Ams-B Eu
Ams-B Eu
Standby regulator
Residual pressure
Switch pressure between
operation and standby relief valve
Secondary air supply or exhaust
(shut-off) switching
Wireless adapter
(Accessories p. 47 )
Air consumption: p. 1
Max. 62 %∗1 reduction
∗1 In SMC conditions:
Maximum reduction ratio within product specifications
(at 0.7 MPa operating pressure and 0.2 MPa low pressure)
Compatible with p. 2
AMS20/30/40/60 Series
CAT.EUS100-155B-UK
Air Manageme
ent System AMS20
0/3
30/40/60 Serie
ie
es
Why not reduce the wasted air generated by your factory equipment?
Blow and purge in equipment standby Leakage from piping connections Leakage from cylinder
due to poor piping installation due to worn seals
Monitoring machine
condition
Flow rate
1800 l/min
Pressure
0.5 MPa
Pressure
0.5 MPa
Provides minimum required Air on the secondary side is consumed.∗1 Air consumption
pressure during standby to reduced by 50 % or more
reduce air consumption
Flow rate
100 l/min
0.5 MPa
0.2 MPa
Pressure ∗1 Varies depending on
Switched to standby pressure 0.2 MPa secondary side air
consumption
1
Air Ma
anagement Sy
ystem AMS 20/30/40/60
0 Series
Visualisation of production
equipment status
Flow, pressure, temperature, and other sensor
Equipment status can be
information can be communicated to the host monitored from another location
system via Industrial Ethernet or the OPC UA or from outside the office.
data communication
Host system
protocol.
Solenoid valve
Various switches
(Commercially available)
Temperature 24.9
[°C]
IO-Link port
2
Air Manageme
ent System AMS20
0/3
30/40/60 Serie
ie
es
Remote Remote
Remote
Remote
00 0 01
11 1 01
01 1
01 01
001 10
0 00 100
101
01
00
11
101
011 10
01 Base 011
000
011
11 1 0 111
010
10
101 00
001 01 100
00 001
110 1
100 010
101 011
Remote 01 1 10 0 1 1 0
10 0 1 0 1 1 0
00 011
1 1 00
11
010 101
Communication 001 01 11 001
101 10 110
00
cables1not
0 011 1 01 100
0 01 101
11
110
0 1required 11 010
000 01 10
011 0 0
00 00 00
001
11
001
1
01
01
11 11
10
0 1
1 0 01 Commu
Communication
01
Compact
11
distance: Max.
distan
10 wireless remote
01
1
0 0 10 100 m 1 1
10
Remote
1 0 10
10
0 00 01
00
11
01 01 1 01
10 Remote 11 01
1 10 01 Remote 0
1 10
10 00 Compact
00
11 11 wireless remote
10
0 10
10
10
11
01
0
+
Unauthorized Removing
wiretapping device
Remote
Unauthorized access//
data falsification
3
Air Ma
anagement Sy
ystem AMS 20/30/40/60
0 Series
System Configuration
Port size Flow capacity [l/min]
Communication
Series Size Output data
protocol
1/8 1/4 3/8 1/2 3/4 1 5 10 20 40 500 1000 2000 4000
Electro-Pneumatic
Regulator Type 20
AMS20A/30A/40A/60A
Series
30
40
· Instantaneous flow
· Accumulated flow
60 PROFINET · Pressure
EtherNet/IP™ · Fluid temperature
EtherCAT · Various sensor
Regulator Type information
20 OPC UA
AMS20B/30B/40B/60B transmitted via
Series IO-Link
· Diagnosis
30
40
60
Components
Residual pressure
relief valve connection
Standby input signal Standby regulator connection
Wireless adapter Isolation input signal Wireless
IO-Link master port adapter
Trademark
EtherNet/IP® is a registered trademark of ODVA, Inc.
EtherCAT® is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany.
4
Air Manageme
ent System AMS20
0/3
30/40/60 Serie
ie
es
Components
Standby Regulator
Based on the signal from the air management hub, the operating mode
shifts to standby mode and regulates the pressure to the standby pressure.
The non-relief type allows efficient use of air by not exhausting secondary-
side air during the standby mode transition.
¡Remote pressure setting and switching ¡Manual pressure setting and switching
during equipment startup/shutdown during equipment shutdown
(Equipment operating pressure is not
¡Select from normally closed or changed.)
normally open.
¡Normally open specification
¡With backflow function
¡With backflow function
¡With pressure ramp up duration setting
function
¡Block the air supply to the secondary ¡Block the air supply to the secondary side.
side.
¡Slow air ramp-up when equipment is
¡Select from normally closed or restarted
normally open.
¡Select from normally closed or
normally open.
5
Air Ma
anagement Sy
ystem AMS 20/30/40/60
0 Series
CONTENTS
Standby Regulator
AR20S to 50S Series
How to Order ……………………………………………………………………………………………… p. 28
Specifications ……………………………………………………………………………………………… p. 28
Dimensions ………………………………………………………………………………………………… p. 29
6
Air Management System
Electro-Pneumatic Regulator Type
Symbol
AMS20A/30A/40A/60A Series
N.C. N.O.
P #
P #
T #
T #
F #
F # 1 2
1 2
How to Order
AMS 40 A F 04 C PN M L G
q w e r t y u
앬
q
Symbol Description Body size
20 30 40 60
R Rc 앬 앬 앬 앬
N NPT 앬 앬 앬 앬
앬
w Pipe thread type
F G 앬 앬 앬 앬
H Without attachments 앬 앬 앬 앬
+
01 1/8 앬 — — —
02 1/4 앬 앬 — —
03 3/8 — 앬 앬 —
앬
e Port size 04 1/2 — — 앬 —
06 3/4 — — — 앬
10 1 — — — 앬
00 Without attachments 앬 앬 앬 앬
+
Electro-Pneumatic regulator, Residual C N.C. (Normally closed) 앬 앬 앬 앬
앬
r pressure relief 3-port solenoid valve
N.O./N.C.
D N.O. (Normally open) 앬 앬 앬 앬
+
SA Standalone (When wireless adapter is connected∗2: Wireless remote) 앬 앬 앬 앬
PN PROFINET, OPC UA (When wireless adapter is connected∗2: Wireless base) 앬 앬 앬 앬
앬
t Air management hub Protocol
EN EtherNet/IPTM, OPC UA (When wireless adapter is connected∗2: Wireless base) 앬 앬 앬 앬
EC EtherCAT∗3 (When wireless adapter is connected∗2: Wireless base) 앬 앬 앬 앬
+
Electro-Pneumatic regulator, K EXA1/ITV: Units selection function 앬 앬 앬 앬
앬
y Air management hub
Unit
M∗1 EXA1/ITV: SI units only 앬 앬 앬 앬
+
Residual pressure relief Manual G Non-locking push type 앬 앬 앬 앬
앬
u 3-port solenoid valve override E Push-turn locking type (Manual) 앬 앬 앬 앬
∗1 Fixed units Instantaneous flow : l/min
Accumulated flow : L
Pressure : kPa, MPa
Temperature : °C
∗2 The wireless adapter is sold separately. (Refer to page 48.)
∗3 EtherCAT is not compatible with OPC UA. In addition, the PLC (Programmable Logic Controller)/controller must support EoE (Ethernet over EtherCAT).
∗ The connection cable for the standby electro-pneumatic regulator/residual pressure relief valve is connected.
