Sie sind auf Seite 1von 12

HydroFixx

The Manifold with integrated Hydraulic Separator

heating & cooling systems

Sinus
HydroFixx
Sinus
HydroFixx
Success
of an einer
Innovation
Der Erfolg
Innovation
The Sinus HydroFixx is among the most innovative
systems in hot water distribution because its
functioning
is proven scientifically
and there
are many
Durch die wissenschaftliche
Belegbarkeit
der Funktion,
thousands
of
flawless
working
systems
in
operation
sowie aufgrund vieler tausend tadellos funktionierender
Anlagen europaweit,
gehrtthings
der Sinus
HydroFixx
mit The
zu
throughout
Europe. Good
can be
so simple.
den innovativsten
der HeizungswasserverteiSinus
HydroFixx Neuerungen
has been improved
continually over
lung. Gutes kann so einfach sein.
the
years. While the Sinus HydroFixx was installed in
Im Laufe der Jahre wurde der Sinus HydroFixx permanent
small plants of up to 50 kW years ago, nowadays plants
weiterentwickelt. Wurden vor Jahren noch Kleinanlagen
with
output
of over
2 MWausgestattet,
run perfectly
via aheutSinus
bis 50ankW
mit Sinus
HydroFixx
laufen

HydroFixx. Optimum water distribution, flawless


hydraulic decoupling, an optional Tichelmann-type
connection
system and heating
circuits
right nextEntto
Optimale
Wasserverteilung,
tadellose
hydraulische
one
another
in
a
space-saving
configuration
are
just
kopplung, zudem ein mgliches Anbindungssystem nach
Tichelmann
bei that
direkt
und platzsparend
a few features
speak
in favour of neben
using einander
a Sinus
angeordneten
Heizkreisen
sind nur is
einige
die fr
HydroFixx. The
Sinus HydroFixx
suchAspekte
a trailblazing
den Einsatz des Sinus HydroFixx sprechen.
design that it was awarded the Innovation Prize of
Die Entwicklung des Sinus HydroFixx ist so bahnbrechend,
the State of North Rhine Westphalia.

dass sie mit dem Innovationspreis des Landes NRW ausgezeichnet wurde.

zutage Anlagen mit einer Leistung ber 10 MW einwandfrei ber den Sinus HydroFixx.

Subject to technical modifications

heating & cooling systems

HydroFixx The manifold with integrated Hydraulic separator

Your advantages
at a glance

Space advantage: small construction

Super compact design with hydraulic separator


placed horizontally under the manifold.
Optimum hydraulic decoupling between primary
and secondary circuits by upstream junction.
Very low space requirement.
No hydraulic problems with multiple heating
circuits.
Extremely short assembly time as no
pipework is required between the
conventional junction and the manifolds.
Compatible with all condensing appliances,
types and brands.

Manifold with separate


Hydraulic separator

Space advantage: large construction

Manifold with separate


Hydraulic separator

Subject to technical modifications

HydroFixx

heating & cooling systems

HydroFixx

Functions
Layout
It is a compact unit combining the advantages of the
space-saving heating circuit arrangement of a compact
manifold with the functionality of a hydraulic separator.
The Sinus manifold features two consecutive flow and
return chambers separated by a sinusoidal parting wall.
At the Sinus HydroFixx, two openings of the subjacent
hydraulic separator lead into the aforementioned
chambers. Since these openings are situated close
to the end caps of the junction body, the hydraulic
separators entire water content can be used as a
buffer volume for longer response times of the control
system at the hydraulic balancing.
The essentail function of hydraulic separators in
heating systems is to ensure the hydraulic decoupling
between the boiler circuit and the consumer circuit(s).
In particular, if the volume flows of the heat consumers
and heat generator(s) are of different sizes, hydraulic
separators are the ideal solution in order to eliminate
faulty hydraulic switching operations.
In vertically built-in hydraulic separators, temperature
stratification emerges due to the temperature
difference and, as a result, a difference in density. This
state continues as long as no admixing takes place.
However, the described phenomenon only occurs in
heating systems in full-load operation. Therefore, today,
temperature stratification is not placed at an increased
value. When using condensing
boilers, part of the return water is
Manifold
generally added to the secondary
flow in order to keep the boiler
Manifold
return temperature low for utilizing
the effect of condensation.

