Driven H-Section Steel Pile Design / DIN1054:2005

INPUT:
Vertical Load: V ≔ -28.7 kN
[- compression / + tension]

Horizontal Load: H ≔ 38.36 kN

Bending Moment: My ≔ 440 kN ⋅ m

Fundament With: L ≔ 0.53 m

Fundament Length: B≔3 m B1 ≔ 0.35 m

Fundament Height: t ≔ 0.8 m

Pillar Heigth: tbf ≔ 0 m

Pile Engagement in teb.f ≔ 0.5 m


Fundament:
Pile Steel Grade: Gpr ≔ “S355”

Design Vertical Load: Vd = -60.5 kN 3 - 2 ⋅ 0.4 = 2.2

Design Bending Moment: My.d = 470.69 kN ⋅ m

Piles Loading Determination:

My.d Vd
Pile Profile A - Loading: FA.Ed ≔ ――― + ― = 174.4 kN (Tied Pile)
B - 2 ⋅ B1 2

My.d Vd
Pile Profile B - Loading: FB.Ed ≔ -――― + ― = -234.9 kN (Bearing Pile)
B - 2 ⋅ B1 2

BayWa r.e. AG | Arabellastraße 4 | 81925 München | Telefon: +49 89 383932-0 | Telefax: +49 89 383932-32
info@baywa-re.com | www.baywa-re.com | Vorstand: Matthias Taft (Vorsitzender), Günter Haug, Harald Wilbert
Aufsichtsratsvorsitzender: Prof. Klaus Josef Lutz | Sitz: München, Deutschland
Handelsregister: Amtsgericht München, HRB: 264823 | USt-IdNr.: DE 266 587 063 Page 1 of 6 Date 22/11/22
1. Check Pile Engagement in Fundament

Pile Profile Section Data: Ppr ≔ “HEA240”

hf ≔ 230 mm

bf ≔ 240 mm

2
m
Am ≔ 1.37 ――
m
kg
wt ≔ 60.3 ――
m

Concrete Fundament: Crt ≔ “C25/30”

N
fc.k ≔ 25 ――
2
mm

N
fbd ≔ 1.6 ――
2
mm

Allowable Loading: Nd.Rd ≔ fbd ⋅ teb.f ⋅ Am = 1096 kN

max ⎛⎝FA.Ed , ‖‖FB.Ed‖‖⎞⎠


Engagement in Concrete IR01 ≔ ――――――― = 0.21 Limit ≔ 1.00
Utilization: Nd.Rd

2. Soil Parameters
BayWa r.e. AG | Arabellastraße 4 | 81925 München | Telefon: +49 89 383932-0 | Telefax: +49 89 383932-32
info@baywa-re.com | www.baywa-re.com | Vorstand: Matthias Taft (Vorsitzender), Günter Haug, Harald Wilbert
Aufsichtsratsvorsitzender: Prof. Klaus Josef Lutz | Sitz: München, Deutschland
Handelsregister: Amtsgericht München, HRB: 264823 | USt-IdNr.: DE 266 587 063 Page 2 of 6 Date 22/11/22
2. Soil Parameters

- Layer 1: Gravel, qc ≥ 7,5MN/m2

- Layer 2: Sand, qc ≥ 15MN/m2

3. Compressed / Bearing Pile Check


BayWa r.e. AG | Arabellastraße 4 | 81925 München | Telefon: +49 89 383932-0 | Telefax: +49 89 383932-32
info@baywa-re.com | www.baywa-re.com | Vorstand: Matthias Taft (Vorsitzender), Günter Haug, Harald Wilbert
Aufsichtsratsvorsitzender: Prof. Klaus Josef Lutz | Sitz: München, Deutschland
Handelsregister: Amtsgericht München, HRB: 264823 | USt-IdNr.: DE 266 587 063 Page 3 of 6 Date 22/11/22
3. Compressed / Bearing Pile Check

Profile ≔ “HEA240”

Profile Heigth: hf ≔ 230 mm

Profile Width: bf ≔ 240 mm

2
Profile Section Area: Ab.k ≔ 76.8 cm

2
m
Profile Section Surface: As.k ≔ 1.37 ――
m

Layer 1 / Shaft Resitance: Layer 2 / Shaft Resitance:


Model Factor: ηs ≔ 0.6

Pile Length: L1 ≔ 1.7 m L2 ≔ 3.3 m

MN MN
CPT Cone Resitance: qc.L1 ≔ 7.5 ―― qc.L2 ≔ 15 ――
2 2
m m
kN kN
Pile Skin Friction: qs.k.10.L1 ≔ 60 ―― qs.k.10.L2 ≔ 125 ――
2 2
m m
2 2
Pile Skin Friction Area: As.L1 ≔ As.k ⋅ L1 = 2.3 m As.L2 ≔ As.k ⋅ L2 = 4.5 m

Char. Shaft Resistance: Rs.k.L1 ≔ qs.k.10.L1 ⋅ As.L1 = 139.7 kN Rs.k.L2 ≔ qs.k.10.L2 ⋅ As.L2 = 565.1 kN

Tot. Char. Shaft Res.: Rs.k ≔ ηs ⋅ ⎛⎝Rs.k.L1 + Rs.k.L2⎞⎠ = 422.9 kN Le.s ≔ L1 + L2 + teb.f = 5.5 m

