Software Version Description

Programming System SIPLACE Pro V5.0

Edition 05/2007 US
UNIX is a registered trademark of AT&T
X-Windows is a trademark

LINUX is a trademark
Microsoft and MS-DOS are registered trademarks of Microsoft Corporation
Microsoft Windows is registered trademark of Microsoft Corporation

(The reproduction, transmission or use of this document or its contents is not permitted (We have checked the contents of the printed documentation to ensure that is in
without express written authority. agreement with the hardware and software described therein. However, since discre-
Offenders will be liable for damages. All rights, including rights created by patent grant or pancies cannot be ruled out, we cannot assume responsibility for complete agreement.
registration of a utility model or design, are reserved.) the information given in this printed documentation is however regulary reviewed and
necessary corrections included in subsequent editions. We would appreciate any
suggestions for improvements.)

Siemens AG 2007 All rights reserved Subject to change without prior notice

Item-No.: 00195358-01 Siemens AG

To be ordered from

SIEMENS AG, Automation and Drives


Electronics Assembly Systems
Rupert-Mayer-Strasse 4
D-81359 Munich / Germany

Printed in the Federal Republic of Germany

UNIX ist ein Warenzeichen von AT&T


X-Windows ist ein Warenzeichen
LINUX ist ein Warenzeichen
Microsoft und MS-DOS sind eingetragene Warenzeichen von Microsoft Corporation
Microsoft Windows ist ein eingetragenes Warenzeichen von Microsoft Corporation

(Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und Mitteilung ihres (Wir haben den Inhalt der Druckschrift auf Übereinstimmung mit der beschriebenen
Inhalts sind nicht gestattet, soweit nicht ausdrücklich zugestanden. Hard- und Software geprüft. Dennoch können Abweichungen nicht ausgeschlossen
Zuwiderhandlungen verpflichten zu Schadenersatz. Alle Rechte vorbehalten, insbe- werden, so dass wir für die vollständige Übereinstimmung keine Gewähr übernehmen.
sondere für den Fall der Patenterteilung oder GM-Eintragung.) Die Angaben in dieser Druckschrift werden jedoch regelmäßig überprüft und notwendi-
ge Korrekturen sind in den nachfolgenden Auflagen enthalten. Für Verbesserungsvor-
schläge sind wir dankbar.)

Siemens AG 2007 All rights reserved Technische Änderungen vorbehalten

Artikel-Nr.: 00195480-01 Siemens AG

Bestellung an:

SIEMENS AG, Automation and Drives


Electronics Assembly Systems
Rupert-Mayer-Strasse 44
D-81359 München

Printed in the Federal Republic of Germany

2- 72
Programming System SIPLACE Pro Software Version Description

Contents
Page

INTRODUCTION 8

1 SCOPE OF DELIVERY 9

1.1 Packages 9

1.1.1 Basic documents 10

1.1.2 Detailed installation manuals 10

1.2 Available Languages 11

2 FEATURES SIPLACE PRO 5.0 12

2.1 Features in combination with Station Software 604 12

2.1.1 Support of SIPLACE Machines with Station Software 604 12

2.1.2 Higher placement performance of C&P20 heads of X series 12

2.1.3 Increased Machine Performance due to Reduced Board Clamping during Transport 12

2.1.4 01005 Placement for X Series and D Series 12

2.1.5 New Dip Module for X Series 13

2.1.6 Intelligent S Feeder with Automatic Pitch Download 13

2.1.7 Shutterless S Feeder (3 x 8 mm SL) 14

2.1.8 Licensing Setup Center 14

2.1.9 Coplanarity Tolerances in Component Shape Editor 14

2.1.10 3-Support of Optical Inspection Systems of SIPLACE OS Family 15

2.2 General Improvements in SIPLACE Pro Desk 15

2.2.1 Redesign Lead Groups in Component Shape Editor 15

2.2.2 New Functions in ASCII Centroid Wizard 15

2.2.3 Simple Alignment of a Graphic behind a Board in the Board Editor 16

2.2.4 Show and Hide Individual Panels on a Board 17


3 - 72
Software Version Description Programming System SIPLACE Pro

2.3 Optimizer Features 17

2.3.1 Identical Nozzlee Configuration for C&P Heads for all Recipes in a Job 17

2.3.2 Avoid Redistributing Components on Placement Heads 18

2.3.3 Save Optimizer SPOT Files in a Separate Default Folder 19

2.4 Features of LC GUI 19

2.4.1 Flexible Setup Management 19

2.4.2 Download of Partial Setups 20

2.5 Support of SOKOs/special design constructions 21

2.5.1 Support of SOKO/special design construction for Traceability 407 21

3 ESTABLISHED FEATURES 23

4 REQUIREMENTS 25

4.1 SIPLACE Pro Server 25

4.1.1 Recommended Hardware 25

4.1.2 Required Software 25

4.1.3 File Transfer Utilities 26

4.2 SIPLACE Pro Client 27

4.3 SIPLACE Stand Alone Configuration 28

4.4 Supported Databases 28

4.5 External Software 29

4.6 Interfaces to other Siemens Products 29

4.7 Interfaces to other SIPLACE Pro Versions 29

4.8 SIPLACE Pro Interface (SPI) 29

4.9 Resource requirements 31

4- 72
Software Version Description Programming System SIPLACE Pro

5 LIMITATIONS 32

5.1 Restrictions 32

5.2 Known Issues/Problems (General) 33

5.2.1 Installation 33

5.2.2 Placement Machine 33

5.2.3 Station-wise Download 33

5.2.4 Export restrictions from SIPLACE Pro to the Line Computer 34

5.2.5 Miscellaneous 35

5.3 Troubleshooting 36

5.3.1 Error Reporting Tool 36

5.3.2 Creating a SPOT file 36

5.3.3 Troubleshooting if a system feature is not usable after installation 38

6 NOTES 40

6.1 Preparation for Installation 40

6.2 Nozzles 41

6.2.1 9xx Nozzles on the Twin Head 41

6.2.2 Meaning of the nozzle parameters and recommended values for the 9xx nozzles as
5xx nozzles on the Twin Head 41

6.3 Component Shape 43

6.4 Printing Reports 43

6.5 Backup of System Feeder Inventory 43

7 CORRECTED DEFECTS (FROM SISCOPE) 44

APPENDIX A: SUPPORTED HARDWARE 46

5 - 72
Software Version Description Programming System SIPLACE Pro

Norms and Standards 46

Supported Stations 47

Supported Nozzles 47

Supported Nozzle Changers 48

Supported Feeder Modules 48

Allocation of Feeder Types to Station Types (1/2) 49

Allocation of Feeder Types to Station Software Version (1/4) Station Software 604 – 504 52

Allocation of Feeder Types to Station Software Version (2/4) Station Software 503 – 101 53

Allocation of Feeder Types to Station Software Version (3/4) 54

Allocation of Feeder Types to Station Software Version (4/4) Station Software 503 – 101 55

Supported Table Types 56

Supported Vision Systems 58

Supported Sensor Modules (1/2) Station Software 604 – 504 58

Supported Sensor Modules (2/2) Station Software 503 - 101 59

APPENDIX B: SHARED INTERFACES 60

Line Computer UNIX 60

APPENDIX C: PLATFORM – STATION SOFTWARE – MACHINE 61

APPENDIX D: DATA COLLECTION POLICY 63

APPENDIX E: ACCELERATION DATA 66

APPENDIX F: OVERVIEW VISION SYSTEMS 70


6- 72
Software Version Description Programming System SIPLACE Pro

7 - 72
Software Version Description Programming System SIPLACE Pro

Introduction
SIPLACE Pro is a programming system for SIPLACE placement machines. SIPLACE Pro is a Windows-
based application.

The SIPLACE Pro package consists of the following functional modules:

• SIPLACE Pro Server


• SIPLACE Pro Database
• SIPLACE Pro Desk (client)
• Line Control Server
• Line Control GUI (client)

SIPLACE Pro uses a database (Microsoft SQL Server) to store the customer data. All Clients (e.g. SIPLACE
Pro Desk) communicate with the database via SIPLACE Pro Server. The SIPLACE Pro API (Application
Programming Interface) enables access to database objects via COM and NET interfaces.

SIPLACE Pro 5.0 version supports any machines of platform I, II and platform II+ . Platform II+ machines
consist of the SIPLACE X series plus the SIPLACE D series machines. You find a more detailed overview of
the machines and the respective station software in Appendix C: Platform – Station Software – Machine.

8- 72
Software Version Description Programming System SIPLACE Pro

1 Scope of Delivery

1.1 Packages
The Basic Software Package SIPLACE Pro 5.0 (Item No. 00116672-xx) consists of the following:

CDs:
• 1 CD-ROM “SIPLACE Pro”, which contains
→ SIPLACE Pro 5.0

• 1 SIPLACE Pro Factory License (without the connection to SIPLACE stations)


• 1 CD-ROM with OIS 5.0 Server and Client
• 1 DVD Suppot Media

The Upgrade Software Package SIPLACE Pro 5.0 (Item No. 00385400-xx) contains the necessary
components for an upgrade from 1.x Service Packs, 2.x Service Packs and 3.x Service Packs, 4.x to
SIPLACE Pro 5.0

• 1 CD-ROM “SIPLACE Pro”, which contains


→ SIPLACE Pro 5.0

• 1 CD-ROM with OIS 5.0 Server and Client


• 1 DVD Support Media

9 - 72
Software Version Description Programming System SIPLACE Pro

1.1.1 Basic documents


• Getting Started with SIPLACE Pro 5.0
(English: Item No. 00195481-01, German: Item No. 00195482-01)
• Software Version Description SIPLACE Pro 5.0
(English: Item No. 00195480-01, German: Item No 00195479-01)
• Installation of SIPLACE Pro 5.0 (English: Item No 00195483-01)

1.1.2 Detailed installation manuals


• Configurations for SIPLACE Pro (English: Item No 00193760-06)
• Guideline for XML Import / Export (English: Item no. 00193789-05)
• Standard Component Shape Library Handling (English: Item no. 00194625-02)
• Software Version Description SIPLACE CAD V4.1 (English: Item no. 00194678-03)

Note:
Please use the document “Navigation Guide for the Installation Procedure of SIPLACE
Software Systems” (Item No. 00195050-xx) to navigate through the documentation. The
navigation guide and all related documents are available on the Support Media DVD (Item No.
00383100-xx) that is attached to every software product.

10- 72
Software Version Description Programming System SIPLACE Pro

1.2 Available Languages


For SIPLACE Pro 5.0 the Graphical User Interface (GUI) is available in following languages.

Standard GUI SIPLACE Pro:


- English
- German
Language Pack SIPLACE Pro:
- French
- Italian
- Spanish
- Portuguese
- Hungarian
- Czech
- Russian
- Turkish
- Polish
- Estonian
- Korean
- Chinese Traditional
- Chinese Simplified
- Japanese

Note:
The following languages – Polish, Estonian, Russian and Turkish – contain a language specific
GUI and an English online help.

