Sie sind auf Seite 1von 13

Produkte

Products

Prfbericht - Nr.:
Test Report No.:




Seite 1 von 13
Page 1 of 13

Auftraggeber:
Client:
PH Technical Labs
1200 Commerce Dr, Suite #112, Plano, TX 75093.
Gegenstand der Prfung:
Test item:
Hot Watch
Bezeichnung:
Identification:
HOT0103
Serien-Nr.:
Serial No.:
Engineering Sample
Wareneingangs-Nr.:
Receipt No.:
1803033379-1-1
Eingangsdatum:
Date of receipt:
April 2014
Prfort:
Testing location:
Refer to section: Test Facilities


Prfgrundlage:
Test specification:


[Immunity]
EN 301 489-1 V1.9.2:2011
EN 301 489-17 V2.2.1:2012
EN 61000-4-2:2009 (contact: level 2 (4kV),(Air: level 3 (8kV))
EN 61000-4-3:2006+A2:2010 ( 80 - 1000)MHz, (1.4 - 2.7)GHz, level 2 (3V/m))



Prfergebnis:
Test Result:
Der Prfgegenstand entspricht oben genannter Prfgrundlage(n).
The test item passed the test specification(s).
Prflaboratorium:
Testing Laboratory:
TV Rheinland (India) Pvt. Ltd.
Plot No. 108, West Wing, Electronics City Phase 1, Hosur Road
Bangalore 560 100. India.

geprft/ tested by:

Un-Specified Written / Tested By / Inspector

Datum Name/Stellung Unterschrift
Date Name/Position Signature

kontrolliert/ reviewed by:

Un-Specified Checked By / Reviewer

Datum Name/Stellung Unterschrift
Date Name/Position Signature
Sonstiges / Other Aspects:

Abkrzungen: P(ass) = entspricht Prfgrundlage
F(ail) = entspricht nicht Prfgrundlage
N/A = nicht anwendbar
N/T = nicht getestet
Abbreviations: P(ass) = passed
F(ail) = failed
N/A = not applicable
N/T = not tested

Dieser Prfbericht bezieht sich nur auf das o.g. Prfmuster und darf ohne Genehmigung der Prfstelle nicht
auszugsweise vervielfltigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prfzeichens.
This test report relates to the a. m. test sample. Without permission of the test center this test report is not permitted to be
duplicated in extracts. This test report does not entitle to carry any safety mark on this or similar products.
TV Rheinland Product Safety GmbH Am Grauen Stein D - 51105 Kln Tel.: +49 221 806-1371 Fax: +49 221 806-3909
Mail: trps-certification@de.tuv.com Web: www.tuv.com Version: 2009-07-27





Produkte
Products

Prfbericht - Nr.:
Test Report No.:
Draft Report

Seite 2 von 13
Page 2 of 13


TEST SUMMARY

5.1.1 RADIATED RADIO-FREQUENCY ELECTROMAGNETIC FIELDS (RS)
RESULT: PASS
5.1.2 ELECTROSTATIC DISCHARGES (ESD)
RESULT: PASS





Produkte
Products

Prfbericht - Nr.:
Test Report No.:
Draft Report

Seite 3 von 13
Page 3 of 13


Contents
1. GENERAL REMARKS ............................................................................................... 4
1.1 COMPLEMENTARY MATERIALS ................................................................................. 4
2. TEST SITES ............................................................................................................ 4
2.1 TEST FACILITIES ..................................................................................................... 4
2.2 LIST OF TEST AND MEASUREMENT INSTRUMENTS ...................................................... 4
3. GENERAL PRODUCT INFORMATION ........................................................................... 5
3.1 PRODUCT FUNCTION AND INTENDED USE .................................................................. 5
3.2 RATINGS AND SYSTEM DETAILS ............................................................................... 5
3.3 INDEPENDENT OPERATION MODES ........................................................................... 5
3.4 NOISE GENERATING AND NOISE SUPPRESSING PARTS .............................................. 5
3.5 SUBMITTED DOCUMENTS ......................................................................................... 5
4. TEST SET-UP AND OPERATION MODES ..................................................................... 6
4.1 PRINCIPLE OF CONFIGURATION SELECTION ............................................................... 6
4.2 PHYSICAL CONFIGURATION FOR TESTING ................................................................. 6
4.3 TEST OPERATION AND TEST SOFTWARE ................................................................... 6
4.4 SPECIAL ACCESSORIES AND AUXILIARY EQUIPMENT ................................................. 6
4.5 COUNTERMEASURES TO ACHIEVE EMC COMPLIANCE ................................................ 6
5 . TEST RESULTS I MMU N I T Y ............................................................................. 7
5.1 CONTINUOUS DISTURBANCES .................................................................................. 7
5.1.1 Radiated Radio-frequency Electromagnetic Fields (RS) ............................................................. 7
5.1.2 Electrostatic Discharges (ESD) .................................................................................................... 8
6. PHOTOGRAPHS OF THE TEST SET-UP ....................................................................... 9
7. LIST OF TABLES .................................................................................................... 13
8. LIST OF PHOTOGRAPHS ......................................................................................... 13





