APPENDIX “B” - LOW VOLTAGE MOTOR DATA SHEETS

LOW VOLTAGE (460 V) MOTOR DATA SHEETS (3 Sheets)

Vendor Name: ________________ Quotation No. ____________ Quote Date: _____________

Item Item Description


Design Requirements Vendor Confirmation
No.
0330-461-003 AM1
1 Motor No.
DE vendor to identify 0330-461-003-BM1
0330-461-004 AM1
2 Vendors Outline Dwg. No. Motor vendor to indicate E3007591
0330-461-003
3 Driven Equipment No.
DE vendor to specify 0330-461-003
0330-461-004
4 Driven Equipment Description DE vendor to specify Mercury Retort Furnace

5 Motor Manufacturer, Model No. Motor vendor to specify IEEE841 – 2001

6 Location (Indoor, Outdoor) DE vendor to specify

7 Area Classification (Class, Zone) DE vendor to specify

8 If Hazardous, indicate T-Rating Motor vendor to specify T3C 160°C

10 Enclosure Type (ODPFG, TEFC, XP, other) TEFC TEFC

11 Motor Type (squirrel cage, wound rotor) Squirrel Cage Squirrel Cage

12 Drive System (Direct, belt, chain, gear) DE vendor to specify

13 Operation (Fixed Speed, Variable, multi- DE vendor to specify


speed)
____ rpm (min) to
14 If Variable, indicate speed range DE vendor to specify
_____ rpm (max)
15 Preferred synchronous Speed 1800 rpm 1800 rpm

16 Full load speed Motor vendor to specify 1755 rpm

17 Duty Continuous Continuous


kW/Hp at 4 100 m ASL
18 Rating (at actual site elevation) DE vendor to specify
3.7 KW
19 Motor Frame Size Motor vendor to specify 184T

20

21 Volt, Phase, Hertz 460 V, 3 , 60 Hz 460/3/60

22 Service Factor 1.15 1.15

/conversion/tmp/activity_task_scratch/708565799.doc
Standard Specification Revision
Squirrel Cage Induction Motors
# Date Page
Low / Medium Voltage
Specification No.
01 2004-02-16 28
334344-0100-47EG-0002

LOW VOLTAGE (460 V) MOTOR DATA SHEETS (3 Sheets)

Vendor Name: ________________ Quotation No. ____________ Quote Date: _____________

Item Item Description


Design Requirements Vendor Confirmation
No.
23 Insulation Class NEMA Class F F

24 Insulation design voltage 1 600 V min 1600 V min

25 Temp. Rise (C)/Time Rating (sec) NEMA Class B NEMA Class B

26
DE vendor to specify method of
27 Starting Method (FV, RV, VFD)
starting
28 If Reduced Voltage, Type (Autotransf, Star DE vendor to specify type of
Delta, Resistor, Solid State) starter recommended

29 If Reduced Voltage, recommended % of full


Motor vendor to specify 80 %
voltage on starting

30 Starting Current @: ½L, ¾L, Full Load Motor Vendor to specify 4.16 5.15 6.40 A

31 Efficiency: ¾L, Full Load Vendor to specify 90.2 89.5

32 Power Factor: ¾L, Full Load Vendor to specify for 0.63 0.75 PF lag

33 Locked Rotor Current, A: Vendor to specify _49.9_A @ 100 % rated voltage


34
Torque Design Characteristics NEMA Design B NEMA Design B

35 Load Torque Requirements (constant, DE vendor to specify


variable)

36 Full Load Torque, (N·m) Motor Vendor to specify 20.05

37 Locked Rotor Torque, (N·m) Motor Vendor to specify 42.11

38 Allowable Wk2, (N·m) Motor Vendor to specify 0.6029

39 Allowable Time at locked rotor, sec DE vendor to specify

40 Permissible No. of Starts per Hour 2 minimum 2 cold, 1 hot

41

42 Operating Position (horiz, vert., other) DE vendor to specify

43 Mounting (foot, sliding base, flange, etc) DE vendor to specify

44 Common Driven Equipment Baseplate DE vendor to specify

45 Rotation (Viewed from NDE Shaft) DE vendor to specify

/conversion/tmp/activity_task_scratch/708565799.doc
Standard Specification Revision
Squirrel Cage Induction Motors
# Date Page
Low / Medium Voltage
Specification No.
01 2004-02-16 29
334344-0100-47EG-0002

LOW VOLTAGE (460 V) MOTOR DATA SHEETS (3 Sheets)

Vendor Name: ________________ Quotation No. ____________ Quote Date: _____________

Item Item Description


Design Requirements Vendor Confirmation
No.
Anti friction
46 Bearing: Type, Capacity (kg) Motor Vendor to specify
(DE – 10g / NDE – 5g)
47 Bearing Cat. No. (DE, ODE) Motor Vendor to specify 6307 6206

48 No. of Bearings Motor Vendor to specify 2

49 Bearing Lubrication system Motor Vendor to specify Grease


2 RTD’s / phase on motors
50 Winding Temperature Detection N/A
>187kW
All outdoor motors &
51 Space Heaters _____ W, _____V
all motors > 75 kW
52 Main Terminal Box Sized For:

53 - Motor Leads & terminations Motor Vendor to confirm Yes

54 - Surge Protection Motor Vendor to specify N/A

55 Vibration detection, specify DE Vendor to specify

56 Motor ventilation air filters provided Motor Vendor to confirm N/A

57 Ground Connections, number & location Motor Vendor to confirm 1 in Terminal Box

58 Weight, Kg Motor Vendor to confirm 45 kg


Motor Vendor to confirm, list
59 Tests Performed IEEE841-2001 Routine Test
below
60 Maximum Sound Level 80 dBA @ 1m 58 dBA @ 1m

61 Motors To Be Designed for Site Elevation


01 4100 m Above Sea Level Yes
of :

62 01 Bearing Temperature Detection Motor Vendor to confirm N/A

63

/conversion/tmp/activity_task_scratch/708565799.doc
Standard Specification Revision
Squirrel Cage Induction Motors
# Date Page
Low / Medium Voltage
Specification No.
01 2004-02-16 30
334344-0100-47EG-0002

LOW VOLTAGE (460 V) MOTOR DATA SHEETS (3 Sheets)

Vendor Name: ________________ Quotation No. ____________ Quote Date: _____________

Item Item Description


Design Requirements Vendor Confirmation
No.
Notes/Special Requirements/Remarks

1. DE means driven equipment

DOCUMENT END