either vertically or horizontally without impairing


the main function of hydraulic decoupling. These
facts were taken as a basis for the Sinus HydroFixx
development and in turn designing a system
component which is highly flexible to install.
To operate the Sinus HydroFixx smoothly, it is
necessary to provide a requirement-specific
dimensioning of the base bodies and a proper
positioning of the inlet and outlet openings between
the junction and manifold. As with vertical hydraulic
separators, integrated junctions are designed in a way
that laminar flow conditions prevail. Consequently,
the cross-sectional area of the junction must be a
multiple of the feed pipe cross section. Observing
these criteria during the design phase ensures both
the smooth operation of the heating unit and the
flawless functioning of the hydraulic system.

return chamber
flow chamber

Hydraulic separator
As a consequence, the hydraulic
separator is always flown through
in by-pass operation preventing any thermal layering.
Accordingly, it is not imperative anymore to position the
hydraulic separator vertically as the force fields there
(buoyancy and gravitation force) cannot influence the
flow force due to the deliberate admission. Based on
that knowledge, hydraulic separators can be built in

Subject to technical modifications

heating & cooling systems

Product Line

The models in this performance class are designed for


quick mounting on standard
pump groups

The large version of HydroFixx is designed to match the


specific application. Customised construction types are
also possible

The MonoFixx can be used to


transform simple, small manifolds into hydraulic perfectionists! Optimum hydraulic
conditions are to be found in
all operating states.

The maintenance box enables


magnetite separation during
operation. Your heating
system will reward you with a
longer operating life!

Subject to technical modifications

Type

Flow
rate
in m/h

Connector
spacing
in mm

Capacity
at T 20 K
in kW

Boiler
connection

Heating Circuit
connection

Heating
circuits

80/80

3.0

125

70

1 external
thread

1
union nuts

2 to 4

120/80

7.0

125

160

2 external
thread

1
union nuts

2 to 4

Type

Flow
rate
in m/h

Connector
spacing
in mm

Capacity
at T 20 K
in kW

Boiler
connection

Heating Circuit
connection

Heating
circuits

120/120

7.0

200 or 250

160

DN 65

DN 50

from 2

160/160

10.8

250 or 300

250

DN 80

DN 65

from 2

180/180

17.2

250, 300, 350

400

DN 100

DN 80

from 2

200/200

25.8

250, 300, 350

600

DN 125

DN 100

from 2

280/320

53.8

300 or 350

1,250

DN 150

DN 125

from 2

300/350

68.8

300 or 350

1,600

DN 150

DN 125

from 2

400/400

90.0

variable

2,100

DN 150

DN 150

from 2

450/450

150.0

variable

3,500

DN 200

DN 200

from 2

500/550

194.0

variable

4,500

DN 250

DN 250

from 2

Type

Flow
rate
in m/h

Connector
spacing
in mm

Capacity
at T 20 K
in kW

Boiler
connection

Heating circuit
connection

80/80

3.0

125

70

1 external thread

1
union nuts

120/80

6.5

125

160

2 external thread

1
union nuts

Type

Flow
rate
in m/h

Operating
pressure

Operating
temperature

Connection

Suitable for

80/60

3.0

max. 4 bar

max. 110 C

2x G 1

HydroFixx 80/60 and


all small manifolds

120/80

7.0

max. 4 bar

max. 110 C

1x top Rp 2,
1x bottom R 2

HydroFixx 120/80 and


all small manifolds

heating & cooling systems

Perfect combination
HydroFixx with magnetite separation
Due to its large cross-section and the associated low
flow velocity, the HydroFixx is the ideal point for sludge
removal and magnetite separation. Only through the
consistent development of the HydroFixx models is it
now possible to combine more technology within one
component. Let your HydroFixx models take care of
reliability with the magnetite separation option. Your
heating system will reward you with a particularly long
operating life!
Dont settle for less!