Produkte
Products

Prfbericht - Nr.:
Test Report No.:
Draft Report

Seite 4 von 13
Page 4 of 13


1. General Remarks
1.1 Complementary Materials
No attachments along with this test report.
2. Test Sites
2.1 Test Facilities
1. TV Rheinland (India) Pvt. Ltd.
Plot No. 108, West Wing,
Electronics City Phase 1,
Bangalore 560 100
Website: www.ind.tuv.com

This test site is in accordance with CISPR 16 for measurement of radio interference.

The used test equipment is in accordance with CISPR 16 for measurement of radio
interference. The tests have been conducted by a TV Rheinland testing engineer.
2.2 List of Test and Measurement Instruments
Table 1: List of Test and Measurement Equipment

Kind of equipment Manufacturer Model S/N
Calibrated
until
Lab: TUV Rheinland (India) Pvt, Ltd
For Electro Static Discharge (ESD)
ESD Simulator Noiseken ESS 2002 EX ESS0999547 26-Jul-2014
For Radiated Susceptibility (RS)
Signal Generator Agilent E8257D-ATO-1895 MY51110514 04-Feb-2015
RF Power Amplifier MILMEGA 80RF1000-500 1045085 NA
RF Power Amplifier MILMEGA
AS0102-200 1045089
NA
RF Power Amplifier MILMEGA
AS1860-100 1045088
NA
Stacked Double
Logged Periodic
Antenna
Schwarz beck STLP9128D 9128D037 01-Nov-2014
Horn Antenna
Schwarz beck BBHA9120E BBHA9120E496 01-Nov-2014
Power Meter Agilent N1914A MY50001234 11-Feb-2015





Produkte
Products

Prfbericht - Nr.:
Test Report No.:
Draft Report

Seite 5 von 13
Page 5 of 13


3. General Product Information
3.1 Product Function and Intended Use
The EUT is a Smart HOT Watch that works with iPhone, Android and Windows
Phones. EUT connects to phones via Blue tooth and enables the user to dial and
answer calls directly from the watch. EUT will have a touch screen with a user-
friendly interface. The EUT can handle other tasks of phone apart from making and
receiving calls. EUT also has gesture support for accepting or rejecting a call.
3.2 Ratings and System Details
Supply Voltage: 5VDC (from USB)
Supply Current: 67mA

Battery Voltage: 4.2V 3.4V
Battery Current: 0.3mA 20mA

Protection Class: III

3.3 Independent Operation Modes
The basic operation modes are:

A. EUT Paired with phone for voice communication.
B. EUT Paired with phone for playing music.
3.4 Noise Generating and Noise Suppressing Parts
Noise Generating and suppressing parts are all parts of design.
3.5 Submitted Documents
None





Produkte
Products

Prfbericht - Nr.:
Test Report No.:
Draft Report

Seite 6 von 13
Page 6 of 13


4. Test Set-up and Operation Modes
4.1 Principle of Configuration Selection
Immunity: The equipment under test (EUT) was configured to have its highest
possible susceptibility against the tested phenomena. The test modes were adapted
accordingly in reference to the instructions for use.
4.2 Physical Configuration for Testing

Refer setup photograph for more details.
4.3 Test Operation and Test Software
During testing EUT was configured in the modes referred in clause 3.3 of this test report.
During which Bluetooth communication was monitored continuously.
4.4 Special Accessories and Auxiliary Equipment
Kind of equipment Manufacturer Model
Mobile phone Samsung S3
4.5 Countermeasures to achieve EMC Compliance
No additional measures were employed to achieve compliance.