Note:
The new application Optimizer GUI as well as the Optimizer Messages online help available in
English and German only.

11 - 72
Software Version Description Programming System SIPLACE Pro

2 Features SIPLACE Pro 5.0

2.1 Features in combination with Station Software 604

2.1.1 Support of SIPLACE Machines with Station Software 604


SIPLACE Pro 5.0 supports the SIPLACE machine types running with station software 604
You find a more detailed list in Appendix C: Platform – Station Software – Machine.

2.1.2 Higher placement performance of C&P20 heads of X series


With station software 604 the placement performance of C&P20 Heads of the X Series machine types
increases. This means for example for an X4 with four C&P20 Heads an increased placement performance
from 80,000 to 90,000 cph. But this performance increase is only working together with the new hardware
components (axis card A364, …).

2.1.3 Increased Machine Performance due to Reduced Board Clamping during Transport
In SIPLACE Pro 5.0 you can edit in the line editor the transport space from 0 – 40 mm. This means the
board is transported as soon as the transport space has entered the reached value.
For stations with station software 40x/50x the default value is 40 mm. For stations with station software 601 –
603 the default vaules are 40 mm or 20 mm.

2.1.4 01005 Placement for X Series and D Series


SIPLACE Pro 5.0 enables 01005 placement for the X series and D series. For successful 01005 placement
you have to mark the check box in the component shape editor.
For 01005 placement following hardware and software requirements are essential. In addition, for the
nozzles special segments are required for the C&P heads.

01005 Placement
X series D series
Station X1, X2, X3, X4 D2, D4
Station computer 602, 603 604
software
Nozzles 1005 (for C&P20 head of X series) 905 (für C&P12 Kopf der D-Serie)
Camera SST 23 (for C&P20 head) SST 38 (für C&P12 Kopf)
Feeder 3x8 mm S 01005, 3x8 mm S 01005,
8 mm X 8 mm X
Component 96, 97 96, 97
shapee
Travel profile 33 – Place Down 01005 Component 33 – Place Down 01005 Component
34 - Place Down 01005 Component Slow 34 - Place Down 01005 Component Slow
35 – Pickup Down Contactless 01005 35 – Pickup Down Contactless 01005

12- 72
Software Version Description Programming System SIPLACE Pro

Note:
In SIPLACE Pro the component shapes 96 and 97 are pre-configurated for 01005 placement.

2.1.5 New Dip Module for X Series


The new dip module “Linear Dipping Unit X” is running on all X series stations with station software 604.
The new dip module has to be setup manually on the new changeover table and is only running on X tables
with station software 604.
Please consider following restrictions when using the dip module:
• For each placement head SIPLACE Pro allows only one dip module..
• The user has to setup the dip module manually. The optimizer does the setup of the dipped
component automatically.
• SIPLACE Pro does not check the geometry of the component in the dipping area.
• And it is not checked if the placement head can reach the dip module.
• The download provides dummy data for the dip module.

The following table shows which heads and tables are compatible to the new dip module LDU_X:
Twin head C&P 6/12 C&P20 P&P

X series(S feeder) No No No -

X-series (X feeder) Yes Yes No -

D series - No - No

2.1.6 Intelligent S Feeder with Automatic Pitch Download


In SIPLACE Pro 5.0 the user must not set the pitch of the S feeder manually at the feeder. This is done
automatically by the pitch download. You simply have to activate in Line Control GUI the option “Overwrite
Feeder Information on each Download”.
Thus for all X and S feeders the pitch is set for all components or component shapes in the component or
component shape editor. For all feeder types equipped with this special component the same pitch is valid.
Please consider following restrictions:
• Surftape feeder are not supported.
• No check of the current pitch. The pitch is only set when downloading. If the feeder is exchanged
later on the new feeder is not provided with the updated pitch from SIPLACE Pro.
• For each placement head SIPLACE Pro allows only one dip module..

13 - 72
Software Version Description Programming System SIPLACE Pro

• The user has to setup the dip module manually. The optimizer sets the dipped component
automatically.
• A manual pitch change at the feeder is not recognized by the station.
• All feeders that support the pitch download have a different version number. You find more detailed
information in the version description of station software 604.

2.1.7 Shutterless S Feeder (3 x 8 mm SL)


SIPLACE Pro 5.0 supports a new tape feeder – Shutterless-S Feeder 3 x 8 mm SL. The new feeder type is
similar to the 3 x 8 mm S feeder except for the two new pickup positions. These pickup positions are shifted
backwards by 4 mm in direction of the y-axis. The Shutterless Feeder is useable on all S tables.
The Shutterless-Feeder can be setup on the following machines.
Station software Machine type
604 D1, D2, D3, D4
X2, X3, X4
505 S-25HM, S-27HM, HS-50,
HS-50+, HS-60, HF, HF/3

Note:
Station software 505 and 604 support the Shutterless-Feeder. For station software 505 the
user must make sure that the station software 505.04 SP1 is installed on all PII stations..

2.1.8 Licensing Setup Center


SIPLACE Pro 5.0 checks the different licenses for Setup Center:
- Check if license for Setup Center forced verification with station software 40x and 50x.
- Check if license for Setup Center forced verificationl with station software 60x and higher.
There are 3 license keys that can be entered in SIPLACE Pro License Manager for Setup Center. The
SIPLACE Setup Center is always used.

2.1.9 Coplanarity Tolerances in Component Shape Editor


SIPLACE Pro enables the component shape editor to activate following two features of the 3D coplanarity.
Make sure that you choose before the function “Coplanarity”.
- Tolerance of coplanarity measurement: gives the maximum permissible deviation between the
calculated coplanarity level and the lead which is furthest away.
- Placement even if the measurement fails

14- 72
Software Version Description Programming System SIPLACE Pro

For more details please refer to the online help.

2.1.10 3-Support of Optical Inspection Systems of SIPLACE OS Family


In SIPLACE Pro 5.0 it is possible to provide board data for the optical inspection systems during a download.
For each line a shared network directory can be configured. In that directory all board data are copied during
a download. The operator only has to import the provided board data in the optical inspection system. The
board data are available as .qd file. The file name for the provided board data in the line computer (qd file) is
formed as follows: “<board name_<conveyor lane number>.qd“
In order to have access to the network directory a user account has to be configured. Normally, this is a local
user account on the computer for the optical inspection system (domain field is empty). Alternatively, you can
also configure a domain user account for a network directory on a different computer.
For more detailed information on the configuration please refer to the online help.

2.2 General Improvements in SIPLACE Pro Desk

2.2.1 Redesign Lead Groups in Component Shape Editor


From SIPLACE Pro 5.0 on, in the component shape editor the lead groups are clearly arranged (new
functions: rename and sort).

(rename) renames the lead groups

(sort by name) sorts the lead groups by name in the list view

(sort by lead type) sorts the lead groups by type in the list view

2.2.2 New Functions in ASCII Centroid Wizard


In the ASCII Centroid Wizard (Step 3) of SIPLACE Pro 5.0 there is a new column „Transparent“. In case
there is a column available with the identification 0/1 (0 = not transparent, 1 = transparent), the user can
assign the designation „Transparent“ to this column. This makes it possible to show individual components
transparently.

15 - 72
Software Version Description Programming System SIPLACE Pro

2.2.3 Simple Alignment of a Graphic behind a Board in the Board Editor


In the board editor of SIPLACE Pro it is possible to align a graphic (bmp, jpg, gif) in a much simpler way
behind a board. You just have to define two pairs of points (board and graphic). For more detailed
information please refer to the online help.

16- 72
Software Version Description Programming System SIPLACE Pro

2.2.4 Show and Hide Individual Panels on a Board


It is not only possible to hide and show placement positions of complete boards but also to hide and show
single panels. This setting is only locally visible in the board editor and it is not saved. The optimizer
considers all boards and does not consider if these panels are shown or hidden.

Note:
Panels from the 3rd level (main level = level 0) can not be shown or hidden..

2.3 Optimizer Features

2.3.1 Identical Nozzlee Configuration for C&P Heads for all Recipes in a Job
In SIPLACE Pro 5.0 there is a new option (Generate identical C&P head nozzle configuration for all recipes)
in the optimizer parameters. This option enables the same nozzle configuration (fixed setup) on the C&P
heads for all recipes of a job. This configuration avoids a nozzle change if several recipes have to be placed
in a job.

Note:
This function is also valid for the special segments required for 01005 placement of the D
series. The segments do not have to be changed for every recipe.

17 - 72
Software Version Description Programming System SIPLACE Pro

Results in the Setup of “Identical Nozzle Configuration

2.3.2 Avoid Redistributing Components on Placement Heads


In SIPLACE Pro 5.0 there is the new option „Do not change placement sequence“. This option can only be
activated in optimizer level 2 and in expert mode. This new option is an addition to the already existing option
“Avoid redistributing placement positions for each head”.
This new option avoids redistributing the placement positions for each head. And in this additional option the
placement sequence during optimization remains the same.
Activate this function if you have already achieved an optimal production during successful optimization but
you need to optimize again. The optimization results you have already achieved for the production time
remain the same after a new optimization.

18- 72
Software Version Description Programming System SIPLACE Pro

Parameter dialogue with the new option in OL2

2.3.3 Save Optimizer SPOT Files in a Separate Default Folder


In SIPLACE Pro 5.0 the SPOT files created by the optimizer are saved in a default folder SPOT or in a
different user-specifc folder. For more details please refer to the online help and chapter 5.3.2. Creating a
SPOT file.

2.4 Features of LC GUI

2.4.1 Flexible Setup Management


In the LC GUI of SIPLACE Pro 5.0 it is possible to choose the recipes to be produced and to deliver the
necessary information which recipes are produced when and in which job or production schedule. For
activation of the flexible setup management you have to mark the checkbox “Permit selection of the recipes
to be produced next” first. After that the operator can mark the individual recipes in the LC GUI or an external
application (via SPI) can mark them. For more details please refer to the online help.

enables the next recipe to be produced from the currrent job/production schedule list.

disables the marked recipe in the current job/production schedule list.

switches over to a second job/production schedule for the same line in which recipes are also marked
for production.
This is valid for the download of production schedules or jobs (barcode mode).

19 - 72
Software Version Description Programming System SIPLACE Pro

2.4.2 Download of Partial Setups


SIPLACE Pro 5.0 enables a download of partial setups. First of all you have to activate the download of
partial setups via Configuration -> Download -> Partial Setup. The setups which are sent to the stations
contain only those components which are needed for the selected recipes. The recipe selection can be done
manually or refers automatically to the downloaded recipe. For more details please refer to the online help.
Restrictions:
- Asynchronous dual conveyor: If a recipe is being downloaded to a conveyor lane and the same or
another recipe has already been downloaded to the other lane in dual asynchronous mode, there
can be a conflict if the filtered partial setups differ. In order to solve this conflict you have to
download the recipes for both conveyor lanes. The option “Avoid redistributing components” avoids
that the line is completely emptied.
- The barcode mode supports the manual recipe selection only since the line control does not know
which board type is currently in the line.
- If in barcode mode the manual recipe selection is changed there can be a conflict that the filtered
partial setup changes. All active recipes have to refer in barcode mode to the same filtered partial
setup. In order to solve this conflict all active recipes have to be downloaded together. The option
“Avoid redistribution of components” avoids that the line is completely emptied.

enables and disables the download of partial setup for the marked line/recipe. These icons are only
possible during manual recipe selection.

switches over to another recipe to be produced (job or production schedule).