Your advantages
at a glance
Hydraulics and sludge/magnetite separation
can be centrally combined within one
component
Save on costs as there is no need for additional
magnetite separation
Compact construction enables optimum use
of space
High reliability when operating your heating
system

Magnetite filter cartridge

Subject to technical modifications

heating & cooling systems

Fields of Application
The Sinus HydroFixx combines many positive features
in one component. Its integrated hydraulic separator
ensures optimum hydraulic decoupling of the boiler
circuit from the consumer circuits, and the Sinus
compact manifold placed horizontally above it offers a
space-saving configuration of the heating circuits.

flow adjustment. The Sinus HydroFixx records the


system supply temperature and compares it to the
boiler supply temperature. In this way, the volumetric
flow conditions in the hydraulic separator can be
inferred, and the speed of the integrated pump is
adjusted accordingly.

Developed for building services, especially for use


in single-boiler systems, the small-scale HydroFixx
is the optimum solution for combined and spacesaving heating circuit configurations. A system with
two or more heating circuits neither needs additional
installation resources nor additional space. Return
temperature increase is prevented if the condensing
unit has a junction control with primary-side volumetric

These advantages apply in particular to the largescale HydroFixx designs. Assembly time savings,
hydraulic decoupling, and minimised space
requirement have a particularly positive impact on
construction costs and plant efficiency. There are
several good reasons for combining the manifold
and the hydraulic separator.

Sinus HydroFixx, large construction for systems up to 9 MW

Subject to technical modifications

Sinus HydroFixx with two heating circuits

heating & cooling systems

SINUS
SINUS
HYDROFIXX
SINUSHYDROFIXX
HYDROFIXX

SINUS HYDROFIXX

Connection Options
5.3 Connection Options

5.3
5.3Connection
ConnectionOptions
Options

Additional
positive
featuresofofthe
theSinus
Sinus compact
compact
The medium
always flowsthrough
throughthe
themanifold
manifold in
in
Additional
positive
features
The
The
medium
always
flows
Additional
positive
features
Additional
positive
features of
of the
the Sinus
Sinus compact
compact
Themedium
mediumalways
alwaysflows
flowsthrough
throughthe
themanifold
manifoldinin
manifold
open up
a multitude
of connection
options.
cocurrent flow.Regular
Regular flow
flow rates
and thus
the
manifold
open
a amultitude
ofof
connection
options.
cocurrent flow.
flow.
rates
and
thus
the
manifold
openupup
connection
options.
flow. Regular
Regular flow
flowrates
ratesand
andthus
thusthe
the
manifold
up
amultitude
multitude
of
connection
options. it cocurrent
Toopen
operate
theboiler
Sinusflow
HydroFixx
smoothly,
iscocurrent
They
allow
placing
the
and
return
lines
availability
of
heating
water
are
guaranteed
availability
They
allow
placing
the
boiler
flow
and
return
lines
They
allow
placing
the
boiler
flow
and
return
lines
availability
of
heating
water
are
guaranteed
availability of
of heating
heating water
water are
are guaranteed
guaranteed
They
allow
placing
the
boiler
flow
and
return
lines
necessary
to provide
a each
requirement-specific
from below
or alternately
next to
other or at
throughout the system. Therefore, a Tichelmannthroughout
from
below
oror
alternately
next
toto
each
other
oror
from
below
alternately
next
each
other
throughout
the
system.
Therefore,
Tichelmannthroughoutthe
thesystem.
system.Therefore,
Therefore,aaaTichelmannTichelmannfrom
below
or
alternately
next
to
each
other
oratat
at
dimensioning
of the
bodies
and a proper type connection can also be applied.
both ends
of the manifold.
In allbase
events,
optimum
both
ends
ofof
the
manifold.
InInIn
allall
events,
type
connection
both
ends
the
manifold.
events,
optimum
type
connection
can
also
be
applied.
both
ends
of
the
manifold.
all
events,optimum
optimum
type
connectioncan
canalso
alsobe
beapplied.
applied.
positioning
of
the
inlet
and
outlet
openings
between
hydraulic decoupling is warranted.
hydraulic
decoupling
isisis
warranted.
hydraulic
decoupling
warranted.
hydraulic
decoupling
warranted.
the junction and manifold.
As with vertical
hydronic
junctions, integrated junctions
Boiler
flow
Boiler
flow
Boiler
flow
Boiler
flow
are designed in a way that laminar flow conditions
prevail. Consequently, the cross-sectional area of
Boiler
Boiler
Boiler
Boiler
return
return
return
the junction must be a multiple of the feed pipe
return
cross section. Observing these criteria during the
design phase ensures both the smooth operation of
Boiler
flow
Boiler
flow
flow
Boiler
flow
the heating unit and the flawless functioning of theBoiler
hydraulic system.

