23 22 21 20 19 18 17 16 15 14 13 12 11
date
Up
1
A83
fast
travel /1.6
name
Down
thermistor register (drive)
2
Up /1.7
star/delta
3
Down /1.7
check
drawn
K31 forced switch off
3
4
fast /1.7
151 152 155 156
5
star/delta
date
K31
26.02.99
K35
K34
K33
K32
6
v 1/2 (LRV)
Zähl
name
N
4
S35
A1
/3.1 U1
voltage monitoring /3.2 Data Link
Ein/On
Aus/Off
U2
U3
U5
Landing Controll
N1
/3.4
5
electronic cabinet
A1
E1
project
A4
E4
/2.1.3 /2.4
order no
position indication Lift on Firemans Service
A5
E5
A7
E7
R4
- +
R5
/2.9 shield
LT
/2.9
Field bus LON
38098
LT
/2.9
Löschtaste
Terminal
TERM
8
ON OFF
of
unit
sheet:
9
0
10
1 2 3 4 5 6 7 8 9
202 24VDC
12A Floor level/ re-levelling/ impulse up
12B Floor level/ re-levelling/ impulse down
13A Correction up
13B Correction down
71 Door zone 1
34pol Ribbon cable 72 Door zone 2
plug connection
502 0VDC
ON MPK40-FKF 202 12A 12B 13A 13B 71 72 502 MPK40 IM40-01 A1 door 1 open R1 1 car call
1 2 3 4 Löschtaste Interfacemodul A2 door 1 close R2 2 car call
A3 door 2 open R3 3 car call
/5.3
/6.3
/6.4
/6.4
/6.4
/6.2
/6.2
/5.2
A2 A4 door 2 close R4 4 car call
A1 A2 A3 A4 A5 A6 A7 A8 R1 R2 R3 R4 R5 R6 R7 R8 A5 free selectable output R5 5 car call
A6 free selectable output R6 6 car call
A7 free selectable output R7 7 car call
/6.8
/6.8
/6.8
/5.2
/5.2
/6.9
/6.9
/6.9
/6.9
/6.9
A8 free selectable output R8 8 car call
/5.3
/5.4
/5.4
/5.4
E4 limitswitch door 1 closed D4 4 position indication
E5 photo-cell door 2 D5 5 position indication
60 60A 60B 63 260 202 502 502 D9 D10 TA1 TA2 202 202 502 502
E6 pressure contact door 2 D6 6 position indication
Terminal
E7 limitswitch door 2 open D7 7 position indication
TERM E8 limitswitch door 2 closed D8 8 position indication
/6.5
/6.5
/6.5
/6.5
/6.2
/6.7
/6.7
/6.6
/6.2
/6.2
/6.7
/6.7
ON OFF
60 Inspection 0-I D9 indicator up
201 501 LT LT LS 71 72 TE1 TE2 TE3 TE4 202 202 502 502
60A Inspection up D10 indicator down
60B Inspection down TA1 Overload indicator
63 Overload switch TA2 free selectable output
/6.8
/6.3
/6.3
/6.7
/6.7
/6.2
/6.2
/6.7
/6.7
/6.1
/6.1
/6.1
/6.1
K60F 11 K11 21
/6.4 /3.6
14 22
K12 62
/3.9
61
K13 53 61
/3.8
54 62
K36 11
/2.5
14
A83
/0.1 14 21
K33 K35
A83
up fast down fast Precontrol main contactors
Motor thermistor
15 22 151 155 156 152
A
N1 /3.9
PE /5.1
X1 L1 L2 L3 N PE U1 V1 W1 PE W2 U2 V2 PE 711 N1 712 PE 713 714 N1 151 150 152
Q2 2 4 6
B150 B153
1 3 5
F1A-F1C Y13 Y14 Y23 Y24
M
3~
M1
Supply up fast up slow down fast down slow
B150 Thermistor and/or thermal contact Motor
F1A-F1C Main fuses B153 monitor temperature maschineroom
M1 Drive motor valve S4 valve S1 valve S3 valve S2 ( if present )
Q2 Main switch A Terminals 155/156 are open; thermistor active
Giehl AZSTB-4MR =>K31 will forced switch off
contactor monitor/LRV
Voltage monitoring
Overload switch
3,15A
cabin ligth
+ 24V -
