Installation and operating instructions
Declaration of Conformity Konformitätserklärung
We, Grundfos, declare under our sole responsibility that the products Wir, Grundfos, erklären in alleiniger Verantwortung, dass die Produkte
TP, to which this declaration relates, are in conformity with these Council TP, auf die sich diese Erklärung bezieht, mit den folgenden Richtlinien
directives on the approximation of the laws of the EC member states: des Rates zur Angleichung der Rechtsvorschriften der EU-
– Machinery Directive (2006/42/EC). Mitgliedsstaaten übereinstimmen:
Standards used: EN 809: 1998 and EN 60204-1: 2006. – Maschinenrichtlinie (2006/42/EG).
– ATEX Directive (94/9/EC) (applies only to products with the ATEX Normen, die verwendet wurden: EN 809: 1998 und EN 60204-1:
mark on the nameplate). 2006.
Standards used: EN 13463-1: 2001 and EN 13463-5: 2003. – ATEX-Richtlinie (94/9/EG) (gilt nur für Produkte mit der ATEX-Kenn-
(Declaration of conformity and installation and operating instructions zeichnung auf dem Leistungsschild).
of the motor are enclosed.) Normen, die verwendet wurden: EN 13463-1: 2001 und
EN 13463-5: 2003. (Die Konformitätserklärung und Montage- und
Betriebsanleitung vom Motor sind beigefügt.)
2
Декларация о соответствии Megfelelőségi nyilatkozat
Мы, компания Grundfos, со всей ответственностью заявляем, Mi, a Grundfos, egyedüli felelősséggel kijelentjük, hogy a TP termékek,
что изделия TP, к которым относится настоящая декларация, amelyekre jelen nyilatkozik vonatkozik, megfelelnek az Európai Unió
соответствуют следующим Директивам Совета Евросоюза об tagállamainak jogi irányelveit összehangoló tanács alábbi előírásainak:
унификации законодательных предписаний стран-членов ЕС: – Gépek (2006/42/EK).
– Механические устройства (2006/42/ЕС). Alkalmazott szabványok: EN 809: 1998 és EN 60204-1: 2006.
Применявшиеся стандарты: EN 809: 1998 и EN 60204-1: 2006. – ATEX Direktíva (94/9/EK) (csak az ATEX jelzéssel ellátott
– Директива ATEX (94/9/EC) (действительно только для изделий termékekre vonatkozik).
с маркировкой ATEX на фирменной табличке с техническими Alkalmazott szabványok: EN 13463-1: 2001 és EN 13463-5: 2003.
данными). (A motor kezelési utasítása és megelelőségi nyilatkozata
Применявшиеся стандарты: EN 13463-1: 2001 и EN 13463-5: mellékelve.)
2003. (Заявление о соответствии и руководство по монтажу и
эксплуатации электродвигателя прилагаются.)
3
4
TP
Installation and operating instructions 6
Installatie- en bedieningsinstructies 64
Asennus- ja käyttöohjeet 80
Monterings- og driftsinstruktion 88
5
Original installation and operating instructions. 2. General
These instructions apply to TP pumps fitted with
CONTENTS Grundfos motors, type MMG. If the pump is fitted
1. Symbols used in this document - 6 with a motor make other than Grundfos, please note
2. General - 6 that the motor data may differ from the data stated in
these instructions.
3. Versions - 6
4. Delivery and handling - 6 3. Versions
4.1 Delivery - 6
4.2 Handling - 6 The TP pumps described in these instructions are
5. Applications - 7 available in two versions:
5.1 Pumped liquids - 7 • PN 10 (10 bar) and
6. Technical data - 7 • PN 25 (25 bar).
6.1 Ambient temperature - 7 See nameplates in fig. 1 and 2.
6.2 Liquid temperature - 7
6.3 Minimum inlet pressure - 7
6.4 Maximum inlet pressure - 7 TP 150-370/4-A-F-A-BBRE
6
The pump should be lifted by means of nylon straps 6. Technical data
and shackles, see fig. 3.
6.1 Ambient temperature
Maximum +40 °C.
