Table of contents
1.0 Detailled diagrams
3-6
2.0 Gas cooler.......................................................................................................................................... 7
3.0 Spare measuring modules ................................................................................................................. 8
4.0 Spare pcbs ......................................................................................................................................... 8
(0192 0518)
cover 1/ Abdeckung1
(0192 0516) (6x)
latch/ Riegel
(0192 0517)
latch/
Riegel
0440 0391
upper houseing part/
Gehuse-Oberteil
3
(0192 0537)
cover 2/
Abdeckung 2
brown/ braun
white/ weiss
yellow/ gelb
green/ gruen
0192 0530
protector/
Schutzleiste
(0449 0045)
lead/
Verbindungsleitung
0192 0504
Filter cover, clear/
Filtergehuse,
durchsichtig
0192 0514
filter cover,
black/
Flitergehuse,
schwarz
0135 0112
O-ring (3x)
pcb/ Platine
0470 0583
(350 M/XL,300 XXL)
0193 0074
grid/ Gitter
0470 0013
power supply
Netzteil
Dichtung
0239 0058 vane/ Lufter
0105 0179 (2x)
screws/ Schrauben.
0192 0532
pump holding device
Pumpenhalter
0105 0171 (2x) screw/Schraube
0192 0468
pump tool
Demontagewerkzeug
5
(Option 0440 0355)
0140 3541
label
Schild
Options:
0135 0111
O-Ring
0515.0098
rech.battery/
Akku
measuring modules/ Messzellen
6
0192 0393 cover/ Deckel
0140 3541 backside label/
Rckenschild
0135 0076 (3x) sealing/
Dichtung
O2
CO/H2
CO/H2
NO
NO2
HC
NOlow
CO/H2low
H2S
SO2
CO2 IR
Articlenumber
0390 0070
0390 0072
0390 0088
0390 0074
0390 0075
0390 0076
0390 0077
0390 0078
0390 0079
0390 0081
0390 0089***
***
The installation of an IR CO2 replacement module can be effected by service offices only.
The IR CO2 module has to be installed at the plug-in place No. 4.
The gas calibration data of the CO2 sensor are on the Eprom of the voltage supply PCB
(0460 0574). Because of this reason the voltage supply PCB has to be changed with the
change of the sensor module. The exchanged module is returned to the service office in
Lenzkirch together with the voltage supply PCB for checking warranty claims.
Spare pcb
testo
350M/XL, 300XXL
0470 0583
0470 0555
Attention:
When exchanging the main pcb (0470.0583) of flue gas analysers T 300XXL, T 350M/XL
please always remove the small additional pcb at socket Bu_61 from the old main pcb
and plug it to the new main pcb.
The firmware is already stored at the spare pcbs (0470.0583). In case of useing a spare pcb
(0470.0583) the firmware version has the be checked always and in case of an old version it
has to be updated.