A1
+ - 200 E4 E5 E1 E7 E8 PE 500 207 R1 R2 R3 R4 R5 R6 R7 R8 507 501 201 LS LT LT
/0.1 24V/1,5A 24V/1,5A
S35 MPK 40 LON
Landing calls off MPK
BST electronic cabinet
A8 A1 E3 E2
Levelling/relevelling
BA+
Door zone 2
Door zone 1
safty circuit
valve control A70
/3.6 6 7 8 9 10 11 12 3 4 15 16
SM01-001
CE 0671
K36 A1 13
Prüf-Nr.: 0920892601/5 17 18
A2
/2.9 0V-Strg 0V-Strg /2.1.1
14 S12 3
11
12 /1.4
.8 4
.X1 A
S10 1 3 5 7 Handwinding switch
H12B H12
2 4 6 8
.6
/4.4
/4.5
S12 1 3 5 7
.X1 B
Q5 MCB phase protection device S10 Car light/emergency call 0-I 2 4 6 8 H12A Floor level indicator
.9
F5 Phase protection device G1 powersupply MPK F1 Saftey circuit fuse A63 overload device H12B Buzzer
remarks date name date name project titel unit
a Power Supply Control
drawn 26.02.99 Zähl
b
order no control no. sheet: 2
c OL 4329 38098
check of 10
d
1 2 3 4 5 6 7 8 9
H11
Shaft
24V 0V D1 D2
/0.1
K42A A1 BST
Binary-Code
15s A2 A2 A3 A4 A5 A6 A7
18
Liftcontroller
15
16 .6
8 24 34 37 44 5 15 25 35 45
10BK 9WH 10WH 8BK 11WH 12WH 13WH 14WH 15WH 16WH
8 24 34 37 44 5 15 25 35 45
13A /6.3
13B /6.3
TA1 /6.6
24V-Kab /6.6
Car
0V-Kab /6.6
42A 42A /5.1
.X11 SP1 SP2 D13 D14 .X11 202 502
V41A 41A /5.1 H1
Loud speaker D1 D2 24V 0V
V40A 40A /5.1
Inspection down
Terminal limit down
Pipe rupture valve
Inspection 0-I
Inspection up
Overspeed contact
Terminal limit up
Minimum pressure
Safety gear
Car gate 2
emergency stop
Car gate 1
locks 1..n
Clamp bridge
landig
present
X11 14E
Unsed
S6A
21 .1 32 24 .1 24 .2 24 .1 52
S6B
S7
.1 41
S3
S2C
S2A
S04
S05
S2B
X11 1E 2E 3E 4E 5E 8E 9E 10E 11E 13E 12E 20E 22E 24E
S1D
S1B
6 17 16 26 7 36 46
W40 1BK 7BK 2BK 3BK 6BK 4BK 5BK
/0.2.1
6 17 16 26 7 36 46
1A 1B 2A 2B 3B 4B 1C 2C 3C 4C 1D 6D
X1 1 2 3 3A 4 5 6 6A 7
/2.9 1 1 /5.1
A70
/2.7
1
K71 K72 K74 K73 2
/1.9 7
A1
U1 U2 U3 U4 U5 U6
/0.1
A83
U1 ~ U2 ~ U3 ~ U4 ~ U5 ~ U6 ~ 11
= = = = = = MPK 40 /0.1 K31 K32 K34
5V=
BST A83
intern
N N1 Precontrol main contactors 12 13 16 17 18 19 20
N1 A2 A2 A2
/2.9 N N /5.1 Inspection 0-I
1 2 1 2 1 2
S60 /1.2 /1.2 /1.3
13 23 31 41 51 61 N1 connections at the 3 4
/1.2 3 4
/1.2 3 4
/1.3
main contactors must not 5 6
/1.2 5 6
/1.2 5 6
/1.3
14 24 32 42 52 62 be altered 21 22 21 22 21 22
/1.5 .9 .8
.6
.6
.4
.7
/6.5
/6.5
53 54 53 54
/1.4
61 62 61 62
S60A 13 S60B 13 /1.5 /1.5
21 33 21 33
14 22 34 14 22 34
.7
.7
/6.5
/6.5
/6.5
/6.5
S10 2 6
Liftcontroller
/2.6 1 5
/2.9 BA+
/2.9 BA-
G90
/2.6 1 2 11 12 9 10 8 +
KNSG-100 12V
-6 +
13 14 15 16 7 -
F90 S90B
H90
Shaft
Supply
38 48 13 23 33 32 42 4 43 14
W40 13BK 14BK 3WH 4WH 5WH GN YE 7WH 6WH 8WH
/0.2.1
38 48 13 23 33 32 42 4 43 14
X11 PE L5 N4 101 102 103
Phone conectors
Car
S31 13 S30
X31 14
/3.1 1
to check the PE-conection
seperate conection and check for gateway
to safety circuit
10 30 50 9
s. Blatt 3.8
W40 16BK 17BK 18BK 15BK GNYE GNYE