7
7.2 Pipework 7.4 Foundation
Arrows on the pump housing show the direction of Grundfos recommends to install the pump on a
flow of liquid through the pump. concrete foundation which is heavy enough to
The pump is suitable for mounting in horizontal provide permanent and rigid support to the entire
pipes. pump. The foundation must be capable of absorbing
any vibration, normal strain or shock. As a rule of
Isolating valves should be fitted either side of the
thumb, the weight of the concrete foundation should
pump to avoid draining the system if the pump needs
be 1.5 times the weight of the pump.
to be cleaned or repaired.
Place the pump on the foundation and fasten it,
When installing the pipes, it must be ensured that the
see fig. 5.
pump housing is not stressed by the pipework.
The suction and discharge pipes must be of an
adequate size, taking the pump inlet pressure into
account.
To avoid sediment build-up, do not fit the pump at the
lowest point of the system.
Install the pipes so that air locks are avoided, A
especially on the suction side of the pump, see fig. 4.
C
TM00 2263 0195
•• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
•••••••••••••• ••••••••••••••
•••••••••••••• ••••••••••••••
•••••••••••••• ••••••••••••••
•••••••••••••• ••••••••••••••
•••••••••••••• ••••••••••••••
•••••••••••••• ••••••••••••••
•••••••••••••• ••••••••••••••
•••••••••••••• ••••••••••••••
•••••••••••••• ••••••••••••••
•••••••••••••• ••••••••••••••
•••••••••••••• ••••••••••••••
•••••••••••••• ••••••••••••••
8
7.5.2 Vibration dampers 8.1 Frequency converter operation
To prevent vibrations from being transmitted to the
Grundfos motors:
building, it is recommended to isolate the pump
foundation from buildings by means of vibration All three-phase Grundfos motors from frame size 90
dampers. In order to select the right vibration and up can be connected to a frequency converter.
damper, the following details are required: The connection of a frequency converter will often
• Forces transferred through the damper. have the effect that the motor insulation system is
loaded more and that the motor will be more noisy
• Motor speed. In the case of speed control, this
than during normal operation. In addition, large
must also be taken into account.
motors are loaded by bearing currents caused by the
• Desired dampening in % (recommended value frequency converter.
70 %).
In the case of frequency converter operation, the
The selection of vibration damper differs from following should be considered:
installation to installation. A wrong damper may in
• In 2- and 4-pole motors of 110 kW and up and
certain cases increase the vibration level. Vibration
6-pole motors of 75 kW and up, one of the motor
dampers should therefore be sized by the supplier.
bearings should be electrically isolated to prevent
If the pump is installed on a foundation with vibration damaging currents from passing through the
dampers, expansion joints must be fitted on both motor bearings.
sides of the pump. This is very important to ensure
• In the case of noise critical applications, the motor
that the pump is not "hanging" from the flanges.
noise can be reduced by fitting a dU/dt filter
between the motor and the frequency converter. In
8. Electrical connections particularly noise critical applications, it is
The electrical connections should be carried out by recommended to fit a sinusoidal filter.
an authorized electrician in accordance with local • The length of the cable between motor and
regulations. frequency converter affects the motor load. It
should therefore be checked that the cable length
Warning meets the specifications laid down by the
Before removing the terminal box cover frequency converter supplier.
and before any removal/dismantling of • For supply voltages between 500 and 690 V,
the pump, make sure that the electricity either a dU/dt filter should be fitted to reduce
supply has been switched off. voltage peaks or a motor with reinforced insulation
The pump must be connected to an should be used.
external mains switch. • For supply voltages of 690 V, a motor with
The operating voltage and frequency are marked on reinforced insulation should be used and a dU/dt
the nameplate. Make sure that the motor is suitable filter should be fitted.
for the electricity supply on which it will be used. Other motor makes than Grundfos:
The motor must be connected to a motor starter. Please contact Grundfos or the motor manufacturer.
Motors of 3 kW and up incorporate thermistors
(PTC). The thermistors are designed according to
DIN 44082. The motor starter and the thermistors
must be connected in series. Consequently, the
motor will not be started until it has cooled to normal
temperature.
The terminal box can be turned in 30 ° or 45 ° steps,
depending on pump size.
Remove the bolts securing the motor to the pump.
Turn the motor to the required position. Replace and
tighten the bolts.
The electrical connection should be carried out as
shown in the diagram inside the terminal box cover.
9
9. Start-up 9.2 Checking the direction of rotation
Do not start the pump to check the direction of
Do not start the pump until it has been rotation until it has been filled with liquid.