Boiler
flow
Boiler
flow
Boiler
flow
Boiler
flow

Boiler
Boiler
Boiler
Boiler
return
return
return
return

Boiler
return
Boiler
return
Boiler
return
Boiler
return

5.2 Configuration
6.
Multiple
Temperature
Zone
Applications
6.
Multiple
TemperatureZone
ZoneApplications
Applications
6.
Multiple
Temperature
Configuration
with
Multivalent
Heating
Systems
with
Multivalent
Heating
Systems
with
Heating
Systems
To provideMultivalent
optimum
functionality, the Sinus
HydroFixx
ensure
that predominantly laminar or steady flow
ensure that predominantly laminar or steady flow
To provide optimum functionality, the Sinus HydroFixx

must comply with certain design criteria. Of primary


conditions with low pressure loss prevail even under
conditions with low pressure loss prevail even under
must comply with certain design criteria. Of primary
The
increasing
number
of
multivalent
system
with
heat
pump
Theincreasing
increasing
number
ofmultivalent
multivalent
system
withaaaheat
heat
pumpon
onthe
thegeneration
generationside
sideor
oraaCHP
CHP
importance
is the correct
dimensioning
of the junction
full load.
The
number
full load. pump on the generation side or a CHP
importance is the
correctofdimensioning
ofsystem
the junction with
types
characterized
by
differently
tempered
(combined
heat
and
power
plant)
with
peak
load
typescharacterized
characterized
bydifferently
differently
tempered
(combinedheat
heatand
andpower
powerplant)
plant)with
withaaapeak
peakload
load
body
and the chamber
sizing resulting
therefrom (combined
to
types
by
tempered
body and the chamber sizing resulting therefrom to
generators/consumers
places
high
demands
on
boiler
is
to
supply
the
necessary
heat,
the
Sinus
HydroFixx
generators/consumers
places
high
demands
on
boiler
is
to
supply
the
necessary
heat,
the
Sinus
HydroFixx
generators/consumers places high demands on
boiler is to supply the necessary heat, the Sinus HydroFixx
the
management
the
medium.
Various
temperature
isisthe
Optimum
thermal
and
the
management
of
the
medium.
Various
temperature
thebest
bestchoice.
choice.Optimum
Optimumthermal
thermaland
andhydraulic
hydraulic
the
management
ofof
the
medium.
Various
temperature
Secondary heating circuit is1 the best choice.
Secondary heating
circuit 2hydraulic
levels
are
to
be
used
as
effectively
as
possible
functionality
of
the
system
is
achieved
through
levels
are
to
be
used
as
effectively
as
possible
functionality
of
the
system
is
achieved
through
levels are to be used as effectively as possible
functionality of the system is achieved through aaa
[m/s]
where
required.
Pressure
losses
need
be
minimized.
proper,
temperature-dependent
arrangement
of
the
where
required.
Pressure
losses
need
to
be
minimized.
proper,
temperature-dependentarrangement
arrangementof
ofthe
the
where
required.
Pressure
losses
need
toto
be
minimized.
proper,
temperature-dependent
1.5
Whenever
condensing
boilers
are
used
in
combination
connectors
of
both
heat
generators
and
consumers.
Whenever
condensing
boilers
are
used
in
combination
connectors
of
both
heat
generators
and
consumers.
Whenever condensing boilers are used in combination
connectors of both heat generators and consumers.
Feed
Feed
Feed
(CHP)
(CHP)
(CHP)
(70/50)
(70/50)
(70/50)