Produkte
Products

Prfbericht - Nr.:
Test Report No.:
Draft Report

Seite 7 von 13
Page 7 of 13


5. Test Results I MMUNI TY
5.1 Continuous Disturbances
5.1.1 Radiated Radio-frequency Electromagnetic Fields (RS)
RESULT: PASS
Date of testing: 09-Apr-2014

Ambient temperature: 22.0C
Relative humidity: 51%
Atmospheric pressure: 91kPa

Reference standard: EN 301 489-1 V1.9.2:2011
EN 301 489-17 V2.2.1:2012
Test procedure: EN 61000-4-3:2006+A2:2010

Frequency range: (80 - 1000)MHz
Test level: 2 (3V/m) (unmodulated, rms.)

Frequency range: (1.4 - 2.7)GHz
Test level: 2 (3V/m) (unmodulated, rms.)
Modulation: 80% AM, 1kHz
Sweep rate: 1%, 2.85s dwell time

Test Mode: B

Supply voltage During Test: Battery Mode


Performance criterion: As per Clause 6 of EN 301489-1
Table 2: Immunity against Radiated Radio-frequency Electromagnetic Fields (RS)
Field Polarization Frequency Range Result Remark
Horizontal 80 1000MHz
1.4 2.7 GHz
Pass Communication was maintained
throughout the testing.
Vertical 80 1000MHz
1.4 2.7 GHz
Pass Communication was maintained
throughout the testing.





Produkte
Products

Prfbericht - Nr.:
Test Report No.:
Draft Report

Seite 8 von 13
Page 8 of 13


5.1.2 Electrostatic Discharges (ESD)
RESULT: PASS
Date of testing: 09-Apr-2014

Ambient temperature: 21.0C
Relative humidity: 52%
Atmospheric pressure: 91kPa

Reference standard: EN 301 489-1 V1.9.2:2011
EN 301 489-17 V2.2.1:2012
Test procedure: EN 61000-4-2:2009

Severity level: 2 (4kV) (contact discharge)
3 (8kV) (air discharge)
Number of discharges: >10

Test Mode: A

Supply voltage During Test: Battery Mode

Performance criterion: As per Clause 6 of EN 301489-1
Table 3: Electrostatic Discharges (ESD), both Polarities
Discharge Points Type of Discharge Result Remark
Top Enclosure:
Contact Pass Communication was maintained
throughout the testing.
Air Pass
Left Enclosure:
VCP & HCP Pass Communication was maintained
throughout the testing.
Right Enclosure:
VCP & HCP Pass Communication was maintained
throughout the testing.
Rear Enclosure:
AIR Pass Communication was maintained
throughout the testing.
Display:
AIR Pass Communication was maintained
throughout the testing.

VCP = Vertical Coupling Plane
HCP = Horizontal Coupling Plane




Produkte
Products

Prfbericht - Nr.:
Test Report No.:
Draft Report

Seite 9 von 13
Page 9 of 13


6. Photographs of the Test Set-Up
Photograph 1: Set-up for Radiated Susceptibility (RS), Vertical Antenna Orientation







Produkte
Products

Prfbericht - Nr.:
Test Report No.:
Draft Report

Seite 10 von 13
Page 10 of 13


Photograph 2: Set-up for Radiated Susceptibility (RS), Horizontal Antenna Orientation







Produkte
Products

Prfbericht - Nr.:
Test Report No.:
Draft Report

Seite 11 von 13
Page 11 of 13


Photograph 3: Set-up for Electrostatic Discharges (ESD), VCP & HCP







Produkte
Products

Prfbericht - Nr.:
Test Report No.:
Draft Report

Seite 12 von 13
Page 12 of 13


Photograph 4: Set-up for Electrostatic Discharges, Contact

Photograph 5: Set-up for Electrostatic Discharges, Air





Produkte
Products

Prfbericht - Nr.:
Test Report No.:
Draft Report

Seite 13 von 13
Page 13 of 13


7. List of Tables
Table 1: List of Test and Measurement Equipment ...................................................................................... 4
Table 2: Immunity against Radiated Radio-frequency Electromagnetic Fields (RS) .................................... 7
Table 3: Electrostatic Discharges (ESD), both Polarities .............................................................................. 8

8. List of Photographs
Photograph 1: Set-up for Radiated Susceptibility (RS), Vertical Antenna Orientation .................................. 9
Photograph 2: Set-up for Radiated Susceptibility (RS), Horizontal Antenna Orientation ........................... 10
Photograph 3: Set-up for Electrostatic Discharges (ESD), VCP & HCP ..................................................... 11
Photograph 4: Set-up for Electrostatic Discharges, Contact ....................................................................... 12
Photograph 5: Set-up for Electrostatic Discharges, Air ............................................................................... 12