Caution
filled with liquid and vented.
The correct direction of rotation is indicated by
arrows on the pump.
9.1 Priming
Closed systems or open systems where the 9.3 Starting
liquid level is above the pump inlet: 1. Before starting the pump, completely open the
1. Close the discharge isolating valve and loosen isolating valve on the suction side of the pump
the air vent screw in the motor stool, see fig. 6. and leave the discharge isolating valve almost
closed.
Warning 2. Start the pump.
Pay attention to the direction of the 3. Vent the pump during starting by loosening the air
vent hole and take care to ensure that vent screw in the motor stool until a steady
the escaping water does not cause stream of liquid runs out of the vent hole, see
injury to persons or damage to the fig. 6.
motor or other components. In hot-
water installations, special attention Warning
should be paid to the risk of injury Pay attention to the direction of the
caused by scalding hot water. vent hole and take care to ensure that
the escaping water does not cause
injury to persons or damage to the
motor or other components.
In hot-water installations, special
attention should be paid to the risk of
injury caused by scalding hot water.
Air vent screw 4. When the piping system has been filled with
TM02 6967 2003
10
10. Maintenance 11. Frost protection
Pumps which are not being used during periods of
Warning frost should be drained to avoid damage.
Before starting work on the pump, Drain the pump by loosening the air vent screw in the
make sure that the electricity supply motor stool and by removing the drain plug from the
has been switched off and that it cannot pump housing, see fig. 7.
be accidentally switched on.
Warning
10.1 Pump Care must be taken to ensure that the
The pump is maintenance-free. escaping water does not cause injury to
If the pump is to be drained for a long period of persons or damage to the motor or
inactivity, inject a few drops of silicone oil on the other components.
shaft between the motor stool and the coupling. In hot water installations, special
This will prevent the shaft seal faces from sticking. attention should be paid to the risk of
injury caused by scalding hot water.
10.2 Motor
The motor should be checked at regular intervals.
It is important to keep the motor clean in order to
ensure adequate ventilation. If the pump is installed
in a dusty environment, the pump must he cleaned
and checked regularly.
Lubrication:
The bearings of motors up to 11 kW are greased for
life and require no lubrication.
11
12. Fault finding chart
Warning
Before removing the terminal box cover and before any removal/dismantling of the pump,
make sure that the electricity supply has been switched off and that it cannot be accidentally
switched on.
Fault Cause
1. Motor does not run when a) Supply failure.
started. b) Fuses blown.
c) Motor starter overload has tripped out.
d) Main contacts in motor starter are not making contact or the coil is
faulty.
e) Control circuit fuses are defective.
f) Motor is defective.
2. Motor starter overload trips a) One fuse is blown.
out immediately when supply b) Contacts in motor starter overload are faulty.
is switched on. c) Cable connection is loose or faulty.
d) Motor winding is defective.
e) Pump mechanically blocked.
f) Overload setting too low.
3. Motor starter overload trips a) Overload setting too low.
out occasionally. b) Supply voltage periodically too low or too high.
c) Differential pressure across pump too low, see section 9.3 Starting.
4. Motor starter has not tripped a) Supply failure.
out but the pump does not b) Fuses blown.
run. c) Main contacts in motor starter are not making contact or the coil is
faulty.
d) Control circuit fuses are defective.
5. Pump capacity not constant. a) Pump inlet pressure is too low.
b) Suction pipe/pump partly blocked by impurities.
c) Pump draws in air.
6. Pump runs but gives no water. a) Suction pipe/pump blocked by impurities.
b) Foot or non-return valve blocked in closed position.
c) Leakage in suction pipe.
d) Air in suction pipe or pump.
e) Motor rotates in the wrong direction.
7. Pump runs backwards when a) Leakage in suction pipe.
switched off. b) Foot or non-return valve defective.
c) Foot or non-return valve blocked in open or partly open position.
8. Leakage in shaft seal. a) Shaft seal is defective.
9. Noise. a) Pump is cavitating.
b) Pump does not rotate freely (frictional resistance) because of
incorrect pump shaft position.
c) Frequency converter operation:
See section 8.1 Frequency converter operation.
d) Resonance in the installation.
e) Foreign bodies in the pump.
