WEATHER SYSTEM
Maker:  WALKER    
Model:  5002 WIND AND WEATHER 
1 2 3 4 5 6 7 8 9 10 11 12

A 76/11 A
WIND AND WEATHER SENSOR
P1003

P293 CABLE
ASSEMBLY
B L=40m B
P 293B

NMEA0183 + POWER

ANTENNA DECK

C C

BRIDGE CONSOLE
76/31 76/32
WIND SPEED AND DIRECTION INDICATOR P1249 WEATHER DATA DISPLAY P1255

7070 WALKER
WIND DATA
N

D 90 W
KPS
MPS
KTS

E 90
D
S

T/R L/T 180

CH1
NMEA0183
1 1
NMEA0183 INPUT
1 1 1 1 1
OUTPUT 1 1 1
NMEA0183 INPUT
1 1

1 1 1 1 1 1 1 1 1 1 1 1

V+ V- A B A B SCN V+ V- A B SCN

24V DC
0V DC

76/31 CH1 B
76/31 CH1 A
76/03.L1.5
76/03.L1.6
76/03.L1.7
76/03.L1.8

76/32.B
76/32.A
E E

NMEA0183 (YS)
2CORE SCREEN

24V DC
2X2.5 (YS)

76/31.V+
76/31.V-

76/31.B
76/31.A
24V DC
0V DC

F F
1 1 1 1 1 1 1 1 1 1

76/03.L1
1 1 1 1 1 1 1 1 1 1

1 2 3 4 5 6 7 8 9 10
GRN
24V DC
0V DC

RED
BLUE
YEL
FUER DIESES DOKUMENT BEHALTEN WIR UNS ALLE RECHTE VOR.
FOR THIS DOCUMENT ALL RIGHTS RESERVED.

G G

10A
2X2.5 (YS)
24V DC FEEDING FROM 76002
MAIN & EMERGENCY
SOURCE OF POWER

H NAME DATE H
KABEL- UND ANSCHLUSSPLAN CABLE AND CONNECTION DIAGRAM
DRAWN AN 03.09.2018
CHECK James 03.09.2018 WEATHER SYSTEM WEATHER SYSTEM 76-CA/CO-D-18LoR01301-C SHEET 1
INDEX MODIFICATION DATE NAME NORM PT ARUNG KARUNIA SEJATI PROJECT: LST AT5,AT6,AT7 1 SHEETS
1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12

A
ANMERKUNGEN / REMARKS A

DER KABELTYP RICHTET SICH NACH DER KLASSIFIKATIONSVORSCHRIFT.


THE TYPE OF CABLE CONFORMS TO RULES OF CLASSIFICATION AUTHORITY.

ALLE ANGABEN ZU ADERQUERSCHNITTEN SIND RAYTHEON-MINDESTANFORDERUNGEN.


DIE ANGABEN IN DEN VORSCHRIFTEN DER JEWEILIGEN KLASSIFIKATIONSGESELLSCHAFT
SIND JEDOCH ZU BERUECKSICHTIGEN.
ALL CORE CROSS SPECIFICATIONS ARE MINIMUM RAYTHEON REQUESTS.
BUT TAKE INTO CONSIDERATION THE SPECIFICATIONS OF THE RULES OF CURRECT
CLASSIFICATION AUTHORITY.

B ALLE KABEL SIND ABGESCHIRMT / KUPFERDRAHT-GEFLECHT.


B
ALL CABLES ARE SHIELDED / COPPER WIRE MESH.

ALLE KABELANGABEN OHNE RESERVEADERN.


ALL CABLES INDICATED WITHOUT SPARE CORES.

KABEL SIND UNTER DECK VERLEGT.


ENERGIE- UND BELEUCHTUNGSKABEL SIND GETRENNT VON SIGNALKABELN VERLEGT.
CABLES TO BE INSTALLED INDOOR. CABLES FOR POWER SUPPLY AND ILLUMINATION
TO BE SEPARATED FROM CABLES FOR SIGNALLING / MONITORING.

C VERBINDLICHE ERDUNGSMASSNAHMEN, SIEHE JEWEILIGES INSTALLATIONSHANDBUCH. C


THE INSTALLATION MANUALS ARE BINDING FOR GROUNDING INSTRUCTIONS.
76/11 WIND AND WEATHER SENSOR WIND AND WEATHER SENSOR P296
76/31 WIND SPEED AND DIRECTION INDICATOR WIND SPEED AND DIRECTION INDICATOR P1249
76/32 WEATHER DATA DISPLAY WEATHER DATA DISPLAY P1255 NICHT RAYTHEON-LIEFERUNG.
76/03.L1 TERMINAL STRIPS TERMINAL STRIPS YARD SUPPLY NOT SUPPLIED BY RAYTHEON.

