Byte Bit Name Beschreiung Server Clt Slv Master DP

0 0 Value Bit 0 Wert für Single Point oder R W R W W


Double Point
1 Value Bit 1 Wert für Double Point R W R W
2 HW Value Bit 0 Hardware Status W W W
3 HW Value Bit1 W W
4 subEna Trigger Substitue Enabled Trigger R
5 subEna running W
6 subEna Value W(R) R W
7 GI ok W W
1 Quality Code R W R W W
2 0 subVal Bit 0 Ersatzwert 1 oder 2 bits W(R) R
1 subVal Bit 1 W(R) R
2 subError If subs had error W
3 Ack Enabled R R
4 Ack Request W W
5 Ack Response R R
6 reserved
7 Local/Remote Local/Remote Info for R
60870.
3 subQ Ersatz Quality- Wert W(R) R
4-11 Timestamp S7 Time, UTC Time R W R W W
Zone.
Tabelle 1: Read Only Binary/4States Value (12 Bytes)

Byte Bit Name Beschreiung Server Clt Slv Master DP


0-3 Value INT32 oder Float R W R W W
4 0 Ack Enabled R R
1 Ack Request W W
2 Ack Response R R
3 subError If subs had error W
4 subEna Trigger Substitue Enabled Trigger R
5 subEna running subVal wird geschrieben W
6 subEna Value W(R) R
7 GI ok W W
5 Quality Code R W R W W
6-9 subVal Ersatzwert INT32 oder Float W(R) R
10 subQ Ersatz Quality- Wert W(R) R
11 reserved
12-19 Timestamp S7 Time, UTC Time Zone. R W R W W
Tabelle 2: Read Only 4 Bytes Value (20 Bytes)

Byte Name Beschreibung Server Clt Slv Master DP


0-X Value Hier ist der Wert (Big Endian) abgespeichert, R W R W -
bis zu X Bytes.
Tabelle 3: Generic Read

Byte Bit Name Beschreibung Server Clt Slv Master DP


0 0 reserved -
1 reserved -
2 reserved -
3 reserved -
4 Trigger R R -
5 Running W W -
6 Stored error W W -
7 Wrong mode W W -
1 Error code W W -
1 0 LostIndication Lost Frame Indication W
1 LostAck Lost Frame Indication Ack R
2 Bad Quality Geschriebe Variable hat BadQuality W
2-X Value Hier ist der Wert (Big Endian) W(R) R W R -
abgespeichert, bis zu X Bytes,
welche vom Client an Server
geschrieben werden soll.
Tabelle 4: Generic Write
Byte Bit Name Beschreibung Server Clt Slv Master DP
0 0 Value Bit 0 Wert für Single Point oder W(R) R W R R
Double Point
1 Value Bit 1 Wert für Double Point W(R) R W R
2 Test W(R) R W R
3 Disabled Steuerung Erlaubt (0) / nicht R R
erlaubt (1)
4 Trigger S7 Trigger um Kommando R R
zu schreiben
5 Running Kommando wird schon W W
ausgeführt
6 Stored error “Error code”- Byte hat W W
Fehlerbeschreibung
7 Wrong mode (E.g. not connected) W W
1 Error code W W W
1 0 LostIndication Lost Frame Indication W
1 LostAck Lost Frame Indication Ack R
2 Bad Quality Geschriebe Variable hat W
BadQuality
3 Interop Control mit Interop Flag W(R)
4 Synchrocheck Control mit Synchrocheck W(R)
Flag
2-3 OriginID 16 bit integer R R R R
4-11 Timestamp S7 Time, UTC Time Zone. W(R) W R W
Tabelle 5: Control Binary / 4 States Value (12 Bytes)

Byte Bit Name Beschreiung Server Clt Slv Master DP


0 0 reserved
1 reserved
2 Test W R W R
3 Disabled Steuerung Erlaubt (0) / nicht erlaubt R R
(1)
4 Trigger S7 Trigger um Kommando zu R R
schreiben
5 Running Kommando wird schon ausgeführt W W
6 Stored error “Error code”- Byte hat W W
Fehlerbeschreibung
7 Wrong mode (E.g. not connected) W W
1 Error code W W W
1 0 LostIndication Lost Frame Indication W
1 LostAck Lost Frame Indication Ack R
2 Bad Quality Geschriebe Variable hat BadQuality W
3 Interop Control mit Interop Flag W
4 Synchrocheck Control mit Synchrocheck Flag W
2-3 Origin 16 bit integer R R R R
4-11 Timestamp S7 Time, UTC Time Zone. W(R) W R
12-15 Value 32 Bits für Integer oder Float W(R) R W R R
Tabelle 6: Control Integer, Float Value (16 Bytes)
Byte Bit Name Beschreiung Server Clt Slv Master DP
0-3 Value Float/Integer R W
4 0 Ack Enabled R R
1 Ack Request W W
2 Ack Response R R
3 reserved
4 reserved Substitue Enabled Trigger
5 reserved subVal wird geschrieben
6 reserved
7 GI ok W
5 Quality Code R W
6-9 reserved
10 reserved
11 reserved
12-19 Timestamp S7 Time, UTC Time Zone. R W
20-23 Low range Float R R
24-27 High range Float R R