10. Pump runs constantly a) The stop pressure has been set too high.
(applies only to pumps with b) The water consumption is larger than anticipated.
automatic start/stop). c) Leakage in discharge pipe.
d) The direction of rotation of the pump is incorrect.
e) Pipes, valves or strainer blocked by impurities.
f) Pump controller, if fitted, is defective.
11. Period of operation is too long a) The stop pressure has been set too high.
(applies only to pumps with b) Pipes, valves or strainer blocked by impurities.
automatic start/stop). c) Pump partly blocked or furred up.
d) The water consumption is larger than anticipated.
e) Leakage in discharge pipe.
12
13. Service
Warning
If a pump has been used for a liquid
which is injurious to health or toxic, the
pump will be classified as
contaminated.
If Grundfos is requested to service the pump,
Grundfos must be contacted with details about the
pumped liquid, etc. before the pump is returned for
service. Otherwise Grundfos can refuse to accept
the pump for service.
Possible costs of returning the pump are paid by the
customer.
However, any application for service (no matter to
whom it may be made) must include details about
the pumped liquid if the pump has been used for
liquids which are injurious to health or toxic.
14. Disposal
This product or parts of it must be disposed of in an
environmentally sound way:
1. Use the public or private waste collection service.
2. If this is not possible, contact the nearest
Grundfos company or service workshop.
Subject to alterations.
13
GB: Inlet pressure stated in bar relative pressure (pressure gauge value measured on the suction side of the
pump)
D: Zulaufdruck in bar Relativdruck (Manometerdruck auf der Saugseite der Pumpe gemessen)
F: Pression d’entrée indiquée en bar (valeur mesurée à l’aide d’un manomètre placé sur le côté aspiration
de la pompe)
I: Pressione di aspirazione indicata in bar (valore misurato con un manometro posto sul lato aspirazione
della pompa)
E: Presión de aspiración indicada en bar como presión relativa (valor del manómetro medido en la
aspiración de la bomba)
P: Pressão de entrada com a pressão relativa apresentada em bar (ponto de medida na parte de aspiração
da bomba)
GR: Πίεση αναρρόφησης σε bar σχετικής πίεσης (μετρούμενη τιμή πίεσης στην πλευρά αναρρόφησης της
αντλίας)
NL: Inlaatdruk weergegeven in bar relatieve druk (drukopnemer waarde, gemeten aan de zuigkant van de
pomp)
S: Tilloppstrycket angivet i bar relativt tryck (manometervärde mätt på pumpens sugsida)
FIN: Tulopaine ilmoitettuna baareina on suhteellinen paine (painemittarin lukema mitattu
pumpun imupuolella)
DK: Tilløbstrykket angivet i bar relativt tryk (manometerværdi målt på pumpens sugeside)
PL: Ciśnienie na króćcu ssawnym pompy wyrażone w barach (mierzone manometrem na stronie ssawnej
pompy)
RU: Давление на входе в барах (измерения производились во всасывающей части насоса)
H: Hozzáfolyási nyomás a szívóoldalon bar-ban, relatív nyomás értékben (szivattyú szívóoldali
nyomásmérőjén jelzett érték)
SI: Vhodni tlak v barih relativni tlak (izmerjena vrednost na sesalni strani črpalke)
HR: Ulazni tlak u barima relativnog tlaka (manometarski tlak izmjeren na usisnoj strani crpke)
YU: Ulazni pritisak je dat u barima relativnog pritiska (manometarska vrednost merena na usisnoj strani
pumpe)
RO: Presiunea de intrare exprimată în bar ca presiune relativă (valoarea masurată de manometru pe partea