Layer 2 / Base Resitance:

kN
Pile Base Resistance: qb.k.10 ≔ 10200 ――
2
m
2
Profile Section Area: Ab.k = 76.8 cm

hf
Model Factor: ηb ≔ 0.78 - 0.30 ⋅ ―= 0.5
bf

Char. Base Resistance: Rb.k ≔ qb.k.10 ⋅ Ab.k ⋅ ηb = 38.58 kN

Char. Compression Pile Rk ≔ Rb.k + Rs.k = 461.5 kN


Resistance:
Safety Factor: γp ≔ 1.4

Rk
Compression Pile Rd ≔ ― = 329.64 kN
Resistance: γp

‖‖FB.Ed‖‖
Compression Utilization: IR03 ≔ ――― = 0.71 Limit ≔ 1.00
Rd

BayWa r.e. AG | Arabellastraße 4 | 81925 München | Telefon: +49 89 383932-0 | Telefax: +49 89 383932-32
info@baywa-re.com | www.baywa-re.com | Vorstand: Matthias Taft (Vorsitzender), Günter Haug, Harald Wilbert
Aufsichtsratsvorsitzender: Prof. Klaus Josef Lutz | Sitz: München, Deutschland
Handelsregister: Amtsgericht München, HRB: 264823 | USt-IdNr.: DE 266 587 063 Page 4 of 6 Date 22/11/22
4. Compressed / Bearing Pile Settlement Check

Layer 1 / Shaft Resitance - Ssg*: Layer 2 / Shaft Resitance Ssg*:


Model Factor: ηs ≔ 0.6

Pile Length: L1 ≔ 1.7 m L2 ≔ 3.3 m

MN MN
CPT Cone Resitance: qc.L1 ≔ 7.5 ―― qc.L2 ≔ 15 ――
2 2
m m
kN kN
Pile Skin Friction: qs.k.10.L1 ≔ 40 ―― qs.k.10.L2 ≔ 90 ――
2 2
m m
2 2
Pile Skin Friction Area: As.L1 ≔ As.k ⋅ L1 = 2.3 m As.L2 ≔ As.k ⋅ L2 = 4.5 m

Char. Shaft Resistance: Rs.k.L1 ≔ qs.k.10.L1 ⋅ As.L1 = 93.2 kN Rs.k.L2 ≔ qs.k.10.L2 ⋅ As.L2 = 406.9 kN

Tot. Char. Shaft Res.: Rs.k.Ssg° ≔ ⎛⎝Rs.k.L1 + Rs.k.L2⎞⎠ = 0.5 MN

cm
ssg° ≔ 0.5 ⋅ Rs.k.Ssg° ⋅ ―― = 0.25 cm < ssg°.Limit ≔ 1.0 cm
MN

ssg°
Char. Settlement Check: IR04 ≔ ――― = 0.25 Limit ≔ 1.00
ssg°.Limit

5. Tensioned / Tied Pile Friction Check


kg
Pile Self-Weight: wt = 60.3 ――
m
kN
Pile Weight: Wp ≔ ⎛⎝L1 + L2⎞⎠ ⋅ wt ⋅ ――― ⋅ 1.35 = 4.07 kN
100 kg

Pile Loading: FA.Ed.w ≔ FA.Ed - 0.9 ⋅ Wp = 170.73 kN

Tot. Char. Shaft Res.: Rs.k ≔ ηs ⋅ ⎛⎝Rs.k.L1 + Rs.k.L2⎞⎠ = 300.03 kN

Char. Friction Pile Rk ≔ Rs.k = 300.03 kN


Resistance:
Safety Factor: γp ≔ 1.4 γM ≔ 1.25

Rk
Tension Resistance: Rd.t ≔ ――― = 171.45 kN
γp ⋅ γM

FA.Ed.w
Tension Utilization: IR05 ≔ ――― = 0.996 Limit ≔ 1.00
Rd.t

BayWa r.e. AG | Arabellastraße 4 | 81925 München | Telefon: +49 89 383932-0 | Telefax: +49 89 383932-32
info@baywa-re.com | www.baywa-re.com | Vorstand: Matthias Taft (Vorsitzender), Günter Haug, Harald Wilbert
Aufsichtsratsvorsitzender: Prof. Klaus Josef Lutz | Sitz: München, Deutschland
Handelsregister: Amtsgericht München, HRB: 264823 | USt-IdNr.: DE 266 587 063 Page 5 of 6 Date 22/11/22
Results Summary:

01. Engagement in Concrete IR01 = 0.2 Limit ≔ 1.00


Utilization:
03. Compression Utilization: IR03 = 0.7 Limit ≔ 1.00

04. Char. Settlement Check:: IR04 = 0.3 Limit ≔ 1.00

05. Tension Utilization: IR05 = 0.996 Limit ≔ 1.00

06. Pile Engagement Length in Profile = “HEA240” Le.s = 5.5 m


Soil and Profile:

BayWa r.e. AG | Arabellastraße 4 | 81925 München | Telefon: +49 89 383932-0 | Telefax: +49 89 383932-32
info@baywa-re.com | www.baywa-re.com | Vorstand: Matthias Taft (Vorsitzender), Günter Haug, Harald Wilbert
Aufsichtsratsvorsitzender: Prof. Klaus Josef Lutz | Sitz: München, Deutschland
Handelsregister: Amtsgericht München, HRB: 264823 | USt-IdNr.: DE 266 587 063 Page 6 of 6 Date 22/11/22

Das könnte Ihnen auch gefallen