KABELSTAEMME SIND GETRENNT VERLEGT.


CABLE-LOOMS ARE LAID SEPARATELY.

ZU VERWENDENDE ADER: 1.0mm², SW


USE CORE: 1.0mm², BK

D D
ADERQUERSCHNITT IST ABHAENGIG VON DER KABELLAENGE, SPANNUNGSABFALL <= 6%.
CORE CROSS SECTION ACCORDING TO CABLE LENGTH, VOLTAGE DROP <= 6%.

EINSPEISUNG VOM BATTERIEGEPUFFERTEN NOTNETZ.


FEEDING FROM BATTERY BUFFERED EMERGENCY SOURCE OF POWER.

ANSCHLUSSMOEGLICHKEIT FUER EXT. SIGNALTABLEAU.


CONNECTION POSSIBILITY FOR EXT. SIGNAL PANEL.

RAYTHEON-LIEFERUNG, LAENGE
E E
RAYTHEON-SUPPLY, LENGTH

KABELEINFUEHRUNG AUS METALL MIT AUFNAHME-KONUS FUER SCHIRM (EMV).


METALLIC CABLE-GLAND WITH CONNECTOR FOR SCREEN (EMC).

KABEL DURCH DEN FERRITKERN SCHLEIFEN!


FERRITKERN MUSS NAHE DER KABELEINFUEHRUNG BEFESTIGT WERDEN!
LOOP CABLE AROUND FERRITIC SLEEVE!
SLEEVE MUST BE LOCATED CLOSE TO CABLE GLAND!

F ANSCHLUESSE ZUM VDR:


F
SIGNALE ZUM VDR MUESSEN POTENTIALFREI ODER UEBER ISOLATIONSVERSTAERKER /
OPTOKOPPLER GALVANISCH GETRENNT UND RUECKWIRKUNGSFREI UEBERTRAGEN WERDEN.
DIE ENTKOPPLUNG HAT AM UEBERGABEPUNKT ZU ERFOLGEN. DER VDR-HERSTELLER IST
VERANTWORTLICH FUER DIE VOLLSTAENDIGE EINHALTUNG DER RELEVANTEN VORSCHRIFTEN.
FUER DIESES DOKUMENT BEHALTEN WIR UNS ALLE RECHTE VOR.

CONNECTIONS TO VDR:
SIGNALS TO THE VDR MUST BE TRANSMITTED POTENTIAL FREE OR GALVANICALLY
INSULATED VIA INSULATION AMPLIFIERS / OPTOCOUPLERS REACTION-FREE FROM
THE DESIGNATED CONNECTION POINTS. THE VDR MANUFACTURER IS RESPONSIBLE FOR
FULL COMPLIANCE WITH RELEVANT REGULATIONS.
FOR THIS DOCUMENT ALL RIGHTS RESERVED.

! ANSCHLUSS AM SIGNALTABLEAU IST ZWINGEND ERFORDERLICH.


G CONNECTION TO SIGNAL PANEL IS MANDATORY. G

END TERMINATION OF CAN BUS:


INSERT JUMPERS B13 AND B16 AT OPERATOR UNIT.
INSERT JUMPERS B31 AND B32 AT GYRO.

GESCHIRMTE, PAARIG VERDRILLTE KABEL VERWENDEN! (2X2X0.75). FUER CAN-BUS VERBINDUNGEN MAX. LAENGE= 400m.
USE SCREENED TWISTED PAIR CABLE! (2X2X0.75). FOR CAN-BUS CONNECTIONS MAX. LENGTH= 400m.

(YS) YARD SUPPLY

H NAME DATE H
LEGENDE LEGEND
DRAWN AN 03.09.2018
CHECK James 03.09.2018 WEATHER SYSTEM WEATHER SYSTEM 76-LE-D-18LoR01301-C SHEET 1
INDEX MODIFICATION DATE NAME NORM PT ARUNG KARUNIA SEJATI PROJECT: LST AT5,AT6,AT7 1 SHEETS
1 2 3 4 5 6 7 8 9 10 11 12