de aspiraţie a pompei)
BG: Относително входно налягане в bar (стойност на манометъра в смукателната страна на помпата)
CZ: Tlak na sání vyjádřený v barech je relativní tlak (hodnota na manometru měřená na sací straně čerpadla)
SK: Vstupný tlak uvedený v baroch relatívneho tlaku (hodnota na manometru meraná na sacej strane
čerpadla)
TR: Bar olarak belirtilen nispi basınç giriş basıncı (pompanın emme kısmındaki basınç ölçü değeri)
197
50 Hz, 4-pole, PN 10
60 Hz, 4-pole, PN 10
198
50 Hz, 2-pole, PN 25
50 Hz, 4-pole, PN 25
199
Pump type p [bar]
60 Hz, 2-pole, PN 25
200
60 Hz, 4-pole, PN 25
201
Maximum sound pressure level
50 Hz 60 Hz
Three-phase motors [dB(A)] [dB(A)]
[kW]
2-pole 4-pole 2-pole 4-pole
5.5 58 62
7.5 58 62
11 60 64
15 60 64
18.5 61 65
22 61 65
30 69 62 66
37 69 65 69
45 72 65 69
55 74 65 78 69
75 76 69 80 73
90 76 69 80 73
110 78 70 82 74
132 78 70 82 74
160 78 70 82 74
200 78 70 82 74
250 82 73 86 77
315 73 77
355 75
400 75
500 75
560 78
630 78
202
Argentina Estonia Latvia Slovenia
Bombas GRUNDFOS de Argentina S.A. GRUNDFOS Pumps Eesti OÜ SIA GRUNDFOS Pumps Latvia GRUNDFOS PUMPEN VERTRIEB
Ruta Panamericana km. 37.500 Lote 34A Peterburi tee 92G Deglava biznesa centrs Ges.m.b.H.,
1619 - Garin 11415 Tallinn Augusta Deglava ielā 60, LV-1035, Rīga, Podružnica Ljubljana
Pcia. de Buenos Aires Tel: + 372 606 1690 Tālr.: + 371 714 9640, 7 149 641 Šlandrova 8b, SI-1231 Ljubljana-Črnuče
Phone: +54-3327 414 444 Fax: + 372 606 1691 Fakss: + 371 914 9646 Phone: +386 1 568 0610
Telefax: +54-3327 411 111 Telefax: +386 1 568 0619
Finland Lithuania
E-mail: slovenia@grundfos.si
Australia OY GRUNDFOS Pumput AB GRUNDFOS Pumps UAB
GRUNDFOS Pumps Pty. Ltd. Mestarintie 11 Smolensko g. 6 Spain
P.O. Box 2040 FIN-01730 Vantaa LT-03201 Vilnius Bombas GRUNDFOS España S.A.
Regency Park Phone: +358-3066 5650 Tel: + 370 52 395 430 Camino de la Fuentecilla, s/n
South Australia 5942 Telefax: +358-3066 56550 Fax: + 370 52 395 431 E-28110 Algete (Madrid)
Phone: +61-8-8461-4611 Tel.: +34-91-848 8800
France Malaysia
Telefax: +61-8-8340 0155 Telefax: +34-91-628 0465
Pompes GRUNDFOS Distribution S.A. GRUNDFOS Pumps Sdn. Bhd.
Austria Parc d’Activités de Chesnes 7 Jalan Peguam U1/25 Sweden
GRUNDFOS Pumpen Vertrieb Ges.m.b.H. 57, rue de Malacombe Glenmarie Industrial Park GRUNDFOS AB
Grundfosstraße 2 F-38290 St. Quentin Fallavier (Lyon) 40150 Shah Alam Box 333 (Lunnagårdsgatan 6)
A-5082 Grödig/Salzburg Tél.: +33-4 74 82 15 15 Selangor 431 24 Mölndal
Tel.: +43-6246-883-0 Télécopie: +33-4 74 94 10 51 Phone: +60-3-5569 2922 Tel.: +46(0)771-32 23 00
Telefax: +43-6246-883-30 Telefax: +60-3-5569 2866 Telefax: +46(0)31-331 94 60
Germany
Belgium GRUNDFOS GMBH México Switzerland
N.V. GRUNDFOS Bellux S.A. Schlüterstr. 33 Bombas GRUNDFOS de México S.A. de GRUNDFOS Pumpen AG
Boomsesteenweg 81-83 40699 Erkrath C.V. Bruggacherstrasse 10
B-2630 Aartselaar Tel.: +49-(0) 211 929 69-0 Boulevard TLC No. 15 CH-8117 Fällanden/ZH
Tél.: +32-3-870 7300 Telefax: +49-(0) 211 929 69-3799 Parque Industrial Stiva Aeropuerto Tel.: +41-1-806 8111
Télécopie: +32-3-870 7301 e-mail: infoservice@grundfos.de Apodaca, N.L. 66600 Telefax: +41-1-806 8115
Service in Deutschland: Phone: +52-81-8144 4000
Belorussia Taiwan
e-mail: kundendienst@grundfos.de Telefax: +52-81-8144 4010
Представительство ГРУНДФОС в GRUNDFOS Pumps (Taiwan) Ltd.