20- 72
Software Version Description Programming System SIPLACE Pro

2.5 Support of SOKOs/special design constructions

2.5.1 Support of SOKO/special design construction for Traceability 407


SIPLACE Pro 3.2 SP1, SIPLACE Pro 4.1SP1 and SIPLACE Pro 5.0 support the SOKO for Traceability 407
and have implemented a solution to automatically transfer the data to stations with 407 station software. This
solution requires some minor changes on the station computer, which are described in this chapter.
Note
Please note that this feature has only been implemented in SIPLACE Pro 3.2 SP1, SIPLACE
Pro 4.1SP1 and SIPLACE Pro 5.0.

To activate this SOKO, the following steps are necessary in SIPLACE Pro:
1. In the station editor for each station with software version 407, activate the checkbox “Supports
Traceability SOKO 407.”
2. For each component that should be traced, open the appropriate component and activate the
checkboxes for “Validate” and then also for “Trace”.
3. Verify that each Component and associated Component Shape has a Feeder pitch for each feeder
in the list.

On the station, Traceability should already be activated with the appropriate CD. Log in as Administrator and
make the following changes:
1. Configure the share for the folder C:\SRDaten. To do this,
a. right click on the folder and choose Sharing and Security.
b. Select the radio-button “Share this folder” and note that the name “SRDaten” is automatically
entered in the field. This is correct.

2. Now click on the button “Permissions” and verify that “everyone” has “Full Control”. If this isn’t the
case, change the permissions for “Everyone”.

21 - 72
Software Version Description Programming System SIPLACE Pro

3. Return to the Permissions window and switch to the Security tab. Choose Advanced. In the new
window that opens make sure the checkbox “Inherit from parent the permission entries that apply
to child objects. Include these with entries explicitly defined here” is selected.

4. Close all windows and reboot the station.

After the station has rebooted, you can perfom a download. The Traceability data is saved in the folder
C:\SRDaten\SrcMa to a file called TraceBE.dat. This file is read automatically when you choose to configure
the Trace parameters via the station software.

22- 72
Software Version Description Programming System SIPLACE Pro

3 Established Features
SIPLACE Pro Desk, the client portion of SIPLACE Pro, eases the task of programming SIPLACE machines
by providing a graphical user interface. It provides the following features:

Editors
Editors enable you to create, edit, and delete SIPLACE Pro information with complete access to system
resources. SIPLACE Pro Desk offers the following:

• Component Shape Editor


• Component Editor
• Board Editor
• Placement List Editor (part of Board Editor)
• Station Editor
• Line Editor
• Setup Editor
• Table Editor
• Job Editor
• Recipe Editor
• Waffle Pack Tray Editor
• Fiducial Editor
• Custom Nozzle Editor
• Restriction Editor
• Feeder Inventory Editor
• Precedence Editor (part of Board Editor)

In addition, SIPLACE Pro Desk offers the following features:

• Optimization
• Barcode Manager
• Line Control GUI (for downloading placement programs - recipes - to a line)
• Vision Data Manager (for managing vision data)
• Job Mixer (in conjunction with synchronous dual conveyor and PCB Barcode Operation)
• Security (Tools –> Administration –> User Database -> User Groups -> Privileges & Permissions)
• Information “Where Used?” for linked objects.
• Lock SIPLACE Pro Desk
• SICluster Optimizer (optional)
• Setup Modification Generator
• Query Tool
• Gerber Data Converter
• Find Component Shapes

23 - 72
Software Version Description Programming System SIPLACE Pro

• SIPLACE Pro Multi Job Optimization (SIPLACE Pro Optimizer)

Wizards
Wizards simplify complicated tasks by providing a structured environment. SIPLACE Pro Desk offers the
following:

• ASCII Centroid Data Import Wizard


• CAD Data Import Wizard (available as an option)
• Component Shape Wizard
• Difference Editor Wizard (allows user to compare components, component shapes, placement lists and
fiducials)
• Data Model Import / Export Wizard (XML)
• Line Computer Import Wizard
• Line Computer Export Wizard
• Standard Shape Library and Fiducial Import Wizard
• SiCluster Job Wizard (available as an option)

24- 72
Software Version Description Programming System SIPLACE Pro

4 Requirements
SIPLACE Pro 5.0 is usable on a standard PC with Windows XP SP2 or Windows 2003 Server (optional with
SP1) and optionally with a Multilanguage Pack. The requirements are for SIPLACE Pro software only.
You find more details about recommended norms and standards in Appendix A: Norms and Standards.

Note:
SIPLACE Pro requires an NTFS partition to be installed on. FAT or FAT32 file systems are not
supported.

4.1 SIPLACE Pro Server

4.1.1 Recommended Hardware


The following Hardware is recommended for the SIPLACE Pro Server:
• Pentium 4 with 3.0 GHz or higher
• 2 x 160 GB hard disk
• 2048 MB memory (1024 MB min.), depends on the complexity of the data content
• Optional Backup drive (e.g. DAT, DVD-writer)
• 21’’ screen, min. 19” screen (CRT)
• optional SR-UPS

4.1.2 Required Software


The following Software is required:
• Windows 2003 Server Standard Edition with SP1 and SQL 2000 with SP4 / SQL 2005 mit SP1, or
• Windows XP Professional with SP2 and MSDE with SP4 / SQL 2005 Express SP1

Note:
Windows Server 2000/W2K is not longer supported. This means that SIPLACE Pro is not
compatible to Windows 2000/W2K. Therefore please make sure that you upgrade your Windows
Server 2000/W2K system to Windows 2003/Windows SP.

Note:
SIPLACE Pro requires Microsoft ®.NET Framework 1.1, 1.1 SP1 and 2.0. If the setup program
does not find the Microsoft ®.NET Framework 2.0, the user is asked to install the framework
right from the product CD. If you decide to use the .Net Framework 1.1 SP1 or 2.0, you should
carefully test other applications on your computer for compatibility with this version of the
Framework.
Note:
A hard disk with 500 MB or more free space should be used for installation.

25 - 72
Software Version Description Programming System SIPLACE Pro

4.1.3 File Transfer Utilities


For File Transfer between SIPLACE Pro (Windows XP/Windows 2003) computer and the Line Computer
UNIX via network the following Software Tool is recommended:

• SAMBA (item no 00191969-01): This is part of the LCU distribution disk since version 502.01
• Instead of SAMBA, either DiskAccess or HummingBird may be used as an NFS client.
However, these tools have to be configured and procured by customers themselves.

26- 72
Software Version Description Programming System SIPLACE Pro

4.2 SIPLACE Pro Client


The following Hardware is recommended for the SIPLACE Pro Client:
• Pentium 4 with 3.0 GHz (Minimum: Pentium III 1 GHz)
• 80 GB hard disk
• 1024 MB memory (min. 512 MB), depends on the complexity of the data content
• 21“ screen (CRT), 19“ min. with a screen resolution of 1024 x 768 pixel at minimum (small fonts)

Note:
The XML Import/Export feature is limited to a file size of 50 MB (this corresponds
approximately to an optimized job with 7 boards with 1500 placement positions for the top
and the bottom). But this limit is already exceeded with a central memory of 512 MB. For
this reason we recommend to increase the central memory of the SIPLACE Pro Client
System to 1 GB when using XML ImportExport.

Note:
Make sure that all dialogs and editors are completely readable and displayed on the
screen by using “small fonts” (Settings –> Control Panel –> Display –> Appearance -
Advanced –> Small Fonts).

The following Software is recommended:


• Windows XP Professional with SP2 and MSDE 2000 with SP4/SQL 2005 Express

Note:
SIPLACE Pro requires Microsoft ®.NET Framework 1.1 SP1 and 2.0. If the setup
program does not find the Microsoft ®.NET Framework 2.0, the user is asked to install
the framework right from the product CD. If you decide to use the .Net Framework 1.1,
1.1 SP1 or 2.0, you should carefully test other applications on your computer for
compatibility with this version of the Framework.
Note:
A hard disk with 500 MB or more free space should be used for installation.

Note:
If the SIPLACE Pro server is also used as SIPLACE Pro client, make sure that you use a
21” monitor.

27 - 72
Software Version Description Programming System SIPLACE Pro

4.3 SIPLACE Stand Alone Configuration


The following Hardware is recommended for the SIPLACE stand alone configuration:
• Pentium 4 with 3,0 GHz or higher
• 2 x 160 GB hard disk
• 2048 MB memory (1024 MB min.)
• Backup drive (e.g. DAT, DVD)
• 21’’ screen, min. 19” screen
• optional SR-UPS

The following Software is required:


• Windows XP Professional with SP2 and MSDE 2000 with SP4/SQL 2005 Express

Note:
SIPLACE Pro requires Microsoft ®.NET Framework 1.1 SP1 and 2.0. If the setup
program does not find the Microsoft ®.NET Framework 2.0, the user is asked to install
the framework right from the product CD. If you decide to use the .Net Framework 1.1
SP1 and 2.0, you should carefully test other applications on your computer for
compatibility with this version of the Framework.

4.4 Supported Databases


Supported Databases are:
ƒ Microsoft SQL Server 2000 with SP4
ƒ Microsoft SQL Server 2000 Desktop Engine (MSDE) with SP4
ƒ Microsoft SQL Server 2005 SP1
ƒ Microsoft SQL Server 2005 Express SP1

One of the listed databases is a precondition for a successful SIPLACE Pro installation.

Note:
For more details on the XML Import/ Export please refer to the document “Guideline for XML
Import / Export “ (English: Item No. 00193789-05).
Note:
All available user databases of SIPLACE Pro release versions are automatically upgraded
during installation to SIPLACE Pro 5.0 data format. You could also import all XML files of all
previous versions (from SIPLACE Pro 2.0).

28- 72
Software Version Description Programming System SIPLACE Pro

4.5 External Software


SIPLACE Pro 5.0 uses Developer Studio 2005 and requires .NET Framework 2.0.
Note:
The setup program checks for .NET Framwork 2.0 but does not automatically install it. If it is
missing the user gets an error message which asks him to install the framework from the
Support Media DVD..