7
Air Management System
Electro-Pneumatic Regulator Type AMS20A/30A/40A/60A Series
8
AMS20A/30A/40A/60A Series
0.8 0.8
0.7 0.7
0.6 0.6
Set pressure [MPa]
0.4 0.4
0.3 0.3
0.2 0.2
0.1 0.1
0 0
0 50 100 150 200 250 300 350 400 450 500 0 50 100 150 200 250 300 350 400 450 500
0.8 0.8
0.7 0.7
0.6 0.6
Set pressure [MPa]
0.5 0.5
0.4 0.4
0.3 0.3
0.2 0.2
0.1 0.1
0 0
0 50 100 150 200 250 300 350 400 450 500 0 50 100 150 200 250 300 350 400 450 500
0.8 0.8
0.7 0.7
0.6 0.6
Set pressure [MPa]
0.5 0.5
0.4 0.4
0.3 0.3
0.2 0.2
0.1 0.1
0 0
0 50 100 150 200 250 300 350 400 450 500 0 50 100 150 200 250 300 350 400 450 500
Flow rate [l/min] (STD) Flow rate [l/min] (STD)
9
Air Management System
Electro-Pneumatic Regulator Type AMS20A/30A/40A/60A Series
0.8 0.8
0.7 0.7
0.6 0.6
Set pressure [MPa]
0.4 0.4
0.3 0.3
0.2 0.2
0.1 0.1
0 0
0 100 200 300 400 500 600 700 800 900 1000 0 100 200 300 400 500 600 700 800 900 1000
0.8 0.8
0.7 0.7
0.6 0.6
Set pressure [MPa]
0.5 0.5
0.4 0.4
0.3 0.3
0.2 0.2
0.1 0.1
0 0
0 100 200 300 400 500 600 700 800 900 1000 0 100 200 300 400 500 600 700 800 900 1000
0.8 0.8
0.7 0.7
0.6 0.6
Set pressure [MPa]
0.5 0.5
0.4 0.4
0.3 0.3
0.2 0.2
0.1 0.1
0 0
0 100 200 300 400 500 600 700 800 900 1000 0 100 200 300 400 500 600 700 800 900 1000
Flow rate [l/min] (STD) Flow rate [l/min] (STD)
10
AMS20A/30A/40A/60A Series
0.8 0.8
0.7 0.7
0.6 0.6
Set pressure [MPa]
0.4 0.4
0.3 0.3
0.2 0.2
0.1 0.1
0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 0 200 400 600 800 1000 1200 1400 1600 1800 2000
0.8 0.8
0.7 0.7
0.6 0.6
Set pressure [MPa]
0.5 0.5
0.4 0.4
0.3 0.3
0.2 0.2
0.1 0.1
0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 0 200 400 600 800 1000 1200 1400 1600 1800 2000
0.8 0.8
0.7 0.7
0.6 0.6
Set pressure [MPa]
0.5 0.5
0.4 0.4
0.3 0.3
0.2 0.2
0.1 0.1
0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 0 200 400 600 800 1000 1200 1400 1600 1800 2000
11
Air Management System
Electro-Pneumatic Regulator Type AMS20A/30A/40A/60A Series
0.8 0.8
0.7 0.7
0.6 0.6
Set pressure [MPa]
0.4 0.4
0.3 0.3
0.2 0.2
0.1 0.1
0 0
0 400 800 1200 1600 2000 2400 2800 3200 3600 4000 0 400 800 1200 1600 2000 2400 2800 3200 3600 4000
0.8 0.8
0.7 0.7
0.6 0.6
Set pressure [MPa]
0.5 0.5
0.4 0.4
0.3 0.3
0.2 0.2
0.1 0.1
0 0
0 400 800 1200 1600 2000 2400 2800 3200 3600 4000 0 400 800 1200 1600 2000 2400 2800 3200 3600 4000
0.8 0.8
0.7 0.7
0.6 0.6
Set pressure [MPa]
0.5 0.5
0.4 0.4
0.3 0.3
0.2 0.2
0.1 0.1
0 0
0 400 800 1200 1600 2000 2400 2800 3200 3600 4000 0 400 800 1200 1600 2000 2400 2800 3200 3600 4000
12
Air Management System
Regulator Type
Symbol
AMS20B/30B/40B/60B Series
N.C. N.O.
# P #
P
T #
T #
F #
F #
1 2
1 2
How to Order
AMS 40 B F 04 C PN M L G
q w e r t y u
앬
q
Symbol Description Body size
20 30 40 60
R Rc 앬 앬 앬 앬
앬
w Pipe thread type∗1 N NPT 앬 앬 앬 앬
F G 앬 앬 앬 앬
+
01 1/8 앬 — — —
02 1/4 앬 앬 — —
03 3/8 — 앬 앬 —
앬
e Port size 04 1/2 — — 앬 —
06 3/4 — — — 앬
10 1 — — — 앬
00 Without attachments 앬 앬 앬 앬
+
Regulator, Residual pressure relief C N.C. (Normally closed) 앬 앬 앬 앬
앬
r 3-port solenoid valve
N.O./N.C.
D N.O. (Normally open) 앬 앬 앬 앬
+
SA Standalone (When wireless adapter is connected∗3: Wireless remote) 앬 앬 앬 앬
PN PROFINET, OPC UA (When wireless adapter is connected∗3: Wireless base) 앬 앬 앬 앬
앬
t Air management hub Protocol
EN EtherNet/IPTM, OPC UA (When wireless adapter is connected∗3: Wireless base) 앬 앬 앬 앬
EC EtherCAT∗4 (When wireless adapter is connected∗3 : Wireless base) 앬 앬 앬 앬
+
Regulator, K Pressure gauge: MPa/psi dual scale, EXA1: Units selection function 앬 앬 앬 앬
앬
y Air management hub
Unit
M Pressure gauge in SI units: MPa, EXA1: SI units only∗2 앬 앬 앬 앬
+
Regulator/Residual pressure relief Manual G Non-locking push type 앬 앬 앬 앬
앬
u 3-port solenoid valve override E Push-turn locking type (Manual) 앬 앬 앬 앬
∗1 For port size "00", specify thread type of the standby regulator (ARS).
∗2 Fixed units Instantaneous flow : l/min
Accumulated flow : L
Pressure : kPa, MPa
Temperature : °C
∗3 The wireless adapter is sold separately. (Refer to page 48.)
∗4 EtherCAT is not compatible with OPC UA. In addition, the PLC (Programmable Logic Controller)/controller must support EoE (Ethernet over EtherCAT).
∗ The connection cable for the standby electro-pneumatic regulator/residual pressure relief valve is connected.
13
Air Management System
Regulator Type AMS20B/30B/40B/60B Series
∗1 Refer to the table below for the single unit specifications of the components.