/0.2.1
10 30 50 9
X11 L11 L12 L13 N PE
X11 20E 22E
Door
FKF Interfacemodul S40D 1 0 2
13 23
open close 0V 24V
A1 A2 502 E1 202 E2 E3 E4 14 24
.X11 41D
/2.1.4 41A
.X11 40D
/2.1.4 40A
/2.1.2 42A
..X11 202
W41 1 4 GNYE 5 6
Car
W42 GN BN YE GY WH PK BU RD
N40A
X40A
K41A 21 K40A 21
NC
N
PE
L11
42
202
202
202
202
COM
46
47
49
.2 .2
22 22
K40A A1 K41A A1
A2 A2
21 22 21 22
.2 .2 .2
31 32 31 32
14 44
Photo-cell
43 44 43 44
K41A 13 44
.1 .2
reopen
.2
14 43
X12 5 4 3
Door 1 Door 2
remarks date name date name project titel unit
a Querverweise, Kl 202 03.03.00 Zähl Door Controller
drawn 26.02.99 Zähl
b
order no control no. sheet: 5
c OL 4329 38098
check of 10
d
1 2 3 4 5 6 7 8 9
24V-Strg .X1 200
/2.1.9
/2.9 71
/2.9 72
/2.9 501 S60F
/2.9 201
/2.9 LON
.X1 60F
K60F A1
31 41 1 11 3 2 A2 47
/2.1.9 0V-Strg
+24V= Car
W40 WH BN RD BU 2WH 1WH 14 9BK /2.1.9 24V-Kab
0V Car
/0.2.1
12
11
/1.4 /2.1.9 0V-Kab
31 41 1 11 3 2 /5.6 60C 47
S60 61 13
S43A S44A S39
MS1 MS2 MS3 MS4 MS5 MS6
/3.1 62 14
Car calls
1-8
S60C 13
14
1 2 3 4 5 6 7
Voltage Supply FKF
Car preference
Car
.X11 13A
/2.1.9 13A .X11 13B S60B 31 13
/2.1.9 13B
Correction down
/3.2 32 14
Floor level up
Correction up
Door zone 2
Door zone 1
Pulse down
Pulse up
V60
X11 260 60 60A 60B 202 502
/2.1.9 TA1
A2
LT LT 201 501 72 71 202 502 71 72 12A 12B 13A 13B 260 60 60A 60B TA1 202 502 TE1 TE2 TE3 R1 R2 R3 R4 R5 R6 R7 R8
/0.1.1
FKF FKF Interfacemodul
elektronic car
Floor 1. 2. 3. 4. 5. n.
R G R G R G R G R G R G
S71
R G R G R G R G R G R G
S72
max. max. max. max. max. max. max. max. max. max. max. max.
25cm 25cm 25cm 25cm 25cm 25cm 25cm 25cm 25cm 25cm 25cm 25cm
R G R G R G R G R G R G R G R G R G R G
S12A
R G R G R G R G R G R G R G R G R G R G
S12B
R
S13A
G
S13B
S60F
Schematic layout Only if present magnetic switches: 12A Attention ! Count and level pulses
not to be scaled R =magnet, red front (south pole) Please note, the directional signals may not overlap
G =magnet, green front (north pole) for v-fast may not overlap! - min. 100ms pulsetime
S12A Impulse/ floor level up S71 Door zone 1 - min. 100ms pulse distance between
12B two pulses in the same direction.
S12B Impulse/ floor level down S72 Door zone 2
S13A Correction up S60F Inspection limit up
S13B Correction down pulsetime pulse pulsetime contact contact not contact
distance operated operated operated
R G R G
Terminal number
Wire number
14 X31 E31
S60A 13 31
S60A 24 S60B 24
14 32
S60B 31 13
23 23
32 14
X11 2E 3E 14E 10E 11E 12E 13E 260 60 60A 60B 49A 41D 40D 47A 49B 41E 40E 47B L5 N4 PE
7 6 9 8 10 12 11 1 2 4 5 15 16 14 13 18 19 20 21 3 17 PE
Inspection down
Inspection down
Inspection run
Inspection 0-I
Inspection 0-I
Inspection 0-I
Inspection 0-I
Inspection up
Inspection up
if present
if present
#E31
S60A
S60A
S60C
S60B
S60B
S60
S60
S60
S60
X31
E31
S31
S4