4.6 Interfaces to other Siemens Products


SIPLACE Pro 5.0 supports following Siemens Products:
Siemens products SIPLACE Pro 5.0 SIPLACE Pro 4.1

SIPLACE OIS/SIS Version 4.0 Version 4.1


SIPLACE SiCluster X X
SIPLACE UNIX/LINUX Line Computer 402.01 – 503.xx 402.01 – 503.xx
SIPLACE Explorer Version 2.2 Version 2.1
SIPLACE EDM Version 1.4 Version 1.3
SIPLACE Line Server Version 2.2
SIPLACE CAD Version 4.1 Version 4.1

X with application; if available version is listed


- without application

SIPLACE Pro 5.0 unterstützt die Stationssoftware-Versionen:


• 101, 407, 408
• 502, 503, 504, 505
• 601, 602, 603, 604

4.7 Interfaces to other SIPLACE Pro Versions


SIPLACE Pro 5.0 is compatible to SIPLACE Pro 1.x, 2.x, 3.x, 4.x including all Service Packs. This means all
released SIPLACE Pro versions except SIPLACE C Pro versions can be upgraded to SIPLACE Pro 5.0.

4.8 SIPLACE Pro Interface (SPI)


In order to be with SIPLACE Pro state-of-the-art, SIPLACE Pro 4.1 and all following versions will release the
new public interface SPI.NET that bases on the .NET technology. SPI.NET is used for many internal and
external applications as open interface for SIPLACE Pro objects and data.

29 - 72
Software Version Description Programming System SIPLACE Pro

For all SIPLACE Pro versions 2.x/3.x, SPI.COM is the currently used interface for SIPLACE Pro. SPI.COM is
used for many internal and external applications as public interface for SIPLACE Pro objects and data.
SPI.COM is the currently released public interface that bases on the COM technology. SPI.COM will be
supported until SIPLACE Pro V 4.1 including all service packs.
For more details on our Interface for Third Party Software please refer to www.SIPLACE.com see Products &
Solutions -> SIPLACE Software Suite -> Interface Support.

30- 72
Software Version Description Programming System SIPLACE Pro

4.9 Resource requirements


Harddisk
Windows & Program Files = 3000 MB
Database and Backup = Number of optimized recipes x 15 MB

Main Memory
Windows = 100 MB
SQL Server = 150 MB

LCS = 100 MB
LC GUI = 60 MB + Number of Recipes x Number of
Placements / 1000 MB

Desk = 60 MB + Number of Recipes x Number of


Placements / 1000 MB
Memory Requirements - Example a:
ECONEL 30 with complete SIPLACE Pro installation (stand alone) and the following characteristics:
• 500 optimized recipes in the system
• Jobs with approx. 7 recipes with 1000 placement positions on each PCB
• In SIPLACE Pro Desk one job is open.
• In the LC GUI there is one production plan open with maximum 7 recipes.

Harddisk (min. size) => ~ 10 GB


Main Memory (min. size) => ~ 490 MB

Memory Requirements - Example b:


ECONEL 30 with complete SIPLACE Pro installation (stand alone) and the following characteristics:

• 1000 optimized recipes in the system


• Jobs with approx. 10 recipes with 2000 placement positions on each PCB
• In SIPLACE Pro Desk one job is open.
• In the LC GUI there is one production plan open with maximum 20 recipes.

Harddisk (min. size) => ~ 18 GB


Main Memory (min. size) => ~ 850 MB

31 - 72
Software Version Description Programming System SIPLACE Pro

5 Limitations
In this section, we discuss system limitations. We will list all restricted features.
Note:
On Windows 2003 Server users without administration rights cannot use the bug report, as
long as they are not assigned to the local user group "Performance Counter Users".

5.1 Restrictions
• Complete LCU import of customer data may occur slowly (up to several hours), depending on the amount
of data.
• Linear 10 and 15 reserves cannot be combined on the same Linear Feeder Module.
• When using bitmaps for boards to verify component placements and rotations, limit the size of the image
file to 10 MBs for best performance; larger file sizes may significantly degrade system performance.
• When importing setup files (.rt files) from the line computer, you can not import more than one Tray per
Carrier (Level). In case you import more than one Tray per Carrier (Level), you have to create them
manually in SIPLACE Pro.
• In a multi-client scenario, when different users optimize the same job at the same time, the last Job to
finish will overwrite the other new Setups.
• The operator has to put Manual Tray Carriers (Carrier 30, Carrier 51, Carrier X) manually in the initial
setup.
• If you work with a reduced acceleration for a component shape you have a special case and the accuracy
of 5% of the simulated optimizer production time is not kept.
• The optimizer does not check if the tray size is bigger than the carrier.
• The WPC can take up to 10 different components types per level.

32- 72
Software Version Description Programming System SIPLACE Pro

5.2 Known Issues/Problems (General)

5.2.1 Installation
• When configuring a SIPLACE Pro machine, do not assign SIPLACEPro as computer name (case
insensitive).

Note:
If the machine name is already "SIPLACEPro" and during upgrade the system encounters the
problem with number of users connected (when no other users are connected), then rename
the machine or stop the SQL-Sever-Agent, perform the install, and, if necessary, restart the
SQL-Sever-Agent.

To stop the SQL-Server-Agent,

1. Open the SQL Enterprise Manager.


2. In the tree control, expand Microsoft SQL Servers Æ SQL Server Group Æ Server Name
(SIPLACEPRO) ÆManagement Æ SQL-Server-Agent.
3. Right click the Agent: a context menu appears.
4. Click Stop.
5. Close the Enterprise Manager.

• To re-start the SQL-Server-Agent after installation, repeat the steps above except for step 4: Choose
Start rather than Stop.

5.2.2 Placement Machine


• If the machine’s configuration (e.g., camera was not correctly configured) does not match the
configuration that has been sent to the machine via a download, SIPLACE Pro displays a “Data
Preparation Error” message.
o Mismatch of Head Type, Nozzle Changer Type, or Vision System has to be fixed in the
programming system.

Caution:
If the user does not correct the nozzle mismatch problem at the machine (as opposed to the
programming system), but instead switches the operating mode of the machine from SIPLACE
Pro to Stand Alone, then the machine will not accept any further downloads. In this case, the
machine has to be rebooted. This issue applies mainly to the HS-50, but may appear on other
Placement Systems as well.

5.2.3 Station-wise Download


• When the line control server is rebooted, station-wise downloading will be cancelled. After rebooting, you
will need to perform a complete line download to restart production.
• Station-wise downloading supports setup changes with simultaneous recipe definition at both conveyors,
when run in asynchronous dual operation.
• Station-wise download does not support synchronous dual conveyor operation.

33 - 72
Software Version Description Programming System SIPLACE Pro

5.2.4 Export restrictions from SIPLACE Pro to the Line Computer


It is possible to export Restrictions from SIPLACE Pro 2.0 onwards to the Line Computer, but because of
data structure differences Line Computer and SIPLACE Pro are different. The two main differences are:

1. The Line Computer forces you to select a specific Recipe and the created restriction is based on this
Recipe only. In SIPLACE Pro, you are free to use every Restriction with any Recipe in any Job.
The Line Computer cannot identify to which Recipe the Restriction belongs to and therefore the Line
Computer doesn't know where to save the restriction.

2. On the Line Computer, within each Restriction (i.e. for each Recipe), you bind specific Components
or Component Shapes with their Feeders to or exclude them from specific Tables or Machines. It
isn't possible to assign a Component or Component Shape without its Feeder because it’s part of the
data set.
In SIPLACE Pro, you restrict three specific objects (Feeders, Components and Component
Shapes) to or from Machines or Machine Sides. Here, the feeder is missing in the restriction.
The only Restrictions that can be exported from SIPLACE Pro are the Transport side (right or left) and the
Feeder as they are assigned to specific Components or Component Shapes. In SIPLACE Pro, this is the
work-around:

1. Create a Restriction for all relevant Components and Component Shapes you wish to restrict.

2. Open each of the Components and Component Shapes and determine which feeders are assigned
as default if not already available.

3. Back in the Restriction editor, add a new line for each of the default feeders. Please assign the
Feeder (target [station], right or left transport side [conveyer lane]).
Result: You should now have one line for each Component or Component Shape and another line
for each feeder, with all of those Objects assigned.
All entries are immediately saved in the database.

Note:
Make sure that you choose for all objects (Component, Component Shape, Feeder) the same
targets and sub targets.

Note:
You could only export the right or left machine side (conveyor lane) if you have selected „All“,
„Left“ or „Right“.

4. Start the Line Computer Export (Extras -> Export).


In the first screen, choose a destination path and the Restriction file you wish to export.

5. In the rest of the Line Computer Export, choose the Components and Component Shapes you want
added to the .ri file.

Note:
Be sure to check the box marked "Update feeder information." If you don't check the box
or select these Components and Component Shapes, then their information will not be added
to the .ri file make sure that you choose for all objects (Component, Component Shape,
Feeder) the same targets and sub targets.
6. When the export is complete, the result is shown in the notification window.

34- 72
Software Version Description Programming System SIPLACE Pro

5.2.5 Miscellaneous
• From SIPLACE Pro 2.0 onwards there is no body offset (x, y) in the component shape description. With
the body offset in former versions you could move the basic body of the component shape.
Following restrictions should be considered:
o Station software ≥ 504
All databases from SIPLACE Pro 1.4.x.x are adapted to SIPLACE Pro 3.0. The body offset
is automatically considered in the pickup point.
o Station software ≤ 504
Stations with this station software do not support any pickup point. Setups with component
shapes that are described in SIPLACE Pro 1.4.x.x with a body offset have to be adapted
manually to SIPLACE Pro 3.0.
• If a user modifies a Component Package's values after assigning it to a Component, then these values
will not be updated for the Component.
Workaround: Re-assign the Component Package to the Component after modifying Component
Package values.
• In previous SIPLACE Pro versions, the optimizer generated a placement sequence without regard for the
z-axis of tower feeders, e.g. WPC and MTC. Starting with SIPLACE Pro 3.2, all tower feeders are
automatically optimized so that the travel paths in the z-direction are reduced to a minimum. This is
intended to extend the lifetime of these z-axes.
• Please note that the feature “Support of SOKO/special design construction for Traceability 407” has only
been implemented in SIPLACE Pro 3.2 SP1, SIPLACE Pro 4.1SP1 and SIPLACE Pro 5.0.

35 - 72
Software Version Description Programming System SIPLACE Pro

5.3 Troubleshooting

5.3.1 Error Reporting Tool


The error report enables you to send details of errors occuring in SIPLACE Pro to Siemens AG. For more
details please refer to the Appendix D and the online help.

5.3.2 Creating a SPOT file


If the optimization result shows (in very few cases) an unsolvable error, you have the possibility to create a
SPOT file. Save this file, for example, on floppy disk and/or send the file with email to the software service
(SIPLACE.hotline@siemens.com).

With SIPLACE Pro 5.0 the SPOT files that are created by the optimizer are saved in the default folder “Spot”
or in a user specific folder. For more details please refer to the online help.

The new Error Reporting Tool collects all available SPOT files. In addition to the Error Reporting Tool the
user can also create individual SPOT files of certain actions. As default a SPOT file will be created.

• In SIPLACE Pro Desk, start the Job Editor.

• Click the Configure button:

36- 72
Software Version Description Programming System SIPLACE Pro

• Choose the tab Logging.