Feed
Feed
Feed
(Calorific
value)
(Calorific
value)
(Calorific value)
(65/45)
(65/45)
(65/45)

Static
heating
Static
heating1 1
Static heating 1
(60/40)
(60/40)
(60/40)

Static
heating
2 2
Static
heating
Static heating 2
(60/40)
(60/40)
(60/40)

Floor
heating
1 1
Floor
heating
Floor heating 1
(45/35)
(45/35)
(45/35)

Floor
heating
Floor
heating2 2
Floor heating 2
(45/35)
(45/35)
(45/35)

1.0

0.5
Sinus
Hydrofixx
Sinus
Hydrofixx
Sinus Hydrofixx

CHP
CHP
CHP

Condensing
Condensing
Condensing
boiler
boiler
boiler

0.0

CHP
with
peak
load
boiler
CHPwith
withpeak
peakload
loadboiler
boiler
CHP
on
the
primary
side,
on
the
primary
side,
on the primary side,
heating
circuits
with
heatingcircuits
circuitswith
with
heating
different
temperature
differenttemperature
temperature
different
levels
(static
heating,
levels
(static
heating,
levels (static heating,
floor
heating)
on
the
floor
heating)
onthe
the
floor heating) on
secondary
side
secondary
side
secondary side

Central cross-section of the


velocity vectors
Primary heating circuit

Subject to technical modifications

heating & cooling systems

999

HydroFixx

SINUS HYDROFIXX

Rcklauf
und Vorlaufstrom
knnen
der Hydraulischen
Flow
and -return
may converge
in the in
hydraulic
separator
Flow
and
return
may
converge
in
the
hydronic
junction
Weiche
zusammenlaufen,
ohne
dass
sich
die
Kreislufe
without any interference of the circuits. The
charts
gegenseitig
beeinflussen.
without
any
interference
of
the
circuits.
below show the appropriate sizes for particular water
flow rates and heat capacities.
Die unteren
Diagramme
die jeweils geeignete
BauThe
charts below
showzeigen
the appropriate
sizes for
gre
fr
den
entsprechenden
Wasserdurchsatz
bzw.
die
particular water flow rates and heat capacities.
Inentsprechende
the capacityWrmeleistung.
range < 7 m/h, prefabricated components are available which can be equipped with all
In the capacity range < 7m/h, prefabricated
Im Leistungsbereich
< 7m/h
kann5,auf
fertige
Bauteile
standard
pumpare
groups
(see which
page
topbe
figure).
components
available
can
equipped
zurckgegriffen werden, welche mit allen Standard-

with
all standard pump groups (see page 4, left figure).
Pumpengruppen bestckt werden knnen (Siehe Seite
In the capacity range > 7 m/h, the connector arrange5 oben).
ments
the heating
circuits
are made
according to
In the of
capacity
range
> 7m/h,
the connector
arrangements
heating
are made
local
conditions of
and
requirements
that the
Im Leistungsbereich
>the
7m/h
werdencircuits
dieensuring
Stutzenanordnunaccording
to local
conditions
and integrated
requirements
gen der
Heizkreise
gem.
Mglichkeiten
und Vorgaben
Sinus
HydroFixx
can
bederoptimally
in the
der
rtlichen
Gegebenheiten
vor
ge
nom
men,
sodass
der
Siensuring
that
the
Sinus
HydroFixx
can
be
optimally
boiler room as a space-saving junction unit.
nus HydroFixx
als platzsparende
-Weicheneinheit
integrated
in the
boiler room Verteiler
as a space-saving
optimal im
Heizungsraum integriert werden kann.
junction
unit.