· Standby regulator p. 28
· Air management hub p. 21
· Residual pressure relief 3-port solenoid valve p. 30
14
AMS20B/30B/40B/60B Series
0.8 0.8
0.7 0.7
0.6 0.6
Outlet pressure [MPa]
0.4 0.4
0.3 0.3
0.2 0.2
0.1 0.1
0 0
0 100 200 300 400 500 0 100 200 300 400 500 600 700 800 900 1000
0.8 0.8
0.7 0.7
0.6 0.6
Outlet pressure [MPa]
0.5 0.5
0.4 0.4
0.3 0.3
0.2 0.2
0.1 0.1
0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 0 400 800 1200 1600 2000 2400 2800 3200 3600 4000
15
Air Management System
Regulator Type AMS20B/30B/40B/60B Series
0.25 0.25
0.20 0.20
Outlet pressure [MPa]
0.10 0.10
0.05 0.05
0.00 0.00
0 100 200 300 400 500 0 100 200 300 400 500 600 700 800 900 1000
0.25 0.25
0.20 0.20
Outlet pressure [MPa]
0.15 0.15
0.10 0.10
0.05 0.05
0.00 0.00
0 200 400 600 800 1000 1200 1400 1600 1800 2000 0 1000 2000 3000 4000
16
AMS20/30/40/60 Series
R
M
C
W
Q Q
V
T
2xP
(Port size)
D
U
B
L
AMS20/30/40/60A-H00C
SA: Standalone Back side
(Without attachments)
(Wireless remote)
A
F
Bracket dimensions
Model P A B C D E J M L
K F G H Q R S T U V W
AMS20A-첸C 1/8, 1/4 274.3 214.7 81.7 134.4 25.6 46.2 24 40.1 85 70.2 103.2 49.7 35 7 14 54.5 6 47 42.5
AMS30A-첸C 1/4, 3/8 291.8 214.7 87.9 134.4 29.1 46.2 30 40.1 85 72.2 104.2 57.2 35 7 14 54.5 6 47 42.5
AMS40A-첸C 3/8, 1/2 334.8 214.9 92.4 151.6 32.6 46.2 36 40.1 85 89.2 105.2 75.2 40 9 18 65 7 55 50
AMS60A-첸C 3/4, 1 401.8 214.8 93.7 151.6 42.1 46.2 46 40.1 100 90.2 126.2 101.2 50 11 20 80 8 70 60
Model P A F
AMS20A-H00C — 219.9 68.6
AMS30A-H00C — 229.4 70.1
AMS40A-H00C — 264.4 86.6
AMS60A-H00C — 311.4 87.1
17
Air Management System AMS20/30/40/60 Series
R
M
W
Q Q
V
T
2xP
C
(Port size)
D
U
B
L
AMS20/30/40/60A-H00D
(Without attachments) SA: Standalone Back side
(Wireless remote)
A
F
Bracket dimensions
Model P A B C D E J M L
K F G H Q R S T U V W
AMS20A-첸D 1/8, 1/4 274.3 214.7 85.1 134.4 25.6 46.2 24 40.1 85 70.2 103.2 49.7 35 7 14 54.5 6 47 42.5
AMS30A-첸D 1/4, 3/8 291.8 214.7 102.1 134.4 29.1 46.2 30 40.1 85 72.2 104.2 57.2 35 7 14 54.5 6 47 42.5
AMS40A-첸D 3/8, 1/2 334.8 214.9 119.4 151.6 32.6 46.2 36 40.1 85 89.2 105.2 75.2 40 9 18 65 7 55 50
AMS60A-첸D 3/4, 1 401.8 214.8 117.7 151.6 42.1 46.2 46 40.1 100 90.2 126.2 101.2 50 11 20 80 8 70 60
Model P A F
AMS20A-H00D — 219.9 68.6
AMS30A-H00D — 229.4 70.1
AMS40A-H00D — 264.4 86.6
AMS60A-H00D — 311.4 87.1
18
AMS20/30/40/60 Series
R
M
C
D
W
Q Q
V
T
2xP
(Port size)
U
B
L
Bracket dimensions
Model P A B C D∗1 E J M L
K F G H Q R S T U V W
AMS20B-첸C 1/8, 1/4 301.8 214.7 81.7 66.8 25.6 46.2 24 40.1 85 71.2 103.2 76.2 35 7 14 54.5 6 47 42.5
AMS30B-첸C 1/4, 3/8 348.3 214.7 87.9 86.5 29.1 46.2 30 40.1 85 85.2 104.2 100.7 35 7 14 54.5 6 47 42.5
AMS40B-첸C 3/8, 1/2 395.8 214.9 92.4 91.5 32.6 46.2 36 40.1 85 103.2 105.2 122.2 40 9 18 65 7 55 50
AMS60B-첸C 3/4, 1 491.8 214.8 93.4 125 42.1 46.2 46 40.1 100 124.2 126.2 157.2 50 11 20 80 8 70 60
Model P A F
AMS20B-첸00C — 247.4 69.6
AMS30B-첸00C — 285.9 83.1
AMS40B-첸00C — 325.4 100.6
AMS60B-첸00C — 401.4 121.1
∗1 The dimension of D is the length when the regulator knob is unlocked.
19
Air Management System AMS20/30/40/60 Series
R
M
D
W
Q Q
V
T
2xP
C
(Port size) U
B
L
Bracket dimensions
Model P A B C D∗1 E J M L
K F G H Q R S T U V W
AMS20B-첸D 1/8, 1/4 301.8 214.7 85.1 66.8 25.6 46.2 24 40.1 85 71.2 103.2 76.2 35 7 14 54.5 6 47 42.5
AMS30B-첸D 1/4, 3/8 348.3 214.7 102.1 86.5 29.1 46.2 30 40.1 85 85.2 104.2 100.7 35 7 14 54.5 6 47 42.5
AMS40B-첸D 3/8, 1/2 395.8 214.9 119.4 91.5 32.6 46.2 36 40.1 85 103.2 105.2 122.2 40 9 18 65 7 55 50
AMS60B-첸D 3/4, 1 491.8 214.8 118 125 42.1 46.2 46 40.1 100 124.2 126.2 157.2 50 11 20 80 8 70 60
Model P A F
AMS20B-첸00D — 247.4 69.6
AMS30B-첸00D — 285.9 83.1
AMS40B-첸00D — 325.4 100.6
AMS60B-첸00D — 401.4 121.1
∗1 The dimension of D is the length when the regulator knob is unlocked.
20
Air Management Hub
Symbol
EXA1 Series
P #
T #
F #
How to Order
EXA1 40 SA M L
q w e
앬
q
Symbol Description Body size
20 30 40 60
SA Standalone (When wireless adapter is connected∗2: Wireless remote) 앬 앬 앬 앬
PN PROFINET, OPC UA (When wireless adapter is connected∗2: Wireless base) 앬 앬 앬 앬
앬
w Protocol
EN EtherNet/IPTM, OPC UA (When wireless adapter is connected∗2: Wireless base) 앬 앬 앬 앬
EC EtherCAT∗3 (When wireless adapter is connected∗2 : Wireless base) 앬 앬 앬 앬
+
K Units selection function 앬 앬 앬 앬
앬
e Unit
M∗1 SI units only 앬 앬 앬 앬
∗1 Fixed units Instantaneous flow: l/min, Accumulated flow: L, Pressure: kPa/MPa, Temperature: °C
∗2 The wireless adapter is sold separately. (Refer to page 48.)
∗3 EtherCAT is not compatible with OPC UA. In addition, the PLC (Programmable Logic Controller)/controller must support EoE (Ethernet over EtherCAT).
21
Air Management Hub EXA1 Series
2
Fluid temperature 0 to 50 °C communication ports
Power supply voltage 24 VDC ±10 % PROFINET IO
Electrical
Protocol
Communication
Protection Polarity protection, Over current protection (Conformance Class C)
Current consumption 400 mA Communication speed 100 Mbps
Indicator LED & LCD Configuration file GSDML file∗3
Operating temperature range 0 to 50 °C (No freezing and condensation) Occupation area
Max.
Storage temperature range −10 to 60 °C (No freezing and condensation) (Number of
(406 byte/198 byte)
Environment
Input/
Max. process Output Fail safe HOLD/CLEAR
Input: 16 bytes/Output: 16 bytes (per port) Output
data size
∗4 The configuration file can be downloaded from
IO-Link version Version 1.1
the SMC website.
IO-Link port class Class A https://www.smc.eu
Input type PNP input
Protocol specifications (EXA1-첸-EC)
Input/Output
inputs/outputs)
Pin 2: Typ. 2.5 mA, Supported (When using EoE)∗6
Rated input current Web server
Input for standby Pin 4: Typ. 5.8 mA
OPC UA Not supported
Input for isolation ON voltage 13 V or more
Input/
OFF voltage 8 V or less Output Fail safe HOLD/CLEAR
Output
Max. supply current 0.3 A
∗5 The configuration file can be downloaded from
Weight 750 g 770 g 810 g 1140 g
the SMC website.
∗1 Air quality grade is JIS B 8392-1:2012 [4:6:-] and ISO 8573-1:2010 [4:6:-]. https://www.smc.eu
∗2 When the flow range is less than 10%, temperature accuracy is -2.5 to 7.5 °C. ∗6 The PLC (Programmable Logic Controller)/controller
must support EoE (Ethernet over EtherCAT).