• In the Optimization Support field, check the Save optimization results in support format box:

Use the online and context-sensitive help functions to obtain a detailed explanation of the SPOT file.
Note:
Users logged on as operator (without Administrative Rights) cannot write into a folder below
"C:\Program Files" using Windows 2000/Windows Server 2003/Windows XP.
Workaround: The user can type in or copy and paste a valid path in front of the Spot file
name. The path and name will be saved to the database.

37 - 72
Software Version Description Programming System SIPLACE Pro

Online help (call by clicking the Help button in the dialog box described above):

Enter the context-sensitive help via:

• Online help from the menu bar


• Help button of the respective dialog
• F1 for context-sensitive help in some window display areas

5.3.3 Troubleshooting if a system feature is not usable after installation


Note:
Please note that is necessary to have administrative user rights to install SIPLACE Pro.

In rare cases it is possible that parts of the system are only installed when a specific feature (e.g. reporting)
is used for the first time after the installation. If the SetupCD is available in the drive from where the software
has been installed, this post-installation is automatically performed.
If the SetupCD is not in the drive (what is most likely the case), invocation of that feature will fail and produce
error messages like "could not load DLL" or even more cryptic like in the screen shot.

38- 72
Software Version Description Programming System SIPLACE Pro

If you experience such messages after installation, please check in the Event Log to see if the error message
is in fact caused by a failed post-installation. Please follow these steps to do this:
1. To open the Event Viewer, go to StartMenu->Run, enter "eventvwr" and click OK.
2. Select "Application Log". All logged application events will be displayed. The latest is at the top of
the list.
3. Check for entries of type "Error" from Source "MsiInstaller" at the correct time.
If you find such entries with a timestamp matching the time when you received the error, it is likely
that a post-installation has been invoked and failed due to the missing SetupCD.
If no such entries are found in the eventlog, the error message has another unknown reason.
If the above check had a positive result (point 3 above), the problem can be solved by
1. inserting the SetupCD in the drive from where you installed the software. If you installed from a
network drive, be sure that you use the same share with the same drive letter. If the installation
program starts automatically, please cancel.
2. retrying to invoke the feature which just failed. As soon as the post-installation has been performed
(with or without user feedback), the feature should start as expected. If it doesn't, the error message
has another unknown reason.

39 - 72
Software Version Description Programming System SIPLACE Pro

6 Notes
In this section, we provide information to enhance user productivity by ensuring

• SIPLACE Pro features are used correctly the first time and
• Users spend less time engaging in known courses of action that render inappropriate
results.

6.1 Preparation for Installation


• When upgrading from Windows NT 4.0 to Windows 2000 with an existing SIPLACE Pro database (e.g.,
one with production data), you have to use the “Manual Setup” for the installation of the operating
system (do not use the "Unattended Setup" because it deletes all content on the hard drive prior to
installation).

Note:
Any time a new database is created, it is necessary to import the master data:
In SIPLACE Pro desk go to Tools -->Import -->XML Import Wizard... or go to Tools-->Import
--> Component Shape Library...

Note:
SIPLACE Pro requires an NTFS partition to be installed on. FAT or FAT32 file systems are not
supported. The installation of SIPLACE Pro on FAT partitions is interrupted by the setup
program.

Note:
SIPLACE Pro object names (e.g., Recipe) must not exceed 125 ASCII characters (including
folder names). If the station being downloaded to has station software 504 or lower, then the
name will be truncated to 20 ASCII characters.

40- 72
Software Version Description Programming System SIPLACE Pro

6.2 Nozzles

6.2.1 9xx Nozzles on the Twin Head


9xx nozzles can only be used on the Twin Head with the aid of a nozzle adapter.
→ The nozzles must be defined as customized nozzles on the SIPLACE Pro Programming
system.
→ The following parameters must be adapted to allow the 9xx nozzles to be used optimally on
the Twin Head (Nozzle Properties – „Vacuum Settings“ field):
♦ Nozzle length (Nominal Length)
♦ Minimum difference
♦ Cubic Vacuum
♦ Non-cubic Vacuum
♦ Leaky Tolerance

→ The parameters for the corresponding 9xx nozzle are used as a template for the customer
nozzle.
Note:
It is important to ensure that the value for the parameter " non-cubic Vacuum " for the 9xx
nozzle is taken as the value for the " Cubic Vacuum " parameter of the new 5xx nozzle.

6.2.2 Meaning of the nozzle parameters and recommended values for the 9xx nozzles as
5xx nozzles on the Twin Head
• Nozzle Length (Nominal Length):
The nominal Z axis positions for pickup and placement are calculated using the specified nozzle
length.
A length value which is too high leads to a loss of placement performance while the automatic Z
height correction function of the machine compensates for the discrepancy.
Too low a value means that the Z axis makes contact at too high a speed with the component
during pickup and with the board during placement.
The nozzle length is calculated by adding the length of the nozzle adapter (without 9xx nozzle
seating) of 9.5 mm to the length of the 9xx nozzle. The total length to be entered corresponds to the
distance between the tip of the nozzle and the outer face of the adapter (without Twin Head
adapter).

Nozzle
adapter
length

41 - 72
Software Version Description Programming System SIPLACE Pro

• Minimum Vacuum (Min_Vak_Abstand):


This value corresponds to the minimum permitted difference in vacuum between the open nozzle
(without component) and the closed nozzle and is used to monitor wear and contamination (e.g. by
solder paste) of the nozzle. Monitoring is carried out during the overall reference run of the machine
and after a nozzle has been changed. If the minimum value is not achieved during the check, the
following error message is issued at the station: "The difference between open and closed vacuum
values is too small".
The parameter is entered as an absolute pressure value in units of 0.1 mbar.
The original value of the corresponding 9xx nozzle should be used when creating the 5xx customer
nozzle.
• Cubic Vacuum (Kub_Vak_Schwellwert):
This parameter is used on the Twin Head as the threshold for checking whether a component is on
the nozzle. If the detected value is below this threshold, a component is detected as being on the
nozzle.
The specified value is a percentage value (in units of 0.01 %) of the difference between the open
and closed vacuum value of the nozzle. The checking threshold is thus calculated as the open
vacuum value and the percentage difference value which is added to the open vacuum value.
For customer nozzles, the "Cubic Vacuum" parameter for the 9xx nozzle must be entered.
Values which are too high can lead to components not being detected on the nozzle and thus
possibly to incorrect placement (incorrect components being placed).
Values which are too low cause components to be incorrectly detected (vacuum value okay, but
no component on the nozzle).
• Non-cubic Vacuum (Nkub_Vak_Schwellwert):
This parameter is used on the Twin Head to determine the pickup threshold of a component. Once
the detected value has fallen below the pickup threshold, the pickup process is completed and the Z
axis can be positioned upward.
The pickup threshold is calculated in the same way as the "Cubic Vacuum" parameter.
For customer nozzles, it is recommended that a higher value is entered here than for the "Cubic
Vacuum" parameter. A guideline is to enter double the value of the "Cubic Vacuum" parameter.
If the value entered is too high, this may unnecessarily lengthen the pickup process, which
leads to a decrease in placement performance.
Values which are too low can negatively impact pickup reliability.
• Leaky Tolerance (Zul_Undichtigkeit):
This parameter is used on the Twin Head to define the air kiss pressure for placing components.
Once the detected value has exceeded the threshold value, the placement process is completed and
the Z axis can be positioned upward. The parameter value is calculated as a percentage value (in
units of 0.01 %) of the placement pressure entered for the component shape.
The value of the parameter depends on the degree of airtightness between the component and the
nozzle. The guideline value for the parameter is 5000 (i.e. 50%).
A value which is too low can cause components to be pulled up again and a value which is too
high can extend the placement process, thus causing a decrease in placement performance.

42- 72
Software Version Description Programming System SIPLACE Pro

6.3 Component Shape


• Object names in SIPLACE Pro (e.g. Recipe name) may not be longer than 50 ASCII characters (including
folder name). If the station software is 504 or older, these names are shortened to 20 ASCII characters.
• If Component Shapes are selected in the ASCII Centroid Import Wizard, all the existing links between
Components and Component Shapes will be overwritten with the imported information.
• New Component Shape GF 1051 for new Component 1206 Capacity heavy 3.2 x 1.6 x 1.8
The new component shape GF 1051 of the standard component shape library places thicker capacitors
without any problems. In contrast to GF 1050 the new GF 1051 uses only the bigger nozzles.
Component Shape (CS): 1051
Component: 1206 Capacity heavy 3.2 x 1.6 x 1.8 (mm)
Nozzles: 713, 733, 913, 933, 1033, 1133

6.4 Printing Reports


The generated reports can be sorted by various criteria (such as placement list etc.).
Within the printing preview the sort criteria can be modified as well.
Note:
If you have printing problems when printing reports please check your specific printer
properties (e.g. borderless printout).

6.5 Backup of System Feeder Inventory


When upgrading SIPLACE Pro (starting with SIPLACE Pro 3.0) an updated system feeder inventory is
imported (SystemFeederInventory.xml) in order to consider all new feeder types. The feeder inventory that is
already existing in SIPLACE is renamed (Backup of System Feeder Inventory_X). All existing jobs are not
changed. All new jobs contain the updated (newly imported) feeder inventory.

43 - 72
Software Version Description Programming System SIPLACE Pro

7 Corrected Defects (from SISCOPE)


Following defects are solved in SIPLACE Pro 5.0

Defect ID Corrected Defect - Description

1-DNM8D Siplace Pro board editor shifts subclusters in wrong direction.

1-FWRG1 Siplace Pro does not show the corresponding values from the view in the grid list.

1-G2F2X During download to the line the placement machine HF/3 does not accept the recipe.

1-GEBB9 Fatal error during download with feeders that are not needed.

1-HLSLY CAD Import stops with error.

1-I17ZP Converting placement position to inkspot doesn't work properly..

1-IJN4E BGA cannot be exported from SiplacePro to Linux.

1-INZMO LRL- Import failed with error "Object reference not set to instance of an object".

1-IXW0Z No comment in pcb after conversion from line computer to SiplacePro (4.0).

1-J3DOP Download of a X4 with i.e. 2 boards results in errors during data processing.

1-J3LBN Teach data from some component shapes are not transferred to SIPLACE Pro.

1-J66G9 Large cycletime difference for an optimization, with and without coplan module.

1-J66IV Waiting time in the component shape do not influence the cycle time.

1-J6FN4 Certain components setup twice.

Installation fails to install on Window 2003 Server with CurrentCulture "Czech (Czech
1-J6ZPR Republic)"

1-JA729 Line is in alphabetical station name order.

6QD-1ES Function 'Delete Job Tree' does not work as expected and documented.

D1-32347301 By using the clipboard for tables the feeder division get wrong.

D1-32478203 Job can be optimized but not downloaded, D1 Single Head.

D1-32494601 Can´t import a XML-file.

D1-32520008 Can not change the name of the placement position.

D1-32783313 Optimizer ends with error message but error message does not show any details.

D1-32787801 When importing the same XML file twice an error message is displayed.

44- 72
Software Version Description Programming System SIPLACE Pro

Defect ID Corrected Defect - Description

D1-33042001 SIPLACE Pro aborts after download with LES.