WaterWasserdurchsatz
flow rate [m3/h][m3/h]

Auswahldiagramm Sinus HydroFixx

30Sinus

HydroFixx Selection Chart


T = 5 K

30

T = 5 K

120

T = 15 K

T = 10 K

120

T = 15 K
T = 20 K

T = 10 K

Sinus
HydroFixx
200/200

25
T = 20 K

25

Sinus
HydroFixx
200/200

20

T = 5 K

T = 15 K

T = 10 K

T = 15 K
T = 20 K

T = 10 K

100
Sinus
HydroFixx
400/400

T = 20 K

100

Sinus
HydroFixx
400/400
Sinus
HydroFixx
300/350

80
Sinus
HydroFixx
180/180

20

Sinus
HydroFixx
180/180

15
15

80

Sinus
HydroFixx
300/350

60
60

Sinus
HydroFixx
160/160

10

Sinus
Sinus
HydroFixx
HydroFixx
160/160
120/120

10

Sinus
HydroFixx
Sinus
120/120
HydroFixx
80/80

5
5

0
0

T = 5 K

75
75

150
150

225
225

300
300

375
375

450
450

525
525

40
40

20
20

Sinus
HydroFixx
80/80

600
600

500
500

1.000
1,000

1.500

2.000

2.500

Wrmeleistung
1,500
2,000 2,500

3.000

[kW]
3,000

Heat capacity [kW]

Subject to technical modifications

heating & cooling


systems
heating
& cooling systems

hydraulic decoupling is warranted.

Boiler flow

Boiler flow
Boiler
return
Boiler
return

Application

Boiler flow

Multiple Temperature Zone Applications


with Multivalent Heating Systems
Boiler return

6. Multiple Temperature (combined


ZoneheatApplications
and power plant) with a peak load
boiler is to supply the necessary heat, the Sinus
with Multivalent Heating
Systems
HydroFixx is the best choice.

The increasing number of multivalent system types


characterized by differently tempered generators/
consumers places high demands on the management
of the medium. Various temperature levels are to be
The as
increasing
of multivalent
system
used
effectivelynumber
as possible
where required.
Pressure
types characterized by differently tempered
losses need to be minimized. Whenever condensing
generators/consumers places high demands on
boilers are used in combination with a heat pump on
the management of the medium. Various temperature
the generation side or a CHP
levels are to be used as effectively as possible
where required. Pressure losses need to be minimized.
Whenever condensing boilers are used in combination
Feed
(CHP)
(70/50)

Feed
(Calorific value)
(65/45)

Static heating 1
(60/40)

Optimum thermal and hydraulic functionality of the

with a heat pump on the generation side or a CHP


system is achieved through a proper, temperature(combined heat and power plant) with a peak load
dependent arrangement of the connectors of both
boiler is to supply the necessary heat, the Sinus HydroFixx
heat generators and consumers.
is the best choice. Optimum thermal and hydraulic
functionality of the system is achieved through a
proper, temperature-dependent arrangement of the
connectors of both heat generators and consumers.