22
EXA1 Series
B
A
40.1
D
80.2
C
Model A B C D E F
EXA1-20 236.2 35 42 19.1 65.1 30.5
EXA1-30 236.2 43 53 13.6 65.1 30.5
EXA1-40 240.4 51 71 4.6 71 35.5
EXA1-20/30/40-SA-첸
1.5 E
F 100
B
A
40.1
D
G
C
Model A B C D E F G
EXA1-20 236.2 35 42 19.1 65.1 30.5 74.7
EXA1-30 236.2 43 53 13.6 65.1 30.5 74.7
EXA1-40 240.4 51 71 4.6 71 35.5 75.6
23
Air Management Hub EXA1 Series
Dimensions: Size 60
EXA1-60-PN/EN-첸 1.5 90
45 120
64
246.8
40.1
90
EXA1-60-SA-첸 1.5 90
45 120
64
246.8
40.1
90
1.5
24
Standby Electro-Pneumatic Regulator
Symbol
ITV2050 to 3050-X399
N.C./N.O.
How to Order
Specifications
50
D
1.7
4.65 10.4
(33)
(8.5) 23.2
22.2
SUP OUT
Solenoid valve EXH
M5 x 0.8
Solenoid
145.6
(12.4)
11
Model A B C D E F G
ITV2050-20-첸-X399 50 2.4 11.8 64.5 8.5 67 12.5
ITV2050-30-첸-X399 53 0.9 10.5 64.4 9 68 13.5
26
ITV2050 to 3050-X399
84
N.O. (Normally open) 50
50
B
10
(33)
15.35 10.4
(8.5) 23.2 13.45 14.2 9 13.65
SUP OUT
M5 x 0.8
45.8
Solenoid
Solenoid valve EXH
valve EXH
D
8.5 M12 x 1 10 10
C 37 Power cable Waterproof cover∗1
connection thread ∗ 1 If it is a normally closed
(Plug type) specification, do not remove it as it
will not be used.
ITV3050-60
(1.5)
72.5
90
71
Model A B C D
ITV3050-40-첸-X399 26.5 72.5 35.5 166.8
ITV3050-60-첸-X399 33 90 45 173.6
27
Standby Regulator
Symbol
AR20S to 50S Series
How to Order
q w e r t
앬
q
Symbol Description Body size
20 30 40 50
— Rc 앬 앬 앬 앬
앬
w Pipe thread type N NPT 앬 앬 앬 앬
F G 앬 앬 앬 앬
+
02 1/4 앬 — — —
Port size 03 3/8 — 앬 — —
앬
e (Screws are IN side only.) 04 1/2 — — 앬 —
10 1 — — — 앬
+
Pressure — Name plate and pressure gauge in SI units: MPa 앬 앬 앬 앬
앬
r gauge
Unit
Z Name plate: MPa, Pressure gauge: MPa/psi dual scale 앬 앬 앬 앬
+
Manual — Non-locking push type 앬 앬 앬 앬
앬
t Pilot valve
override E Push-turn locking type (Manual) 앬 앬 앬 앬
28
AR20S to 50S-D Series
Dimensions
A
H
E D
B
IN OUT
F
J
첸28
P1
IN port
G
M
C
X
K
Light/surge voltage suppressor
27.3 10.9
M12 x 1
Power cable connection thread
E: Push-turn locking type (Plug type)
N
4(+) 3(−)
5(Grounding)
1/4
Pressure outlet port
Model P1 A B∗1 C D E F G H J K M N
AR20S 1/4 68 66.8 73 26 27 17.5 26.5 20 2 54 56.7 55.6
AR30S 3/8 81 86.5 79 31.5 32.5 21.5 30.5 26.5 3.5 67 62.7 69.1
AR40S 1/2 98 91.5 83 40.5 41.5 25.5 35.5 35 — 84 66.7 86.6
AR50S 1 118 125 90.5 50 51 32 43 45 — 104 74.2 105
∗1 The dimension of B is the length when the regulator knob is unlocked.
29
Residual Pressure Relief 3-Port Solenoid Valve
Symbol
VP346E/546E/746E/946E-X660/X661
With soft start-up function
N.C. N.O. N.C. N.O.
How to Order
q w e r t
q Series w M12 connector
Pin Series
assignment VP300 VP500 VP700 VP900
3 VP300
5 VP500
Without
7 VP700 KO — — — 앬
connector
9 VP900
Without
KVO 앬 앬 앬 —
connector
∗ This valve is a large flow rate pilot-operated solenoid valve. If the operating pressure falls below
0 . 2 MPa due to a pressure drop caused by insufficient air supply, it may not be able to switch
properly.
30
VP346E/546E/746E/946E-X660/X661
Dimensions
N.C. (Normally closed)
Light/surge voltage suppressor
VP346E-X660 Detailed figure of a section
M12 connector
a
3(ä) 5(Grounding)
Vent port
4(+)
65.4
45.6
View A (42)
(21)
4.3
G1/4
[3(R) port]
EXH.
(50.9)
29.9
M12 x 1
Manual override
Locking type: Press,
81.7
View A
(124.2)
17.5
35
42.5
31
Residual Pressure Relief
3-Port Solenoid Valve VP346E/546E/746E/946E-X660/X661
Dimensions
N.O. (Normally open)
VP346E-X661
Detailed figure of b section
M12 connector
4(+)
19.8
5(Grounding) 3(ä)
68.8
G1/4
Vent port [3(R) port] Details of manual override part
EXH. (for manual operation)
Type E
45.6
b
View A
(42)
17.5
35
(109.6)
View A
85.1
Manual override
Locking type: Press,
then rotate it.
Manual override part
M12 x 1
29.9
32
VP346E/546E/746E/946E-X660/X661
Dimensions
With soft start-up function Light/surge voltage suppressor
N.C. (Normally closed)
a
VP346E-S-X660 Detailed figure of a section
M12 connector
3(ä) 5(Grounding)
Vent port
Vent port
65.4
4(+)
View A
(42)
(21)
4.3
G1/4
[3(R) port]
EXH.
(50.9)
29.9
M12 x 1
Manual override
Locking type: Press,
81.7
29.5
17.5
35
27.9
42.5
33
Residual Pressure Relief
3-Port Solenoid Valve VP346E/546E/746E/946E-X660/X661
Dimensions
With soft start-up function
Detailed figure of b section
N.O. (Normally open) M12 connector
VP346E-S-X661
4(+)
19.8
3(ä)
5(Grounding)
68.8
View A
(42)
17.5
35
27.9
(114.6)
85.1
M12 x 1
29.9
34
VP346E/546E/746E/946E-X660/X661
Dimensions
N.C. (Normally closed)
VP546E-X660
Light/surge voltage suppressor
55.4
Vent port
71.6
(53)
(26.5)
4(+)
G3/8
3(R) port
(55.9) EXH
29.4 M12 x 1
Manual override
Locking type: Press,
View A then rotate it.
87.9
(155.6)
21.5
43
67.7
26.5 26.5
26.5
53
35
Residual Pressure Relief
3-Port Solenoid Valve VP346E/546E/746E/946E-X660/X661
Dimensions
N.O. (Normally open)
VP546E-X661
23.2
Details of manual override part
85.8 (for manual operation)
G3/8
Vent port [3(R) port]
EXH.
b 55.4
Light/surge voltage suppressor
View A
4(+)
5(Grounding) 3(ä)
(55.5)
29
53
26.5 26.5
2(A) port 26.5
OUT 1(P) port
IN
32.5
21.5
43
(134.6)
102.1
View A
29.4 M12 x 1
Manual override
Locking type: Press,
then rotate it.