D1-33081401 Too many "green" jobs in the LC GUI.

Error message on station after sending a job with placement program for long board
D1-33395002 option.

ASCII Centroid Import Wizard: objects are overwritten although the function overwrite
D1-33506801 is deactivated.

SIPLACE Pro Start failed, because License manager lost license key and does not
D1-33607701 accept any other key.

After CAD import, closing and re-opening the Desk, components are missing from
D1-33652412 placement lists.

D10421-11 Incorrect Optimization Result Displayed.

D9987-1625 Monitor flickers at all clients if too many components are deleted.

45 - 72
Software Version Description Programming System SIPLACE Pro

Appendix A: Supported Hardware

Norms and Standards


SIPLACE recommends to comply with following norms and standards for all line computers (SIPLACE Pro
Server, SIPLACE Pro Client, SIPLACE Stand Alone Configuration).

Compliance with Norms and Standards


Product safety
Global IEC 60950
Europe EN 60950
USA UL 60950 3rd. Ed.
Canada CAN/CSA-C22.2 No. 60950 3rd Ed.
Electromagnetic compatibility
Europe EN 55 022 Class B, EN 55024,
EN61000-3-2 /-3
USA / Canada FCC Class A
Declaration of conformity
Europe (CE) 89/336/EWG (EMW)
72/213 EEC (LVD)
North America FCC Class A
Useability
Europe EN ISO 9241-11

46- 72
Software Version Description Programming System SIPLACE Pro

Supported Stations
SIPLACE Pro 5.0 supports the following Placement Systems:

• SIPLACE 80 F4 (v. 407.xx)


• SIPLACE 80 F4-6 (v. 407.xx)
• SIPLACE F5 (v. 407.xx)
• SIPLACE F5 HM (v. 407.xx, 408.xx)
• SIPLACE 80 S-20 (v. 407.xx)
• SIPLACE S-23 (v. 407.xx, 408.xx)
• SIPLACE S-25 HM, SIPLACE S-27 HM (v. 502.xx/503.xx/505.xx)
• SIPLACE HS-50 (v. 502.xx/503.xx/505.xx)
• SIPLACE HS-50+ (v. 503.xx/505.xx)
• SIPLACE HS-60 (v. 503.xx/505.xx)
• SIPLACE HF (v. 504.xx/505.xx)
• SIPLACE HF/3 (v. 505.xx)
• SIPLACE X2, X3, X4 (v. 601.xx/602.xx)
• SIPLACE CF, CS (101, 408)
• SIPLACE D3, D4 (602.xx)
• SIPLACE X2, X3, X4, D1, D2, D3, D4 (603.xx, 604.xx)

Supported Nozzles
Currently the following nozzles are supported:

• 412 PP, 416 PP, 417 PP, 418 PP, 419 PP


• 451 PP, 452 PP, 453 PP, 454 PP, 455 PP, 456 PP
• 490 PP, 491 PP, 492 PP, 493 PP, 494 PP, 495 PP, 496 PP, 497 PP, 498 PP, 499 PP
• 516 PP, 517 PP, 518 PP, 519 PP
• 551 PP LF, 552 PP LF, 553 PP LF, 554 PP LF, 555 PP LF, 556 PP LF
• 590 PP, 591 PP, 592 PP, 593 PP, 594 PP, 595 PP, 596 PP, 597 PP, 598 PP, 599 PP
• 700 RV, 701 RV, 702 RV, 704 RV, 705 RV, 706 RV
• 711 RV, 713 RV, 714 RV, 715 RV, 717 RV, 718 RV, 719 RV
• 720 RV, 721 RV, 723 RV, 724 RV, 725 RV, 726 RV
• 730 RV, 731 RV, 732 RV, 733 RV, 734 RV, 735 RV, 736 RV, 737 RV, 738 RV, 739 RV
• 751 RV, 752 RV, 753 RV, 754 RV, 755 RV, 756 RV
• 790 RV, 791 RV, 792 RV, 793 RV, 794 RV, 795 RV, 796 RV
• 817 RV6, 820 RV6, 821 RV6
• 890 RV6, 891 RV6, 892 RV6, 893 RV6, 894 RV6, 895 RV6, 896 RV6, 897 RV6, 898 RV6, 899 RV6
• 900 RV, 901 RV, 902 RV, 904 RV, 905 RV, 906 RV, 907 (CRND), 911 RV, 913 RV, 914 RV, 915 RV, 917
RV, 918 RV, 919 RV
• 920 RV, 921 RV, 923 RV, 924 RV, 925 RV, 926 RV

47 - 72
Software Version Description Programming System SIPLACE Pro

• 930 RV, 931 RV, 932 RV, 933 RV, 934 RV, 935 RV, 936 RV, 937 RV, 938 RV, 939 RV
• 951 RV, 952 RV, 953 RV, 954 RV, 955 RV, 956 RV
• 990 RV, 991 RV, 992 RV, 993 RV, 994 RV, 995 RV, 996 RV
• 1001 C&P20, 1003 C&P20, 1004 C&P20, 1005 C&P20, 1006 C&P20, 1007 (CRND), 1011 C&P20, 1014
C&P20, 1032 C&P20, 1033 C&P20, 1034 C&P20, 1035 C&P20, 1036 C&P20, 1133 C&P20, 1135
C&P20, 1235 C&P20

Supported Nozzle Changers

SIPLACE Pro 5.0 supports the following nozzle changers:

• NC PP 1 (IC nozzle changer F4/6; F5; F5HM and CF)


• NC RV 6 8xx9xx (F5HM with 6-nozzle head; S25 HM with 6-nozzle head), NC RV 6 12 8xx (S25 HM with
6-nozzle head), NC RV 6 12 9xx (S25 HM with 12-nozzle head)
• NC RV 12 9xx (S25HM with 12-nozzle head ;F5HM with 12-nozzle head), NC RV 12 9xx HS, NC RV 12
9xx HS_2
• NC TWIN 3 1, NC TWIN 5 2, NC TWIN 8 4, NC TWIN Flexible 10 (for location 2/4), TWIN Flexible (for
location 1/3)
• NC RV 12 7xx (S20 and F4 12-nozzle C&P head)
• NC RV 6_ 7xx8xx (F4/6 and F5 6 C&P head)
• NC C&P20 10xx
• NC RVC 6 9xx (CF & CS)

Supported Feeder Modules

SIPLACE Pro 5.0 supports the following Surftape feeder modules:

• 8mm ST, 12mm ST, 16mm ST, 24mm ST

Note:
Station Software 504 supports surftape feeder for the revolver heads but not for the TwinHead.
In case of fixed setups the user must know that he/she has to set up the surftape feeder on
the revolver head side.
In case of optimized setups the user should / must ensure that the surftape feeder won't be
used by the Twin Head by configuring the nozzles accordingly.
Therefore, the user must not assign Twin Head nozzles to component shapes already
assigned to a surftape feeder.
With Station Software 505 the surftape feeder will be available even for the TwinHead.

48- 72
Software Version Description Programming System SIPLACE Pro

Allocation of Feeder Types to Station Types (1/2)


Feeder type

Track Type

S-20, S-23
Order No.
LC name

S-25HM
S-27HM

80 F4-6
HS-50
HS-60

80 F4
HF/3
CS

CF

HF
D4

D3

D2

D1
X4

X3

X2


8 mm X 141270 x x x
12 mm X 141271 x x x
16 mm X 141272 x x x
24 mm X 141273 x x x
32 mm X 141274 x x x
44 mm X 141275 x x x
52 mm X 141276 x x x
72 mm X 141277 x x x
88 mm X 141278 x x x
Carrier XTH x x x
Carrier X x x x
Arbitrary Carrier x x x
X
*
8mm EL 8 S_G_8_EL 141080 X X x x x x
8mm S 150 S_G_8_S 141096 X X o o o x x x x x x x x x
8mm ST ** 80 ST_8 - X X o o o x x x x x x x x x
3 x 8mm S 79 S_G_3x8_S 141098 X X o o o x x x x x x x x x
3 x 8mm S0201 78 S_G_3x8_S_020 141099 X X o o o x x x x x x x x
1
3 x 8mm S01005 x x X x x x x
3 x 8mm SL x x x x x x x x x x x
12mm * 11 S_G_12 141112 X X x x x x
12mm S 60 S_G_12_S 141092 X X o o o x x x x x x x x x
12mm ST ** 81 ST_12 - X X o o o x x x x x x x x x
16mm * 12 S_G_16 141112 X X x x x x
16mm S 61 S_G_16_S 141092 X X o o o x x x x x x x x x
16mm ST ** 82 ST_16 - X X o o o x x x x x x x x x
24mm III * 56 S_G_24_III 141121 X X x x x x
24mm S 62 S_G_24_S 141093 X X o o o x x x x x x x x x
24mm ST ** 83 ST_24 - X X o o o x X x x x x x x x
32mm III * 57 S_G_32_III 141121 X X x x x x x x
32mm Paper 15 S_G_32P 176006 X X x x x x x x x
32mm S 63 S_G_32_S 141093 X o o o x x x x x x x x x
44mm III * 58 S_G_44_III 141152 X x x x x x
44mm S 64 S_G_44_S 141094 X o o o x x x x x x x

56mm III * 59 S_G_56_III 141172 X x x


56mm S 65 S_G_56_S 141095 X o o o x x x x x x
72mm S 66 S_G_72_S 141097 X o o o x x x x x x
88mm S 67 S_G_88_S 141070 X o o o x x x x x x

49 - 72
Software Version Description Programming System SIPLACE Pro

Feeder type

Track Type

S-20, S-23
Order No.
LC name

S-25HM
S-27HM

80 F4-6

F 5 HM
HS-50
HS-60

80 F4
HF/3
CS

CF

HF
D4

D3

D2

D1
X4

X3

X2

F5


Arbitrary Carrier - - 176011 x x o o o x x x x x x x x
176012
BC 0402 0603 * 6 S_R_0402_0603 143009 x x x x x x x
BC AIR 153 S_B_AIR 142318 x o o o x x x x X x x x x x
Carrier 30 - S_M_FB_30 116433 x x o o o x x x x X x x x x x
Carrier 51 - S_M_FB_51 116431 x x o o o x x x x X x x x x x
Linear 10 3 S_LIN_10 142031 x x o o O x x x x X x x x x x
Linear 15 4 S_LIN_15
Linear 30 5 S_LIN_30
Linear 95 2 S_LIN_95
Linear 3x95 AX 514 x x x
Linear 2x15 AX 516
Linear 30 AX 517
MTC 1 - MTC_2x40_Level 116436 x
s
MTC 2 - - 116438 x x x x x
Reject Conveyor 50 S_SIP 141200 x x O o o x x x x x x x x
SIPLACE
Reject Conveyor x x x x x x x x X
Express
DIP-Modul 20 x O o o x x x x x X x
DIP-Modul (LDU) x x x
X-Tisch
WPC 3 *** - WPW3_28_Level 116427 x x x x
s 116441
116428
116442
116429
116443
116434
116444

WPC* - WPW_28_Levels 307143 x x x


306039
WPC 4 x
Tray Loader x x
****
TrayStak***** 250 - - o o x x x x X x
DDF2** 250 Hover Davis - o o x x x x x
DataIO 250 DataIO - o o o x x x x
RoadRunner
Label Presenter ??? X x X x x x
Label Presenter 552 x x X
AX

X feeder type is supported


o feeder type is supported only with changeover table SIPLACE HF (changeover table 90)
o feeder type is supported only with changeover table SIPLACE HF (changeover table 90);
changeover table HF could not be used together with C&P 20 Head.
50- 72
Software Version Description Programming System SIPLACE Pro

*
Phased out product
**
Product of Hover Davis, require sspecial Hover Davis table
***
These WPC are different in their height and their WTC (Waffle Tray Carrier).
**** Product of ASYS
***** Product of Besi

Note:
The DIP module does not work together with the C&P 20 Head.

