING INSTRUCTIONS OF WATER
beginning of the harvest cycle as, during the SYSTEM
freezing cycle the bin thermostat contacts
are bypassed by the front microswitch of the 1. Remove the front and the top panels to gain
timer. access either to the control box and to the
evaporator.
Page 13
2. Wait till the end of defrost cycle then, shut 8. Let the unit to remain in the CLEANING
the unit OFF by means of its master switch. mode for about 20 minutes then switch OFF the
machine.
3. Scoop out all the ice cubes stored into the
bin in order to prevent them from being 9. Flush out the cleaning solution from the
contaminated with the cleaning solution then sump reservoir then pour onto the evaporator
flush out the water from the sump reservoir by cavity one or two liters of clean potable water with
removing the overflow stand-pipe. the antibacteria solution P/N 26400002 to rinse
and sanitize the molds and the spray system.
4. Remove the plastic cup located on the If necessary remove the spary bar and nozzles to
bottom of sump/freezing chamber to drain out all
water and scale deposits. clean them separately then refit them.
7. Set the compressor switch on "0 - OFF" 15. Wipe clean and rinse the inner surfaces of
position and give power to the unit by the master the storage bin.
switch (Fig.6).
REMEMBER. To prevent the accumulation
NOTE. With the system inCLEANING mode of undesirable bacteria it is necessary to
the water pump is the only component in sanitize the interior of the storage binwith
operation to circulate the cleaning solution in an anti-algae disinfectant solution every
the entire water system. week.
I C E M A C H I N E S
www.simag.it