36
VP346E/546E/746E/946E-X660/X661
Dimensions
With soft start-up function
N.C. (Normally closed)
VP546E-S-X660 Light/surge voltage suppressor
Details of manual override part
a (for manual operation)
55.4
Vent port
Vent port
71.6
View A
Detailed figure of a section
M12 connector
5(Grounding)
6.5
3(ä)
(53)
(26.5)
4(+)
G3/8
3(R) port
(55.9) EXH
M12 x 1
29.4
Manual override part
Manual override
Locking type: Press,
View A
87.9
21.5
43
46.7
67.7
26.5 26.5 70
96.5
37
Residual Pressure Relief
3-Port Solenoid Valve VP346E/546E/746E/946E-X660/X661
Dimensions
With soft start-up function
N.O. (Normally open)
Vent port
VP546E-S-X661 Details of manual override part
(for manual operation)
23.2
85.8
55.4
b
Light/surge voltage suppressor
View A
Detailed figure of b section
M12 connector
4(+)
3(ä)
5(Grounding)
(55.5)
29 96.5
1(P) port
26.5 26.5 70
IN
2(A) port
OUT
37.5
32.5
21.5
43
46.7
(139.6)
102.1
View A
38
VP346E/546E/746E/946E-X660/X661
Dimensions
Light/surge voltage suppressor
N.C. (Normally closed)
VP746E-X660 a
Details of manual override part
Vent port (for manual operation)
73.4
76.1
View A
(71)
5(Grounding)
3(ä)
(35.5)
G3/8 4(+)
3(R) port
EXH
(55.9)
M12 x 1
20.4
Manual override part
Manual override
View A Locking type: Press,
then rotate it.
92.4
25.5
(183.4)
51
2(A) port
91
35.5 35.5 35
70
39
Residual Pressure Relief
3-Port Solenoid Valve VP346E/546E/746E/946E-X660/X661
Dimensions
N.O. (Normally open)
VP746E-X661
Details of manual override part
(for manual operation)
35.9
103.1
G1/4 73.4
Vent port
[3(R) port]
EXH.
b
Light/surge voltage suppressor
Detailed figure of b section
View A M12 connector
4(+)
5(Grounding) 3(ä)
25.5
51
(157.4)
119.4
View A
40
VP346E/546E/746E/946E-X660/X661
Dimensions
Light/surge voltage suppressor
With soft start-up function
N.C. (Normally closed) a
VP746E-S-X660 Details of manual override part
(for manual operation)
Vent port
73.4
Vent port
76.1
5(Grounding)
3(ä)
11.5
(71)
(35.5)
4(+)
G3/8
3(R) port
(55.9)
EXH
20.4 M12 x 1
Manual override part
View A
Manual override
Locking type: Press,
then rotate it.
92.4
2(A) port
OUT
44.1
25.5
(183.4)
51
65
1(P) port
91
IN
35.5 35.5 82
117
41
Residual Pressure Relief
3-Port Solenoid Valve VP346E/546E/746E/946E-X660/X661
Dimensions
With soft start-up function Vent port
N.O. (Normally open) Details of manual override part
(for manual operation)
VP746E-S-X661
35.9
103.1
73
G1/4
Vent port
[3(R) port]
EXH.
b
Light/surge voltage suppressor Detailed figure of b section
View A M12 connector
4(+)
5(Grounding) 3(-)
(71) 117
35.5 35.5 82 1(P) port
2(A) port IN
OUT
44.1
38
25.5
51
(163.5)
65
119.4
View A
42
VP346E/546E/746E/946E-X660/X661
Dimensions
N.C. (Normally closed)
VP946E-X660 a
Light/surge voltage suppressor
77.4
5(Grounding)
3(ä)
View A
(90)
22.3
(45)
G1
[3(R) port]
EXH.
11.1
M12 x 1
Manual override part
2(A) port 1(P) port
OUT Manual override IN
Locking type: Press,
then rotate it.
93.7
32
(184.2)
64
View A
90.5
45 45 47.5
95
43
Residual Pressure Relief
3-Port Solenoid Valve VP346E/546E/746E/946E-X660/X661
Dimensions
N.O. (Normally open) Detailed figure of b section
VP946E-X661 M12 connector
5(Grounding)
3(ä)
4(+)
101.4
Details of manual override part
(for manual operation)
Type E
View A
92.2
(90)
72
G3/4
[3(R) port]
EXH.
(138.5)
93.5 95
Vent port 45 45 47.5 Vent port
32
64
(165.2)
117.7
Manual override
Locking type: Press,
View A then rotate it.
44
VP346E/546E/746E/946E-X660/X661
Dimensions
With soft start-up function a Light/surge voltage suppressor
N.C. (Normally closed)
VP946E-S-X660
Vent port Detailed figure of a section
M12 connector
4(+)
77.4
5(Grounding) 3(ä)
View A
Vent port
(90)
22.3
(45)
G1
[3(R) port]
EXH.
11.1
M12 x 1
Manual override 1(P) port
Locking type: Press, IN
2(A) port then rotate it.
OUT
93.7
47.5
32
(184.2)
64
71.5
90.5
45
Residual Pressure Relief
3-Port Solenoid Valve VP346E/546E/746E/946E-X660/X661
Dimensions
With soft start-up function
N.O. (Normally open)
VP946E-S-X661
Detailed figure of b section
M12 connector
5(Grounding)
3(ä)
101.4
4(+)
View A
92.2
(90)
(45)
72
Vent port
G3/4
(138.5) [3(R) port]
EXH.
93.5 151
45 45 103.5
1(P) port
2(A) port IN
OUT
47.5
32
64
(165.2)
71.5
117.7
Vent port
Manual override part
View A
11.1 M12 x 1
Manual override
Locking type: Press,
then rotate it.
46
AMS20/30/40/60 Series
Accessories
List of Accessories
!0 Communication Cable
p. 52
w Seal Cap (M12)
∗ 1 pc. (0 pcs. for the AMS첸-SA)
p. 48
o Marker
p. 52 q Wireless Adapter
p. 48
p. 49
47
Accessories AMS20/30/40/60 Series
q Wireless Adapter
Wireless adapter for air management hub EXA1
EXW1-A11N
Specifications Radio Law-compliance label
Item Specifications
Protocol SMC original protocol (SMC encryption) 89.8
Radio wave type (spread) Frequency Hopping Spread Spectrum (FHSS) 77.3 19.4
Frequency 2.4 GHz (2403 to 2481 MHz)
Number of frequency channels 79 ch
18.5
Channel bandwidth 1.0 MHz
Wireless
12
Communication speed 1 Mbps
communication
Approx. 100 m
Communication distance Model label
(Depending on the operating environment)
Refer to the SMC website for the
Radio Law certificate latest information regarding in which
countries the product is certified.
Power supply voltage range 24 VDC +10 % to 12 VDC −10 %
Electrical
Current consumption 50 mA or less
Enclosure IP67
Ambient temperature
0 to 50 °C
(Operating temperature) Connector
Ambient temperature M8, 4-pin, plug Terminal no. Description
−10 to 60 °C
(Storage temperature) 1 24V (US1)
Ambient humidity 35 to 85 %RH (No condensation) 3 1
2 Internal bus B
Withstand voltage 500 VAC, 1 min
3 0V (US1)
General Insulation resistance 500 VDC, 10 MΩ or more 4 2
4 Internal bus A
Conforms to EN 61131-2
Vibration resistance 5 < = f < 8.4 Hz 3.5 mm
8.4 < = f < 150 Hz 9.8 m/s2
Conforms to EN 61131-2
Impact resistance
147 m/s2, 11 ms
Standards CE/UKCA marking
Wireless adapter
Weight 40 g
∗ Included parts: Fixing bracket
Please purchase an EXW1-AC-X1 connection cable separately.
w Seal Cap (10 pcs.) e Power Supply Cable (M8 connector, For EXW1-A11N,
Be sure to mount a seal cap on any unused I/O With connectors on both sides (socket/plug))
connectors.
Otherwise, the specified enclosure cannot be EXW1-AC1-X1 Straight 0.3 m
maintained. ∗ This product must be used in a fixed position.
Ø 5.5
EX9-AWES EX9-AWTS
For M8 For M12
300
Socket connector Plug connector pin
pin arrangement Terminal Terminal arrangement
no. no.
4 2 1 1 2 4
3 3
3 1 1 3
2 2
4 4
Connections
Item Specifications
Cable O.D. Ø 5.5 mm
Conductor nominal cross section AWG24
Wire O.D. (Including insulator) 1.12 mm
Min. bending radius 22 mm
48
AMS20/30/40/60 Series
r Power Supply Cable (M12 connector, For EXA1) ∗ The shape of the M12 connector is A-coded (Normal key).