51 - 72
Software Version Description Programming System SIPLACE Pro

Allocation of Feeder Types to Station Software Version (1/4)


Station Software 604 – 504
Station Software
Version Æ SIPLACE Pro 5.0 604 / 603 602 601 505

HS50+ (Option)
SIPLACE X4

SIPLACE X3

SIPLACE X2

SIPLACE X4

SIPLACE X3

SIPLACE X2

SIPLACE X4

SIPLACE X3

SIPLACE X2

S25HM

S27HM
HS50

HS60
Additional

HF/3
Feeder type

HF
D4

D3

D2

D1

D4

D3
information
LINEAR 10 S-Table x x x x x x x x x x x x x x x x x x x x x x x
LINEAR 15 S-Table x x x x x x x x x x x x x x x x x x x x x x x
LINEAR 30 S-Table x x x x x x x x x x x x x x x x x x x x x x x
LINEAR 95 S-Table x x x x x x x x x x x x x x x x x x x x x x x
Linear 3x95 AX X-Table x x x x
Linear 2x15 AX X-Table x x x x
Linear 30 AX X-Table x x x x
Label Presenter S-Table x x x x x x x x x
Label Presenter AX X-Table x x x x
12mm S S-Table x x x x x x x x x x x x x x x x x x x x x x x
16mm S S-Table x x x x x x x x x x x x x x x x x x x x x x x
24mmS S-Table x x x x x x x x x x x x x x x x x x x x x x x
24mm III S-Table x x x
32mm S S-Table x x x x x x x x x x x x x x x x x x x x x x x
32mm Paper S-Table x x x x x x x x x x x x
32mm III S-Table x x x
3 x 8mm S S-Table x x x x x x x x x x x x x x x x x x x x x x x
3 x 8mm S 0201 S-Table x x x x x x x x x x x x x x x x x x x x x x
3 x 8mm S 0201 S-Table x x x x x x x x x x x x x x x x x x x x x x
3 x 8mm S 01005 S-Table x x x x x x x
44mm S S-Table x x x x x x x x x x x x x x x x x x x x
44mm III S-Table x x x
56mm S S-Table x x x x x x x x x x x x x x x x x x x x
56mm III S-Table x x x
72mm S S-Table x x x x x x x x x x x x x x x x x x x x
88mm S S-Table x x x x x x x x x x x x x x x x x x
8mm S S-Table x x x x x x x x x x x x x x x x x x x x x x x
8mm EL S-Table x x x
BC AIR S-Table x x x x x x x x x x x x x x x x x x x x x x x
R 0402 0603 (BC 0402S-Table x x x x x
12mm ST (Surf Tape FS-Table x x x x x x x x x x x x x x x x x x x x x x x
16mm ST (Surf Tape FS-Table x x x x x x x x x x x x x x x x x x x x x x x
24mm ST (Surf Tape FS-Table x x x x x x x x x x x x x x x x x x x x x x x
8mm ST (Surf Tape FeS-Table x x x x x x x x x x x x x x x x x x x x x x x
12mm S-Table x x x
16mm S-Table x x x

52- 72
Software Version Description Programming System SIPLACE Pro

Allocation of Feeder Types to Station Software Version (2/4)


Station Software 503 – 101
Station Software
Version Æ 503 502 408 407 101

HS50+ (Option)
Additional
Feeder type
information

S25HM

S27HM

S25HM

F5HM

F5HM
HS50

HS60

HS50

F4-6
S23

S20

S23
CS

CS
CF

CF
F4

F5
LINEAR 10 S-Table x x x x x x x x x x x x x x x
LINEAR 15 S-Table x x x x x x x x x x x x x x x
LINEAR 30 S-Table x x x x x x x x x x x x x x x
LINEAR 95 S-Table x x x x x x x x x x x x x x x
12mm S S-Table x x x x x x x x x x x x x x x x x x x
16mm S S-Table x x x x x x x x x x x x x x x x x x x
24mmS S-Table x x x x x x x x x x x x x x x x x x x
24mm III S-Table x x x x x x x x x x x x x x x
32mm S S-Table x x x x x x x x x x x x x x x x x x x
32mm Paper S-Table x x x x x x x x x x x x x x x x x x x
32mm III S-Table x x x x x x x x x x x x x x x
3 x 8mm S S-Table x x x x x x x x x x x x x x x x x x x
3 x 8mm S 0201 S-Table x x x x x x x x x x x x x x
44mm S S-Table x x x x x x x x x x
44mm III S-Table x x x x x x x x x x
56mm S S-Table x x x x x x x x x x
56mm III S-Table x x x x x x x x x x
72mm S S-Table x x x x x x x x x x
88mm S S-Table x x x x x x x
8mm S S-Table x x x x x x x x x x x x x x x x x x x
8mm EL S-Table x x x x x x x x x x x x x x x x
BC AIR S-Table x x x x x x x x x x x x x x x x x x x
R 0402 0603
(BC 0402 0603) S-Table x x x x x x x x x x x x x x x x
12mm ST (Surf Tape) S-Table x x x x x x x x x x x x x x x x
16mm ST (Surf Tape) S-Table x x x x x x x x x x x x x x x x
24mm ST (Surf Tape) S-Table x x x x x x x x x x x x x x x x
8mm ST (Surf Tape) S-Table x x x x x x x x x x x x x x x
12mm S-Table x x x x x x x x x x x x x x x
16mm S-Table x x x x x x x x x x x x x x x

53 - 72
Software Version Description Programming System SIPLACE Pro

Allocation of Feeder Types to Station Software Version (3/4)


Station Software 604 – 504
Station Software
Version Æ 604 / 603 602 601 505 504

HS50+ (Option)
SIPLACE X4

SIPLACE X3

SIPLACE X2

SIPLACE X4

SIPLACE X3

SIPLACE X2

SIPLACE X4

SIPLACE X3

SIPLACE X2

S25HM

S27HM
HS50

HS60
Additinal

HF/3
HF

HF
Feeder type
D4

D3

D2

D1

D4

D3
Information

New Feeder Generation x x x


(8mm – 88mm) X-Table x x x x x x
(x-feeder) Feeder intelligence x x x x x x x x x
“hot swap”
–capability per
feeder location
“Mixed” operation
in combination with
Current Feeder x x x
Generation x x x x x x
8mm X X-Table x x x x x x x x x
12mm X X-Table x x x x x x x x x
16mm X X-Table x x x x x x x x x
24mm X X-Table x x x x x x x x x
32mm X X-Table x x x x x x x x x

44mm X X-Table x x x x x x x x x

56mm X X-Table x x x x x x x x x

72mm X X-Table x x x x x x x x x

88mm X X-Table x x x x x x x x x
Reject Conveyor
(SIPLACE) S-Table x x x x x x x x x x x x x x x x x x x x x
(Option) X-Table
Reject Conveyor
(Component Express) S-Table x x x x x x x x x x x x x x x x x x
(Option) X-Table x x
S-Table x x x x x x x x x x x x x x x x x x
Dip Modul X-Table x x
DDF 2 Hover Davis x x x x x x x x + + + + + x x x x x x
Data IO Runner S-Table x x x x x x x
Tray Stack x x x x o o o o o o x x x x x x x
Tray Loader x x

54- 72
Software Version Description Programming System SIPLACE Pro

Allocation of Feeder Types to Station Software Version (4/4)


Station Software 503 – 101
Station Software
Version Æ 503 502 408 407 101

SIPLACE Pro 5.0

HS50+ (Option)
Additional
Feeder type
information

S25HM

S27HM

S25HM

F5HM

F5HM
HS50

HS60

HS50

F4-6
S23

S20

S23
CS
CF

CF
F4

F5
8 mm S X-Table x
12 mm S X-Table x
16 mm S X-Table x
24 mm S X-Table x
32 mm S X-Table x
44 mm S X-Table x
56 mm S X-Table x
72 mm S X-Table x
88 mm S X-Table x

S-Table x x x x x x x x x x x x x x
Reject Conveyor
(SIPLACE Option) X-Table
Reject Conveyor
S-Table
(Component Express)
(Option) X-Table
S-Table
Dip Modul X-Table
DDF 2 Hover Davis x
Tray Stack x
Tray Loader X-Table x

55 - 72
Software Version Description Programming System SIPLACE Pro

Supported Table Types

SIPLACE Pro 5.0 supports the following Table Types:

• Change Over Table 72 (Change Over Table SIPLACE HS)


• Change Over Table 90 (Change Over Table SIPLACE HF / SIPLACE X series)
• Change Over Table 120, Change Over Table 120 MTC 1 (Change Over Table SIPLACE SF)
• Table WPC 120
• Table MTC 2 (virtual – no setup space for feeders)
• Change Over X-Table 40 (Change Over Table SIPLACE X)
• WPC 90 D (für WPC 4)
• Table 90 D

Station Software 603 – 504

Stations Software
Version -> 604 / 603 602 601 505 504
SIPLACE Pro 5.0

HS50+ (Option)
SIPLACE X4

SIPLACE X3

SIPLACE X2

SIPLACE X4

SIPLACE X3

SIPLACE X2

SIPLACE X4

SIPLACE X3

SIPLACE X2
Additional
Feeder type
information

S25HM

S27HM
HS50

HS60
HF/3
HF

HF
D4

D3

D2

D1

D4

D3

S-Table 60 Tracks & WPW x


54 Tracks & MTC 1 x x x
MTC 2 Table x x x x x x x x x x x x
120 Tracks x x x
72 Tracks x x x x x x
90 Tracks x x x x x x x x x x x x x x x
90 Tracks D-Serie x x x
Tables S-Tables: 5 mm
30 Tracks & WPC x x
tracks X-Tables: 12
mm tracks X-Table 40 Tracks* x x x x x x x x x x
table fiducials x x x x x x x x x x

56- 72
Software Version Description Programming System SIPLACE Pro

Station Software 503 – 101

Stations Software
Version -> 503 502 408 407 101

SIPLACE Pro 5.0

HS50+ (Option)
Additional
Feeder type
information

S25HM

S27HM

S25HM

F5HM

F5HM
HS50

HS60

HS50

F4-6
S23

S20

S23
CS

CS
CF

F4

F5
S-Table 60 Tracks & WPW x
54 Tracks & MTC 1 x x x
MTC 2 Table x
120 Tracks x x x x x x x x x x
72 Tracks x x x x x
Tables S-Tables: 5
90 Tracks x
mm tracks X-Tables:
12 mm tracks X-Table 40 Tracks* x
WPC x x x x x x x

Note:
The S Change Over Table Family includes following table types: HF, S, F und HS.