Минске Greece Netherlands 7 Floor, 219 Min-Chuan Road
220123, Минск, GRUNDFOS Hellas A.E.B.E. GRUNDFOS Netherlands Taichung, Taiwan, R.O.C.
ул. В. Хоружей, 22, оф. 1105 20th km. Athinon-Markopoulou Av. Veluwezoom 35 Phone: +886-4-2305 0868
Тел.: +(37517) 233 97 65, P.O. Box 71 1326 AE Almere Telefax: +886-4-2305 0878
Факс: +(37517) 233 97 69 GR-19002 Peania Postbus 22015
Thailand
E-mail: grundfos_minsk@mail.ru Phone: +0030-210-66 83 400 1302 CA ALMERE
GRUNDFOS (Thailand) Ltd.
Telefax: +0030-210-66 46 273 Tel.: +31-88-478 6336
Bosnia/Herzegovina 92 Chaloem Phrakiat Rama 9 Road,
Telefax: +31-88-478 6332
GRUNDFOS Sarajevo Hong Kong Dokmai, Pravej, Bangkok 10250
e-mail: info_gnl@grundfos.com
Trg Heroja 16, GRUNDFOS Pumps (Hong Kong) Ltd. Phone: +66-2-725 8999
BiH-71000 Sarajevo Unit 1, Ground floor New Zealand Telefax: +66-2-725 8998
Phone: +387 33 713 290 Siu Wai Industrial Centre GRUNDFOS Pumps NZ Ltd.
Turkey
Telefax: +387 33 659 079 29-33 Wing Hong Street & 17 Beatrice Tinsley Crescent
GRUNDFOS POMPA San. ve Tic. Ltd. Sti.
e-mail: grundfos@bih.net.ba 68 King Lam Street, Cheung Sha Wan North Harbour Industrial Estate
Gebze Organize Sanayi Bölgesi
Kowloon Albany, Auckland
Brazil Ihsan dede Caddesi,
Phone: +852-27861706 / 27861741 Phone: +64-9-415 3240
Mark GRUNDFOS Ltda. 2. yol 200. Sokak No. 204
Telefax: +852-27858664 Telefax: +64-9-415 3250
Av. Humberto de Alencar Castelo Branco, 41490 Gebze/ Kocaeli
630 Hungary Norway Phone: +90 - 262-679 7979
CEP 09850 - 300 GRUNDFOS Hungária Kft. GRUNDFOS Pumper A/S Telefax: +90 - 262-679 7905
São Bernardo do Campo - SP Park u. 8 Strømsveien 344 E-mail: satis@grundfos.com
Phone: +55-11 4393 5533 H-2045 Törökbálint, Postboks 235, Leirdal
Ukraine
Telefax: +55-11 4343 5015 Phone: +36-23 511 110 N-1011 Oslo
ТОВ ГРУНДФОС УКРАЇНА
Telefax: +36-23 511 111 Tlf.: +47-22 90 47 00
Bulgaria 01010 Київ, Вул. Московська 8б,
Telefax: +47-22 32 21 50
GRUNDFOS Pumpen Vertrieb India Тел.:(+38 044) 390 40 50
Representative Office - Bulgaria GRUNDFOS Pumps India Private Limited Poland Фах.: (+38 044) 390 40 59
Bulgaria, 1421 Sofia 118 Old Mahabalipuram Road GRUNDFOS Pompy Sp. z o.o. E-mail: ukraine@grundfos.com
Lozenetz District Thoraipakkam ul. Klonowa 23
United Arab Emirates
105-107 Arsenalski blvd. Chennai 600 096 Baranowo k. Poznania
GRUNDFOS Gulf Distribution
Phone: +359 2963 3820, 2963 5653 Phone: +91-44 2496 6800 PL-62-081 Przeźmierowo
P.O. Box 16768
Telefax: +359 2963 1305 Tel: (+48-61) 650 13 00
Indonesia Jebel Ali Free Zone
Fax: (+48-61) 650 13 50
Canada PT GRUNDFOS Pompa Dubai
GRUNDFOS Canada Inc. Jl. Rawa Sumur III, Blok III / CC-1 Portugal Phone: +971-4- 8815 166
2941 Brighton Road Kawasan Industri, Pulogadung Bombas GRUNDFOS Portugal, S.A. Telefax: +971-4-8815 136
Oakville, Ontario Jakarta 13930 Rua Calvet de Magalhães, 241
United Kingdom
L6H 6C9 Phone: +62-21-460 6909 Apartado 1079
GRUNDFOS Pumps Ltd.