EX500-AP 050 - S
Cable length (L) Connector specification
010 1000 mm S Straight
050 5000 mm A Angled
M12
1 2 M12
Ø6
5
Ø 14.9
4 3 27 30 5 1 2
Ø6
5
28.3
Socket connector 40.7 50
pin arrangement L
4 3
A-coded 25.3 30 5
(Normal key) Socket connector L 50
pin arrangement
A-coded
Item Specifications Item Specifications
(Normal key)
Cable O.D. Ø 6 mm Cable O.D. Ø 6 mm
Nominal cross section 0.3 mm2/AWG22 Nominal cross section 0.3 mm2/AWG22
Wire diameter (Including insulator) 1.5 mm Wire diameter (Including insulator) 1.5 mm
Min. bending radius 40 mm (Fixed) Min. bending radius 40 mm (Fixed)
Connections
ZS-37-A
Lead wire with M12 connector
38.5 3000 Cable Specifications
Pin no. Pin name Wire colour 1: Brown 2: White Item Specifications
45
1 DC(+) Brown Conductor Nominal cross section AWG23
Ø 15
1 2
2 N.C. White 4 3
t Connection Cable for Standby Regulator/Residual Pressure Relief Valve (With M12 angle connectors on both sides (male/female))
∗ Included with AMS첸A/B air management systems
EXA1-AC1 Cable length L: 320 mm
EXA1-AC2 Cable length L: 220 mm Ø 15
M12 4-pin male connector
(Right angle)
M12 5-pin female connector
No.3 (Right angle) No.3 No.2
34.5
No.2
Ø4
No.5
30.8
Terminal no. Terminal no. Component and Connection Cable Suitable Table
1 1
2 2
Body Standby electro- Standby Residual pressure
3 3 size pneumatic regulator regulator relief valve
4 4
5 5 20
Connections
30 EXA1-AC2
EXA1-AC1 EXA1-AC2
40
60 EXA1-AC1
49
Accessories AMS20/30/40/60 Series
y u
y Piping Adapter
A piping adapter allows for the installation/removal of the component
without removing the piping and thus makes maintenance easier.
E 200 - 01 -D
Applicable size Port size
200 AMS20 Thread type Symbol Port size AMS20 AMS30 AMS40
S40 AMS60
300 AMS30 Symbol Thread type 01 1/8 앬
400 AMS40 — Rc 02 1/4 앬 앬
600 AMS60 F G 03 3/8 앬 앬
N NPT 04 1/2 앬
06 3/4 앬
10 1 앬
D Model P A B C D
Width P (Port size)
across flats E200-첸01-D 1/8 24 35 42 24
E200-첸02-D 1/4 24 35 42 24
E300-첸02-D 1/4 27 43 53 30
E300-첸03-D 3/8 27 43 53 30
B
E400-첸03-D 3/8 30 51 71 36
Centre of E400-첸04-D 1/2 30 51 71 36
C F.R.L. body A E600-첸06-D 3/4 39 64 90 46
E600-첸10-D 1 39 64 90 46
∗ A spacer with bracket is required for modular unit.
B
E
EE
A
(Spacer width)
i Silencer
ØB
A
A
A
øB
51
Accessories AMS20/30/40/60 Series
EX600-ZT1
!0 Communication Cable
Ø 14.8
Cable length (L) 47.3 L 47.3
2 1 2 1
005 500 mm
010 1000 mm
020 2000 mm 3 4 3 4
Ø 6.5
Ø 6.5
020 Metal
2000 mm 3 1
parts Metal parts
030 3000 mm Plug connector
Plug connector M12
050 5000 mm pin arrangement M12 pin arrangement
SPEEDCON D-coded
100 10000 mm D-coded Ø 15 SPEEDCON
52
AMS20/30/40/60 Series
!0 Communication Cable
Ø 14.8
Cable length (L) Metal parts
Ø 6.4
M12 Metal parts RJ-45
010 1000 mm
020 2000 mm
030 3000 mm 47.3 L 44
050 5000 mm
Terminal Terminal Core wire
100 10000 mm
colour 1
2 1 no. no. 2
3
TD+ 1 1 White/Orange 4
5
RD+ 2 2 Orange 6
3 4 7
TDä 3 3 White/Green
8
4 4
RDä 5
Plug connector Metal parts 6 Green
Plug connector
pin arrangement 7 pin arrangement
D-coded 8
Item Specifications
Cable O.D. Ø 6.4 mm
Conductor nominal cross section 0.14 mm2/AWG26
Wire O.D. (Including insulator) 0.98 mm
Min. bending radius (Fixed) 26 mm
Ø 14.8
3 4
Connections
Item Specifications
Cable O.D. 6.5 mm
Conductor nominal cross section AWG22
Wire O.D. (Including insulator) 1.55 mm
Min. bending radius (Fixed) 45.5 mm
53
Accessories AMS20/30/40/60 Series
Ø 14.9
Ø 14.9
Cable length (L) 3 4 40.7 44.7 2 1
Ø6
005 500 mm 5 5
010 1000 mm
020 2000 mm 2 1 3 4
030 3000 mm Socket connector pin arrangement Plug connector pin arrangement
A-coded (Normal key) M12 M12 A-coded (Normal key)
050 5000 mm
100 10000 mm Terminal no. Wire guide colour
Item Specifications
1 1 Brown Cable O.D. Ø 6 mm
2 2 White
3 3 Blue Conductor nominal cross section 0.3 mm2/AWG22
4 4 Black Wire O.D. (Including conductor) 1.5 mm
5 5 Grey Min. bending radius (Fixed) 40 mm
Connections
32.3
Ø6
28.3
2 4 3 1
030 3000 mm
050 5000 mm
1 4
100 10000 mm
25.3 25.3
Socket connector pin arrangement Plug connector pin arrangement
A-coded (Normal key) L A-coded (Normal key)
∗ When using the Y connector, connect it to the connector on the I/O unit through the sensor cable (PCA-1557769) with the M12 connector.
54
AMS20/30/40/60 Series
Ø
11
(6)
55
AMS20/30/40/60 Series
Specific Product Precautions 1
Be sure to read this before handling the products. Refer to the back cover for safety
instructions. For common precautions, refer to the “Operation Manual” on the SMC
website: https://www.smc.eu
Warning Warning
1. Confirm the specifications. 1. To screw piping material into a component, tighten
Products represented in this catalog are designed only for use in with the recommended tightening torque while
compressed air systems. holding the female thread side.
Do not operate at flow rates, pressures, temperatures, etc., beyond If the tightening torque is insufficient, looseness or seal failure
the range of specifications, as this can cause damage or may occur. On the other hand, excess tightening torque can
malfunction. (Refer to the specifications.) cause damage to the threads. Furthermore, tightening without
Please contact SMC when using a fluid other than compressed air. holding the female thread side can cause damage due to the
We do not guarantee against any damage if the product is used excess force that is applied directly to the piping bracket.
outside of the specification range. Recommended Tightening Torque Unit: N·m
Connection thread 1/ 8 1/ 4 3/ 8 1/ 2 3/ 4 1
2. Do not disassemble the product or make any
modifications, including additional machining. Torque 3 to 5 8 to 12 15 to 20 20 to 25 28 to 30 36 to 38
Caution
1 . Do not use a lubricator on the supply side of this
product, as doing so may result in a malfunction.
When lubrication of terminal equipment is
necessary, connect a lubricator on the output side
of this equipment.