57 - 72
Software Version Description Programming System SIPLACE Pro

Supported Vision Systems

SIPLACE Pro 5.0 supports the following Vision System Types for placement machines:

• ICOS Vision System: MVS 200, MVS 340


• SIPLACE Vision V30, V32, V33, V34

Supported Sensor Modules (1/2)


Station Software 604 – 504
Station Software

SIPLACE Pro 5.0


Version ->>> 604 / 603 602 601 505 (x: basic; x+: full) 504
max.

SIPLACE X4

SIPLACE X3

SIPLACE X2

SIPLACE X4

SIPLACE X3

SIPLACE X2

SIPLACE X4

SIPLACE X3

SIPLACE X2

(Option)

S25HM

S27HM
HS50+
HS50

HS60
Component Size

HF/3
HF

HF
D4

D3

D2

D1

D4

D3
Features (single frame)
MVS 200 x x x
MVS 340 x x x x x x x x x
Vision System SIPLACE Vision x x x x x x x x x x x x x x x x
Sensor 5 x x x x x x x x x
Sensor 18 (Mulicolor) x x x x x x x x x
PCB Camera Sensor 24 x x x x x x x x x x x x
Sensor 34 x x x x x x x x x x x x x x x x
Comp. Cameras Sensor 12 C&P 12 18,7mm x x x x x x x x x
for C&P 6, C&P 12, Sensor 13 C&P 6 32mm x x x x x x
C&P 20 Head Sensor 14 (DCA) C&P 6 13mm x x x x x x
Sensor 23 C&P 20 6mm x x x x x x x x x x
Sensor 28 C&P 6 / 12 18,7mm x x x x x x x x x x x x x x x x
Sensor 29 C&P 6 / 12 27mm x x x x x x x x x x x x x x x x
Sensor 38 C&P 12 x x x x x x
Comp. Cameras Sensor 7 P&P 32mm x x x X
(stationary) Sensor 10 P&P 32mm x x x X
for Pick&Place (P&P) Sensor 11 (DCA) P&P 15mm x

and Twin Head (TH) Sensor 20 TH 8mm x x x x


Sensor 22 TH 50x40mm x x x x
Sensor 25 (DCA) TH 16mm x x x x x x x x x x
Sensor 33 TH 55x45mm x x x x x x x x x x
Sensor 8 P&P 43mm x
Sensor 17 P&P, TH x x x x
Coplanarity Module
Sensor 31 TH x x x x x x x x x x
3D Coplanarity TH x x x x x x x
C&P 12 x x x x x x x x x x x x x

58- 72
Software Version Description Programming System SIPLACE Pro

Supported Sensor Modules (2/2)


Station Software 503 - 101

Softwareversion der
Stationen>>> 503 502 408 407 101

(Option)
max.

S25HM

S27HM

S25HM
HS50+

F5HM

F5HM
HS50

HS60

HS50
Component Size

F4-6
S23

S20

S23
CS

CS
CF

CF
F4

F5
Features (single frame)

MVS 200 x x x x x x
MVS 340 x x x x x x x x x x x x x x x x
Vision System SIPLACE Vision
Sensor 5 x x x x x x x x x x x x x x x x x x x
Sensor 18 (Multicolor) x x x x x x x x x x x
PCB-Camera Sensor 24
Sensor 34
Comp. Cameras Sensor 12 18,7mm x x x x x x x x x x x x x x x x x
for C&P 6, C&P 12, Sensor 13 32mm x x x x x x x
C&P 20 Head Sensor 14 (DCA) 13mm x x x x x x x x
Sensor 23 6mm

Sensor 28 18,7mm

Sensor 29 27mm

Comp. Cameras Sensor 7 32mm x x x x x x x


(stationary) Sensor 10 32mm x x x x x x x
for Pick&Place (P&P) Sensor 11 (DCA) 15mm x x x x x
and Twin Head (TH) Sensor 20 8mm

Sensor 22 50x40mm

Sensor 25 (DCA) 16mm

Sensor 33 55x45mm
Sensor 8 43mm x x x x x x x
Coplanarty Module Sensor 17 x x x x x x x
C&P 12 x x x x x x x
Comp.- Sensor C&P 20

59 - 72
Software Version Description Programming System SIPLACE Pro

Appendix B: Shared Interfaces

Line Computer UNIX


The import / export functions of SIPLACE Pro 4.0 support the following versions of the Line Computer UNIX:

• LRU.501.xx
• LRU.502.xx
• LRU.503.xx

The following files can be exported to the Line Computer:

• .be files (Components)


• .sgf files (Component Shapes)
• .ri file (Restrictions: Component/ Component Shapes– Feeder Type)
• .qd files (Board)
• .pm files (Fiducials)
• .rt files (Setup)

The following files can be imported from the Line Computer:

• .be files (Components)


• .sgf files (Component Shapes)
• .ri file (Restrictions: Component/ Component Shapes– Feeder Type)
• .qd files (Board)
• .pm files (Fiducials)
• .rt files (Setup)

60- 72
Software Version Description Programming System SIPLACE Pro

Appendix C: Platform – Station Software – Machine


The following table gives an overview of the SIPLACE platform together with the station software and the
machine types.

Platform Station Software Machine type

Platform II + 604 D-Serie: D1, D2, D3, D4


X-Serie: X2, X3, X4
603 D-Serie: D1, D2, D3, D4
X-Serie: X2, X3, X4
602 D-Serie: D3, D4
X-Serie: X4, X3, X2
601 X-Series: X4, X3, X2
Platform II 505 HF
HF/3
HS50
HS50+ (optional)
HS60
S25HM
S27HM
504 HF
503 HS50
HS50+ (optional)
HS60
S25HM
S27HM
502 HS50
S25HM
Platform I 408 S23
F5HM
CS
CF
407 S20
S23
F4
F4-6
F5
F5HM

61 - 72
Software Version Description Programming System SIPLACE Pro

Platform Station Software Machine type

C Series 408 CF
CS
101 CF
CS

62- 72
Software Version Description Programming System SIPLACE Pro

Appendix D: Data Collection Policy


SIPLACE Pro Error Reporting asks users to send error report data to Siemens.The following explains the
nature of the data, why it is collected, and what is done with it.

Why error data is collected


Error report data is used to find and fix problems in the software you use. It is not used for marketing
purposes.

What data is collected


To fix problems in the software you use, we need information about what the software was doing when it
experienced the problem, and about your machine configuration. For a description of the categories of data
we collect, see the section below called Types of Data.
When collecting information, it is possible for personal or confidential information to be present in the report.
For instance, a snapshot of memory may include your name, part of a document you were working on, or
data you recently submitted to a Web site. It is also possible for personal information to be included in a log
file, a portion of the registry, or other product specific files needed to determine the cause of the problem. If
you are concerned that the report may contain personal or confidential information, please do not send the
report.
You may be asked to answer a survey after sending an error report. Responding to the survey is optional. If
you send an error report without sending survey information, your error report remains anonymous. If you
choose to provide a phone number or email address then we may contact you to ask for additional data that
will help us solve a problem.

How data is stored


When you submit an error report, we protect it through the use of encryption, such as the Secure Socket
Layer (SSL) protocol. When we receive an error report, we use a variety of security technologies and
procedures to help protect your personal information from unauthorized access, use, or disclosure. For
example, we store the error reports you provide on computer servers with limited access.

Who has access to error report data


Siemens employees, contractors and vendors who have a business need to use the error report data are
provided access. If the error report indicates that a third-party product is involved, Siemens may send the
data to the vendor of that product, who may in turn send the data to sub-vendors and partners.

Types of Data
The Error Reporting service is integrated into Siemens products and is used to report a wide variety of
errors. This section presents many of the potential pieces of data that may be collected as part of the error
report, but is not an exhaustive list. The type of data and amount of data we request is dependent on the
severity of the error and relevance of the data to troubleshooting the problem.

63 - 72
Software Version Description Programming System SIPLACE Pro

Recent Actions
Data about recent actions taken by you or the software application, such as:
• The task you were working on at the time
• Menus or toolbars you clicked on
• Dialogs that were displayed at the time of the error

Network
Data related to your network connections, such as:
• IP address (identifies your computer on the internet)
• Names of Web sites you recently visited
• Information you submitted to Web sites

Machine Configuration
Data about your physical machine, such as:
• Devices and components installed on your machine
• Plug and Play ID (PnP ID) and description of devices
• Machine name
• System name, type, model and manufacturer
• Amount of RAM, hard disk size, number of processors
• BIOS version and data
• Registry data

Files
Names, versions and copies of actual files, such as:
• Your documents
• Application files
• Configuration files
• Setup logs
• Networking report summary
• Diagnostic logs
• Eventlog files

Memory
Data contained in specific segments of memory, such as:
• Application instructions being executed at the time of a crash
• Data values stored temporarily by the application
• Program files and drivers that have been loaded into memory
• Full memory dump (dependent on type of error encountered)

Software Configuration
64- 72
Software Version Description Programming System SIPLACE Pro

Data about the configuration and settings of software on your machine, such as:
• Your software license
• Operating system name, version and language
• Filenames and versions installed in the affected application's directory
• Installed drivers, fonts, templates, add-ins, themes, ActiveX controls
• Registry settings

65 - 72
Software Version Description Programming System SIPLACE Pro

Appendix E: Acceleration Data

66- 72
Software Version Description Programming System SIPLACE Pro

67 - 72
Software Version Description Programming System SIPLACE Pro

68- 72
Software Version Description Programming System SIPLACE Pro

69 - 72
Software Version Description Programming System SIPLACE Pro

Appendix F: Overview Vision Systems


For SIPLACE placement sytems different vision systems are available:
System Type
ICOS vision system MVS 200
MVS 340
SIPLACE vision system 30x
32x
33x
34x

The new SIPLACE vision system has different functions depending on the version. Following table lists the
different versions dependent on the functions and the station software:

Station Software Version SIPLACE Vision System SIPLACE Vision Functions


SW 601.0x 30x
SW 602.0x 32x
SW 603.0x 33x ƒ Check of smaller CS
structures deactivated
ƒ Incomplete CS description
ƒ Centering pins
ƒ Component orientation check
SW 604 34x ƒ Coplanarity tolerances in
component shape editor

70- 72
Software Version Description Programming System SIPLACE Pro

71 - 72
Siemens AG 2006 All rights reserved Subject to change without prior notice

Order No.: 00195480-01 Siemens AG

Siemens AG, Automation and Drives


Electronics Assembly Systems
Rupert-Mayer-Strasse 4
D-81359 Munich / Germany

Printed in the Federal Republic of Germany