Phone: +1-905 829 9533 Telefax: +62-21-460 6910 / 460 6901 P-2770-153 Paço de Arcos
Grovebury Road
Telefax: +1-905 829 9512 Tel.: +351-21-440 76 00
Ireland Leighton Buzzard/Beds. LU7 8TL
Telefax: +351-21-440 76 90
China GRUNDFOS (Ireland) Ltd. Phone: +44-1525-850000
GRUNDFOS Pumps (Shanghai) Co. Ltd. Unit A, Merrywell Business Park România Telefax: +44-1525-850011
51 Floor, Raffles City Ballymount Road Lower GRUNDFOS Pompe România SRL
U.S.A.
No. 268 Xi Zang Road. (M) Dublin 12 Bd. Biruintei, nr 103
GRUNDFOS Pumps Corporation
Shanghai 200001 Phone: +353-1-4089 800 Pantelimon county Ilfov
17100 West 118th Terrace
PRC Telefax: +353-1-4089 830 Phone: +40 21 200 4100
Olathe, Kansas 66061
Phone: +86-021-612 252 22 Telefax: +40 21 200 4101
Italy Phone: +1-913-227-3400
Telefax: +86-021-612 253 33 E-mail: romania@grundfos.ro
GRUNDFOS Pompe Italia S.r.l. Telefax: +1-913-227-3500
Croatia Via Gran Sasso 4 Russia
Usbekistan
GRUNDFOS CROATIA d.o.o. I-20060 Truccazzano (Milano) ООО Грундфос
Представительство ГРУНДФОС в
Cebini 37, Buzin Tel.: +39-02-95838112 Россия, 109544 Москва, ул. Школьная 39
Ташкенте
HR-10010 Zagreb Telefax: +39-02-95309290 / 95838461 Тел. (+7) 495 737 30 00, 564 88 00
700000 Ташкент ул.Усмана Носира 1-й
Phone: +385 1 6595 400 Факс (+7) 495 737 75 36, 564 88 11
Japan тупик 5
Telefax: +385 1 6595 499 E-mail grundfos.moscow@grundfos.com
GRUNDFOS Pumps K.K. Телефон: (3712) 55-68-15
www.grundfos.hr
Gotanda Metalion Bldg., 5F, Serbia Факс: (3712) 53-36-35
Czech Republic 5-21-15, Higashi-gotanda GRUNDFOS Predstavništvo Beograd
GRUNDFOS s.r.o. Shiagawa-ku, Tokyo Dr. Milutina Ivkovića 2a/29
Čajkovského 21 141-0022 Japan YU-11000 Beograd
779 00 Olomouc Phone: +81 35 448 1391 Phone: +381 11 26 47 877 / 11 26 47 496
Phone: +420-585-716 111 Telefax: +81 35 448 9619 Telefax: +381 11 26 48 340
Telefax: +420-585-716 299
Korea Singapore
Denmark GRUNDFOS Pumps Korea Ltd. GRUNDFOS (Singapore) Pte. Ltd.
GRUNDFOS DK A/S 6th Floor, Aju Building 679-5 24 Tuas West Road
Martin Bachs Vej 3 Yeoksam-dong, Kangnam-ku, 135-916 Jurong Town
DK-8850 Bjerringbro Seoul, Korea Singapore 638381
Tlf.: +45-87 50 50 50 Phone: +82-2-5317 600 Phone: +65-6865 1222
Telefax: +45-87 50 51 51 Telefax: +82-2-5633 725 Telefax: +65-6861 8402
E-mail: info_GDK@grundfos.com
www.grundfos.com/DK
96511031 0110
Repl. 96511031 0505
177
The name Grundfos, the Grundfos logo, and the payoff Be–Think–Innovate are registrated trademarks
owned by Grundfos Management A/S or Grundfos A/S, Denmark. All rights reserved worldwide.
www.grundfos.com