56
AMS20/30/40/60 Series
Specific Product Precautions 2
Be sure to read this before handling the products. Refer to the back cover for safety
instructions. For common precautions, refer to the “Operation Manual” on the SMC
website: https://www.smc.eu
Warning Warning
1. Type of fluids 6. If the product to be returned is contaminated or is
Please consult with SMC when using the product in possibly contaminated with substances that are
applications other than compressed air. harmful to humans, for safety reasons, please
contact SMC beforehand and then employ a
2. Take measures to ensure air quality, such as by
specialist cleaning company to decontaminate the
installing an aftercooler, air dryer, or water separator.
product. After the decontamination prescribed
Compressed air that contains a large amount of drainage can result above has been carried out, submit a Product
in the malfunction of this product and other pneumatic equipment. Return Request Sheet or the Detoxification/
Therefore, take appropriate measures to ensure air quality, such as Decontamination Certificate to SMC and await
by providing an aftercooler, air dryer, or water separator. SMC’s approval and further instructions before
For compressed air quality, refer to the Air Preparation attempting to return the item.
Equipment Selection Guide (Web Catalogue). Please refer to the International Chemical Safety
3. Use clean compressed air. Cards (ICSC) for a list of harmful substances.
Do not use compressed air that contains chemicals, synthetic If you have any further questions, please don’t
oils that include organic solvents, salt, corrosive gases, etc., as hesitate to contact your SMC sales representative.
it can cause damage or malfunction.
When synthetic oil is used for the compressor oil, depending on
the type of synthetic oil used or on the conditions of use, there Maintenance
may be adverse effects on the resin of the pneumatic equipment
or on the seals if the oil is flowed out to the outlet side. The
mounting of a main line filter is recommended in such cases.
Warning
1. Maintenance work
If handled improperly, compressed air can be dangerous.
Operating Environment
Warning
1. Do not use in an atmosphere containing corrosive
gases, chemicals, sea water, water, water steam, or
where there is direct contact with any of these.
2. Do not expose the product to direct sunlight for an
extended period of time.
3. Do not use in a place subject to heavy vibration and/
or shock.
4. Do not mount the product in locations where it is
exposed to radiant heat.
5. Products compliant with IP 6 5 satisfy the product
specifications when mounted properly. Be sure to
read the precautions for each product.
57
EXA1 Series
Specific Product Precautions 1
Be sure to read this before handling the products. Refer to the back cover for safety
instructions. For common precautions, refer to the “Operation Manual” on the SMC
website: https://www.smc.eu
Warning Caution
1. Do not use beyond the specification range. 1. Provide grounding to improve noise immunity.
Using beyond the specification range may result in a fire, Perform the dedicated grounding separate from the inverter of
malfunction, or damage to the system. the drive system and minimise the grounding distance from the
Check the specifications before operation. product.
2. Avoid repeatedly bending or stretching the cable and
applying heavy objects or force to it.
Caution Wiring where repeated bending and tensile stress are applied
1. When applicable to UL, use a Class 2 power supply to the cable may result in circuit breakage.
unit which is UL 1 3 1 0 compliant for direct current
3. Avoid miswiring.
power supply.
If miswired, there is a danger of malfunction or damage to the
2. Use within the specified voltage range. product.
Using beyond the specified voltage range is likely to cause
4. Do not wire while energising the product.
damage product or malfunction.
There is a danger of malfunction or damage to the product or
3. Do not remove the name plate. input/output device.
Improper maintenance or incorrect use of the Operation
5. Avoid wiring the power line and high-voltage line in
Manual may lead to equipment failure or malfunction. Also,
parallel.
there is a risk of losing conformity with safety standards.
Signal line noise or surge from the power line or high-pressure
4. Beware of inrush currents when the power supply is line could cause a malfunction.
turned on. Wiring of the product or input/output device and the power line
Some connected loads can apply an initial charge current or high-voltage line should be separated from each other.
which will trigger the over current protection function, causing
6. Check the wiring insulation.
the product to malfunction.
Defective insulation (contact with other circuits, improper
insulation between terminals, etc.) may cause damage to the
product or input/output device due to excessive voltage or
Mounting current.
58
EXA1 Series
Specific Product Precautions 2
Be sure to read this before handling the products. Refer to the back cover for safety
instructions. For common precautions, refer to the “Operation Manual” on the SMC
website: https://www.smc.eu
Warning Warning
1. Do not use in atmospheres containing inflammable 1. Do not perform operation or setting with wet hands.
or explosive gases. There is a risk of electrical shock.
Use in such atmospheres is likely to cause a fire or explosion.
This product is not explosion proof.
Caution
1. Use a watchmaker’s screwdriver with a thin blade
Caution for the setting switch.
1. Provide adequate protection when operating in When setting the switch, do not touch any unrelated parts.
locations such as the following. This may cause parts damage or malfunction due to a short
Failure to do so may cause a malfunction or equipment failure. circuit.
The effect of countermeasures should be checked in individual 2. Perform appropriate setting for the operating
equipment and machines. conditions.
1) Where noise is generated by static electricity, etc. Failure to do so could result in malfunction.
2) Where there is a strong electric field Refer to the Operation Manual for details on setting each
3) Where there is a danger of exposure to radiation switch.
4) When in close proximity to power lines or high-voltage lines 3. For details on programming and address setting,
2. Do not use in environments where oil and chemicals refer to the manual from the PLC manufacturer.
are used. The programming content related to the protocol is designed
Operating in environments where coolants, cleaning solvents, by the manufacturer of the PLC used.
various oils, or chemicals are present may cause adverse
effects (damage, malfunction, etc.) to the product even within a
short period of time.
3. Do not use in environments where the product could
be exposed to corrosive gases or liquids.
Use in such environments may cause product damage or
malfunction.
4. Do not use in locations with sources of surge
generation.
Installation of the product in an area around equipment
(electromagnetic lifters, high-frequency induction furnaces,
welding machines, motors, etc.) which generates large surge
voltages could cause an internal circuitry element of the
product to deteriorate or result in damage. Implement
countermeasures against the surge from the generating
source, and avoid contact between the lines.
5. The product is CE marked but not immune to
lightning strikes. Take measures against lightning
strikes in your system.
6. Keep dust, wire scraps, and other foreign matter
from entering the product.
Such materials may cause equipment failure or malfunction.
7. Do not use in places where there are cyclic tem-
perature changes.
When the cyclic temperature exceeds normal temperature
changes, the internal product is likely to be adversely affected.
59
ITV2050 to 3050-X399
Specific Product Precautions
Be sure to read this before handling the products. Refer to the back cover for safety
instructions. For common precautions, refer to the “Operation Manual” on the SMC
website: https://www.smc.eu
Handling
Caution
1. If the power supply to this product is turned off due
to a power failure during operation, the output on
the secondary side depends on the specifications.
Normally closed specification:
The output pressure is held.
Normally open specification:
Supply pressure minus 0.1 MPa or more pressure continues to
flow out.
2. If supply pressure to this product is interrupted or
shut off, while the power is still on, the internal
solenoid valve will continue to operate and a
humming noise will be generated.
Since it may greatly affect the life of the built-in
solenoid valve, when shutting off the supply
pressure, turn off the power of this product or set
the solenoid valve stop time.
3. This product is adjusted for each specification at
the time of shipment from the factory. Avoid
careless disassembly or removal of parts, as failure
to do so may result in a malfunction.
4. When connecting the cable to this product, turn the
lock ring of the cable. If a portion other than the
lock ring of the cable is turned, it may damage the
connector on the body. Turn the lock ring by hand
without using a tool.
5. The right angle cable does not rotate and is limited
to only one entry direction. If the right angle cable is
rotated forcibly, the cable may be broken or
damaged, or may damage the connector on the
body.
6. Specifications on page 2 4 are in case of static
environment. Pressure may fluctuate when air is
consumed at the output side.
60
AR20S to 50S Series
Specific Product Precautions 1
Be sure to read this before handling the products. Refer to the back cover for safety
instructions. For common precautions, refer to the “Operation Manual” on the SMC
website: https://www.smc.eu
Warning Warning
1. Provide ventilation when using this product in a 1. Set the regulator while verifying the displayed
confined area, such as in a closed control panel. values of the inlet and outlet pressure gauges.