Tabelle 7: Scaled/Normalized Status (28 bytes)

Byte Bit Name Beschreiung Ser Clt Slv Maste DP


ver r
0 0 reserved
1 reserved
2 Test W(R) R
3 Disabled Steuerung Erlaubt (0) / nicht erlaubt(1) R R
4 Trigger R
5 Running Kommando wird schon ausgeführt W
6 Stored error “Error code”- Byte hat W
Fehlerbeschreibung
7 Wrong mode (E.g. not connected) W
1 Error code W
1 0 LostIndication Lost Frame Indication
1 LostAck Lost Frame Indication Ack
2 Bad Quality Geschriebe Variable hat BadQuality
2 Reserved Platzhalter
3 Origin 8 bit integer R R
4-11 Timestamp S7 Time, UTC Time Zone. W(R) R
12-15 Value Float / Integer W(R) R
16-19 Low range Float R R
20-23 High range Float R R

Tabelle 8: Scaled/Normalized Control (24 Bytes)


Byte Bit Name Srv Clt Slv Mst DP
0 0 Connected link 0 W W W W R
1 Connected link 1 W W W
2 Active link 0 W W W W R
3 Active link 1 W W W
4 Redundant switch over active W W W W
5 Disconnected, timeout W W W W
6 Disconnected, timeout life bit W W W W
7 Redundancy trigger R* R* R* R*
1 0 Trigger GI R R
1 GI is active W W
2 GI timeout W W
3 Trigger Test telegram R
4 Test telegram running W
5 Test telegram result (0 ok, 1 Timeout) W
6 IEC Suggest redundancy switchover W* W* W* W*
7 Redundancy configured W
2-3 Origin für Ersatzwerten und Monitoring (60870 nur Byte 3) R R R R
4 Reserved
5 CommunicationType W W W W R
6-9 Partner Address of active link(IP, DP, etc.) W W W W R
10-11 SubAddress of active link(IP Port ,etc.) W W W W R
12-19 Timestamp last connect (A) W W W W R
20-27 Timestamp last disconnect (A) W W W W R
28-35 Timestamp last connect B W W W W W
36-43 Timestamp last disconnect B W W W W W
44-51 Last redundancy switchover W W W W R
Tabelle 9: Verbindung UDT (52 Bytes)
*Bit kann nur vom redundanten Master ausgewertet/gesetzt werden.

Wert Beschreibug
0 Undefiniert
1 60870 Master
2 60870 Slave
3 61850 Client
4 61850 Server
6 DP
Tabelle 10: Communication Types
Byte Bit Name IEC
0 0 Redundancy projected W
1 Role (Master/Stand-by) (1 – StandBy) W
2 Partner role (Master/Stand-by) (1 – StandBy) W
3 Partner connected over main connection W
4 Partner connected over secondary connection W
5 Trigger redundancy switchover R
6 Redundancy switchover active W
7 CPU Nummer (0 – CPU 0, 1 – CPU1)
1 0 IEC_CON_FAIL – Alle IEC connections (client/master) are lost on this W
device
1 IEC_CON_FAIL_P – All IEC connections (client/master)are lost on W
partner device
2 all IEC connections (client/master ) connected by this device W
3 all IEC connections (client/master)connected by partner W
4 Information all DP slaves are lost (OB86) R
5 Information all DP slaves are lost by Partner (OB86) W
6 Information all DP slaves are connected R
7 Information all DP slaves are connected by Partner W
2 0 Is synchronised W
1 Is Conn OK - If last data ex cycle in S7 was valid synchronised W
2-7 reserved
3 reserved
4-11 Timestamp of last red. switchover W
12-19 Timestamp of last connection establishment with redundancy partner W
20-27 Timestamp of last connection lost with redundancy partner W
28-31 Value of TIME_TCK R
32-35 Value of TIME_TCK (Partner) W
Tabelle 11: Redundanzmanager (36 Bytes)

Quality Name Quality bits in IEC60870 Quality bits in IEC61850 Quality bits in Profibus
(UDT) Bits DP
0 0x01 Blocked Blocked (BL) operatorBlocked -
1 0x02 Substitute Substituted (SB) substituted | process QSUBS vom
Treiberbaustein
2 0x04 Not actual Not- Topical (NT) oldData QLAST vom
Treiberbaustein
3 0x08 Invalid Invalid (IV) invalid | questionable -
4 0x10 Failure - failure Bit 1, 2, 3, 5 vom
DIAG_INF
5 0x20 Overflow / Overflow (CY / OV) overflow / outOfRange / Bit 0, 6, 7 vom
Inconsisten inconsistent (Analog DIAG_INF
t Overflow oder
outOfRange, Binaer
Inconsistent)
6 0x40 Test - test QSIM vom
Treiberbaustein
7 0x80 Wire break - - Bit 4 vom DIAG_INF

Folgende Bits warden nicht berücksichtigt


badReference
- oscillatory
- inconsistent
- inaccurate
Counter Adjusted (CA) -
Tabelle 12: Mapping zwischen Quality Bits von IEC60870, IEC61850 und Profbus