Static heating 2
(60/40)

Floor heating 1
(45/35)

Floor heating 2
(45/35)

CHP with peak load boiler


onCHP
thewith
primary
side,boiler on the
peak load
heating
circuits
with circuits
primary side, heating
different
temperature
with different temperature
levels
levels(static
(staticheating,
heating, floor
floor
heating)
onsecondary
the
heating) on the
side
secondary side

Sinus Hydrofixx

CHP

Condensing
boiler

SINUS HYDROFIXX

Feed
(Calorific value)
(60/40)

Feed
(Solar energy plant)
(60/40)

Static heating 1
(60/40)

Static heating 2
(60/40)

Floor heating 1
(45/35)

Floor heating 2
(45/35)

Condensing boiler combined


with solar energy plant on the
primary side, heating
circuits with different
temperature levels (static
heating, floor heating) on the
secondary side
Sinus Hydrofixx
Solar energy plant

Condensing
boiler

10

Subject to technical modifications

Condensing boiler combined with solar energy plan


circuits with different temperature levels (static h
secondary side

Feed
(Solar energy plant)
(65/40)

heating & cooling systems


Feed
(Calorific value)
(65/40)

Feed
(Heat pump)
(45/35)

Static heating 1
(55/35)

Static heating 2
(55/35)

Floor heating 1
(45/35)

Sinus Hydrofixx
Solar energy plant

Condensing boiler combined with solar energy plant on the primary side, h
circuits with different temperature levels (static heating, floor heating) o
secondary side

Condensing
boiler

Feed
(Calorific value)
(65/40)

Feed
(Solar energy plant)
(65/40)

Feed
(Heat pump)
(45/35)

Static heating 1
(55/35)

Static heating 2
(55/35)

Floor heating 1
(45/35)

Floor heating 2
(45/35)

SINUS HYDROFIXX

Sinus Hydrofixx
Peak load
boiler
Solar
energy
plant
(60/40)

Heat pump

Gas boiler

Condensing
boiler

Static heating 1
(60/40)

Static heating 2
(60/40)

Floor heating 1
(45/35)

Floor heating 2
(45/35)

Combination
of condensing
heat
solar energy plant on t
Combination of condensing
boiler, heatboiler,
pump and
solarpump
energy and
plant on
the primaryside,
side, heating
circuits
with different
levels (static heating,
primary
heating
circuits
with different
levels (static heating, floor
floor
heating)
on
the
secondary
side
on the secondary side
Feed flow (CHP)
(70/40)

Sinus HydroFixx optimum hydraulic conditions in all


modes of heating CHP
system
combinedoperation.
with buffer storage including nozzles and peak load boiler
Feed (CHP)
(70/40)

Charge/discharge
Sinus
HydroFixx
(buffer storage)
(65/40)

Static heating 1
(60/40)

Static heating 2
(60/40)

Floor heating 1
(45/35)

Floor heating 2
(45/35)

CHP

on the primary side, secondary heating circuits with different temperature


levels (static heating, floor heating)

Peak load boiler


(60/40)

Static heating 1
(60/40)

Static heating 2
(60/40)

Floor heating 1
(45/35)

Floor heating 2
(45/35)

Sinus HydroFixx
Gas boiler

Feed flow (CHP)


(70)

CHP

Einspeisung VL
(BHKW)
(35)

CHP and buffer battery with charge and discharge functio


the primary side, heating circuits with different temperat
levels (static heating, floor heating) on the secondary sid
Sinus HydroFixx

CHP

CHP with buffer battery and peak load boiler on the primary
CHP with buffer battery and peak load boiler on the primary
side, secondary heating circuits with different temperature
side, secondary heating circuits with different temperature
levels (static heating, floor heating)
levels (static heating, floor heating)

10

Sinus HydroFixx optimum hydraulic


conditions in all
modes of heating system
heating & cooling systems

Subject to technical modifications

11

SINUSVERTEILER GmbH
Dieselweg
2
SINUSVERTEILER
GmbH
D
- 48493 Wettringen
Dieselweg
2

D-48493+49
Wettringen
Telefon:
(0) 2557 / 93 93-0
Fax:
+49 (0) 2557 / 93 93-30
Phone: info@sinusverteiler.com
+49 (0) 2557 / 93 93-0
E-Mail:

Fax:
+49 (0) 2557 / 93 93-30
Email: info@sinusverteiler.com

Member of the Winkelmann Group