For example, install a ventilation opening, etc., in Turning the regulator knob excessively can cause
order to prevent pressure from increasing inside of damage to the internal parts.
the confined area and to release the heat generated 2. Do not use tools on the pressure regulator knob as
by this product. this may cause damage. It must be operated
2. Polyacetal resin parts are used for the exterior. manually.
Organic solvents including thinner, acetone,
alcohol and ethylene chloride; chemicals including
sulphuric acid, nitric acid and hydrochloric acid; Caution
cutting oil, synthetic oils, ester-based compressor 1. When setting the pressure, the inlet pressure must
oil, alkali, kerosene, gasoline, lock material of be supplied after the pilot valve is powered.
screw are harmful. Do not use the product where
these are present. 2. Be sure to unlock the knob before adjusting the
pressure and lock it after setting the pressure.
Failure to follow this procedure can cause damage
Caution to the knob and the outlet pressure may fluctuate.
• Pull the pressure regulator knob to unlock. (You can visually
1. Pay attention to the leakage voltage. Particularly when verify this with the “orange mark” that appears in the gap.)
using a C-R element (surge voltage suppressor) to • Push the pressure regulator knob to lock. When the knob is
protect the switching element, take note that leakage not easily locked, turn it left and right a little and then push it
current will flow through the C-R element, thus (when the knob is locked, the “orange mark”, i.e., the gap
increasing leakage voltage. will disappear).
Switching element
OFF
Knob
C R
Leakage
voltage
Power
supply Valve
Leakage current
Orange mark
61
AR20S to 50S Series
Specific Product Precautions 2
Be sure to read this before handling the products. Refer to the back cover for safety
instructions. For common precautions, refer to the “Operation Manual” on the SMC
website: https://www.smc.eu
Wiring
Warning
1. The solenoid valve is an electrical product. For
safety, install an appropriate fuse and circuit
breaker before use.
Operating Environment
Warning
1. When the solenoid valve is mounted in a control
panel or it’s energised for a long period of time,
make sure the ambient temperature is within the
specifications of the valve.
Maintenance
Warning
1. Low-frequency operation
Valves should be operated at least once every 3 0 days to
prevent malfunction. (Use caution regarding the air supply.)
2. Manual override
When a manual override is operated, connected equipment
will be actuated. Operate only after safety is confirmed.
• Non-locking push type
Push down on the manual override with a small screwdriver,
etc., until it stops. Release the screwdriver and the manual
override will return.
• Push-turn locking lever type
When locking the manual override, be sure to push it down
before turning. Do not apply excessive torque as turning
without first pushing it down can cause damage to the manual
override and trouble such as air leakage. (0.1 N·m)
62
VP346E/546E/746E/946E-X660/X661
Specific Product Precautions 1
Be sure to read this before handling the products. Refer to the back cover for safety
instructions. For common precautions, refer to the “Operation Manual” on the SMC
website: https://www.smc.eu
Warning Caution
1. Resumption after a long period of holding time 1. Soft start-up function
When resuming operation after a long period of holding time, When the soft start-up function is selected, the initial pressure
there are cases in which, regardless of whether the product is of the pneumatic system can be increased gradually.
in an ON or OFF state, there is a delay in the initial response
time due to adhesion. Conducting several cycles of running-in Throttle Main valve Valve
1(P) 2(A)
3(R)
Caution P1
P1
an external peripheral device, the surge voltage protection When P2 reaches half of P1,
the main valve of the soft
element inside the valve is overloaded, causing the element start-up valve turns on.
to break. In the worst case, the breakage causes the electric
circuit to enter short-circuit status. If energising continues Soft start-up valve: ON
while in this state, a large current flows. This may cause Valve: ON
1/2 P1
P2
Piping
Caution
1. Silencer mounting Throttle valve
For handling of silencers, refer to the AN series/specific
product precautions.
Handling
Warning
1. Built-in check valve
A check valve is built into the pilot flow path to suppress the
pilot pressure drop due to pressure fluctuation on the inlet side.
When replacing pilot valve, please be careful for residual
pressure between check valve and pilot valve.
63
VP346E/546E/746E/946E-X660/X661
Specific Product Precautions 2
Be sure to read this before handling the products. Refer to the back cover for safety
instructions. For common precautions, refer to the “Operation Manual” on the SMC
website: https://www.smc.eu
Wiring
Warning
1. The solenoid valve is an electrical product. For
safety, install an appropriate fuse and circuit
breaker before use.
Operating Environment
Warning
1. When the solenoid valve is mounted in a control
panel or it’s energised for a long period of time,
make sure the ambient temperature is within the
specifications of the valve.
Maintenance
Warning
1. Low-frequency operation
Valves should be operated at least once every 3 0 days to
prevent malfunction. (Use caution regarding the air supply.)
2. Manual override
When a manual override is operated, connected equipment
will be actuated. Operate only after safety is confirmed.
64
These safety instructions are intended to prevent hazardous situations and/or equipment
Safety Instructions damage. These instructions indicate the level of potential hazard with the labels of
“Caution,” “Warning” or “Danger.” They are all important notes for safety and must be
followed in addition to International Standards (ISO/IEC) 1), and other safety regulations.
1) ISO 4414: Pneumatic fluid power – General rules relating to systems.
Caution indicates a hazard with a low level of risk
ISO 4413: Hydraulic fluid power – General rules relating to systems.
Caution: which, if not avoided, could result in minor or moderate IEC 60204-1: Safety of machinery – Electrical equipment of machines.
injury. (Part 1: General requirements)
Warning indicates a hazard with a medium level of risk ISO 10218-1: Manipulating industrial robots - Safety.
etc.
Warning: which, if not avoided, could result in death or serious
injury.
Danger indicates a hazard with a high level of risk
Danger: which, if not avoided, will result in death or serious
injury.
Safety Instructions Be sure to read “Handling Precautions for SMC Products” (M-E03-3) before using.
SMC Corporation (Europe)
Austria +43 (0)2262622800 www.smc.at office@smc.at Lithuania +370 5 2308118 www.smclt.lt info@smclt.lt
Belgium +32 (0)33551464 www.smc.be info@smc.be Netherlands +31 (0)205318888 www.smc.nl info@smc.nl
Bulgaria +359 (0)2807670 www.smc.bg office@smc.bg Norway +47 67129020 www.smc-norge.no post@smc-norge.no
Croatia +385 (0)13707288 www.smc.hr office@smc.hr Poland +48 222119600 www.smc.pl office@smc.pl
Czech Republic +420 541424611 www.smc.cz office@smc.cz Portugal +351 214724500 www.smc.eu apoioclientept@smc.smces.es
Denmark +45 70252900 www.smcdk.com smc@smcdk.com Romania +40 213205111 www.smcromania.ro smcromania@smcromania.ro
Estonia +372 651 0370 www.smcee.ee info@smcee.ee Russia +7 (812)3036600 www.smc.eu sales@smcru.com
Finland +358 207513513 www.smc.fi smcfi@smc.fi Slovakia +421 (0)413213212 www.smc.sk office@smc.sk
France +33 (0)164761000 www.smc-france.fr supportclient@smc-france.fr Slovenia +386 (0)73885412 www.smc.si office@smc.si
Germany +49 (0)61034020 www.smc.de info@smc.de Spain +34 945184100 www.smc.eu post@smc.smces.es
Greece +30 210 2717265 www.smchellas.gr sales@smchellas.gr Sweden +46 (0)86031240 www.smc.nu smc@smc.nu
Hungary +36 23513000 www.smc.hu office@smc.hu Switzerland +41 (0)523963131 www.smc.ch info@smc.ch
Ireland +353 (0)14039000 www.smcautomation.ie sales@smcautomation.ie Turkey +90 212 489 0 440 www.smcturkey.com.tr satis@smcturkey.com.tr
Italy +39 03990691 www.smcitalia.it mailbox@smcitalia.it UK +44 (0)845 121 5122 www.smc.uk sales@smc.uk
Latvia +371 67817700 www.smc.lv info@smc.lv
Printing AZ 00 Printed in Spain Specifications are subject to change without prior notice and any obligation on the part of the manufacturer